Literature DB >> 30895376

Comparison of invasive and noninvasive blood hemoglobin measurement in the operating room: a systematic review and meta-analysis.

Hosein Shabaninejad1, Nashmil Ghadimi2, Kourosh Sayehmiri3, Hossein Hosseinifard4, Rasoul Azarfarin5, Hasan Abolghasem Gorji1.   

Abstract

Noninvasive hemoglobin (Hb)-monitoring devices are new inventions in pulse oximeter systems that show hemoglobin levels continuously. The aim of this systematic review and meta-analysis was to evaluate the accuracy and precision of noninvasive versus standard central laboratory Hb measurements in the operating room. We systematically searched multiple databases. Then, for the quality assessment of studies, we modified QUADAS-2 in the Revman 5.3 software. The GRADE approach was used to measure the quality of evidence (Grading of Recommendations Assessment, Development, and Evaluation). Data were analyzed using the meta-analysis method (random effect model) using STATA 11 software. A total of 28 studies on 2000 participants were included in the meta-analysis. Meta-analysis results of mean differences between noninvasive and the central laboratory Hb measurements in overall pooled random effects were - 0.27 (95% LoA (0.44, - 0.10); P value < 0.05). According to this meta-analysis, noninvasive hemoglobin measurement has acceptable accuracy in comparison with the standard invasive method.

Entities:  

Keywords:  Hemoglobin; Measurement; Monitoring; Noninvasive; Pulse oximeter

Mesh:

Substances:

Year:  2019        PMID: 30895376     DOI: 10.1007/s00540-019-02629-1

Source DB:  PubMed          Journal:  J Anesth        ISSN: 0913-8668            Impact factor:   2.078


  45 in total

1.  Quantifying heterogeneity in a meta-analysis.

Authors:  Julian P T Higgins; Simon G Thompson
Journal:  Stat Med       Date:  2002-06-15       Impact factor: 2.373

Review 2.  Financial and clinical outcomes associated with surgical bleeding complications.

Authors:  Aryeh Shander
Journal:  Surgery       Date:  2007-10       Impact factor: 3.982

3.  Performance evaluation of a noninvasive hemoglobin monitoring device.

Authors:  Etienne Gayat; Antoine Bodin; Caroline Sportiello; Mireille Boisson; Jean-François Dreyfus; Emmanuel Mathieu; Marc Fischler
Journal:  Ann Emerg Med       Date:  2011-01-19       Impact factor: 5.721

4.  A comparison of three methods of hemoglobin monitoring in patients undergoing spine surgery.

Authors:  Ronald D Miller; Theresa A Ward; Stephen C Shiboski; Neal H Cohen
Journal:  Anesth Analg       Date:  2011-03-08       Impact factor: 5.108

5.  Validation of noninvasive hemoglobin measurements using the Masimo Radical-7 SpHb Station.

Authors:  Marlin Wayne Causey; Seth Miller; Andrew Foster; Alec Beekley; David Zenger; Matthew Martin
Journal:  Am J Surg       Date:  2011-05       Impact factor: 2.565

6.  Red blood cell transfusions and nosocomial infections in critically ill patients.

Authors:  Robert W Taylor; Jacklyn O'Brien; Steven J Trottier; Lisa Manganaro; Margaret Cytron; Mary F Lesko; Kimberly Arnzen; Carla Cappadoro; Min Fu; Michael S Plisco; Farid G Sadaka; Christopher Veremakis
Journal:  Crit Care Med       Date:  2006-09       Impact factor: 7.598

7.  Recent advances in pulse oximetry.

Authors:  Maxime Cannesson; Pekka Talke
Journal:  F1000 Med Rep       Date:  2009-08-26

8.  Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative.

Authors:  Patrick M Bossuyt; Johannes B Reitsma; David E Bruns; Constantine A Gatsonis; Paul P Glasziou; Les M Irwig; Jeroen G Lijmer; David Moher; Drummond Rennie; Henrica C W de Vet
Journal:  Clin Chem Lab Med       Date:  2003-01       Impact factor: 3.694

9.  Comparison and agreement between venous and arterial gas analysis in cardiopulmonary patients in Kashmir valley of the Indian subcontinent.

Authors:  Parvaiz A Koul; Umar Hafiz Khan; Abdul Ahad Wani; Rafiqa Eachkoti; Rafi A Jan; Sanaullah Shah; Zarka Masoodi; Syed Mudassir Qadri; Muneer Ahmad; Asrar Ahmad
Journal:  Ann Thorac Med       Date:  2011-01       Impact factor: 2.219

10.  Quantifying, displaying and accounting for heterogeneity in the meta-analysis of RCTs using standard and generalised Q statistics.

Authors:  Jack Bowden; Jayne F Tierney; Andrew J Copas; Sarah Burdett
Journal:  BMC Med Res Methodol       Date:  2011-04-07       Impact factor: 4.615

View more
  3 in total

1.  Accuracy of Continuous and Noninvasive Hemoglobin Monitoring in the Presence of CO2 Insufflation: An Observational Pilot Study.

Authors:  Hye Sun Lee; Ji Won Yoo; Ha Yeon Kim; Na Young Kim; Ji Eun Kim
Journal:  Med Sci Monit       Date:  2021-10-27

2.  Impact of Increased End-Tidal Carbon Dioxide on Continuous Noninvasive Hemoglobin Monitoring during Laparoscopic Gastrectomy: A Randomized Controlled Study.

Authors:  Ha-Yeon Kim; Jong-Bum Choi; Sang-Uk Han; Hye-Sun Lee; Kyuhyeok Lee; Ji-Eun Kim
Journal:  J Pers Med       Date:  2022-01-26

Review 3.  What is new in microcirculation and tissue oxygenation monitoring?

Authors:  Ilonka N de Keijzer; Dario Massari; Marko Sahinovic; Moritz Flick; Jaap Jan Vos; Thomas W L Scheeren
Journal:  J Clin Monit Comput       Date:  2022-03-11       Impact factor: 1.977

  3 in total