Literature DB >> 21705869

Assessing the diagnostic accuracy of pulse pressure variations for the prediction of fluid responsiveness: a "gray zone" approach.

Maxime Cannesson1, Yannick Le Manach, Christoph K Hofer, Jean Pierre Goarin, Jean-Jacques Lehot, Benoît Vallet, Benoît Tavernier.   

Abstract

BACKGROUND: Respiratory arterial pulse pressure variations (PPV) are the best predictors of fluid responsiveness in mechanically ventilated patients during general anesthesia. However, previous studies were performed in a small number of patients and determined a single cutoff point to make clinical discrimination. The authors sought to test the predictive value of PPV in a large, multicenter study and to express it using a gray zone approach.
METHODS: The authors studied 413 patients during general anesthesia and mechanical ventilation in four centers. PPV, central venous pressure, and cardiac output were recorded before and after volume expansion (VE). Response to VE was defined as more than 15% increase in cardiac output after VE. The following approaches were used to determine the gray zones: resampled and two-graph receiver operator characteristic curves. The impact of changes in the benefit-risk balance of VE on the gray zone was also evaluated.
RESULTS: The authors observed 209 responders (51%) and 204 nonresponders (49%) to VE. The area under receiver operating characteristic curve was 0.89 (95% CI: 0.86-0.92) for PPV, compared with 0.57 (95% CI: 0.54-0.59) for central venous pressure (P < 10). The gray zone approach identified a range of PPV values (between 9% and 13%) for which fluid responsiveness could not be predicted reliably. These PPV values were seen in 98 (24%) patients. Changes in the cost ratio of VE moderately affected the gray zone limits.
CONCLUSION: Despite a strong predictive value, PPV may be inconclusive (between 9% and 13%) in approximately 25% of patients during general anesthesia.

Entities:  

Mesh:

Year:  2011        PMID: 21705869     DOI: 10.1097/ALN.0b013e318225b80a

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  126 in total

1.  Visual estimation of pulse pressure variation is not reliable: a randomized simulation study.

Authors:  Joseph Rinehart; Tanzeem Islam; Rob Boud; Allison Nguyen; Brenton Alexander; Cecilia Canales; Maxime Cannesson
Journal:  J Clin Monit Comput       Date:  2012-04-11       Impact factor: 2.502

Review 2.  A Review of Cutoffs for Nutritional Biomarkers.

Authors:  Ramkripa Raghavan; Fayrouz Sakr Ashour; Regan Bailey
Journal:  Adv Nutr       Date:  2016-01-15       Impact factor: 8.701

3.  Agreement in hemodynamic monitoring during orthotopic liver transplantation: a comparison of FloTrac/Vigileo at two monitoring sites with pulmonary artery catheter thermodilution.

Authors:  Matthew Lee; Laurence Weinberg; Brett Pearce; Nicholas Scurrah; David A Story; Param Pillai; Peter R McCall; Larry P McNicol; Philip J Peyton
Journal:  J Clin Monit Comput       Date:  2016-02-16       Impact factor: 2.502

4.  Respiratory induced dynamic variations of stroke volume and its surrogates as predictors of fluid responsiveness: applicability in the early stages of specific critical states.

Authors:  Jan Benes; Jan Zatloukal; Jakub Kletecka; Alena Simanova; Lenka Haidingerova; Richard Pradl
Journal:  J Clin Monit Comput       Date:  2013-10-23       Impact factor: 2.502

5.  Frequency domain analysis of cerebral near infrared spectroscopy signals during application of an impedance threshold device in spontaneously ventilating volunteers.

Authors:  Douglas A Colquhoun; Kimberly Naden; Robert H Thiele
Journal:  J Clin Monit Comput       Date:  2015-06-27       Impact factor: 2.502

6.  Pulse pressure variation using a novel smartphone application (Capstesia) versus invasive pulse contour analysis in patients undergoing cardiac surgery: a secondary analysis focusing on clinical decision making.

Authors:  Olivier Desebbe; Jean-Louis Vincent; Bernd Saugel; Joseph Rinehart; Alexandre Joosten
Journal:  J Clin Monit Comput       Date:  2019-03-19       Impact factor: 2.502

7.  Monitoring of pulse pressure variation using a new smartphone application (Capstesia) versus stroke volume variation using an uncalibrated pulse wave analysis monitor: a clinical decision making study during major abdominal surgery.

Authors:  Alexandre Joosten; Alexandra Jacobs; Olivier Desebbe; Jean-Louis Vincent; Saxena Sarah; Joseph Rinehart; Luc Van Obbergh; Alexander Hapfelmeier; Bernd Saugel
Journal:  J Clin Monit Comput       Date:  2019-01-03       Impact factor: 2.502

8.  Individual differences in regional cortical volumes across the life span are associated with regional optical measures of arterial elasticity.

Authors:  Antonio M Chiarelli; Mark A Fletcher; Chin Hong Tan; Kathy A Low; Edward L Maclin; Benjamin Zimmerman; Tania Kong; Alexander Gorsuch; Gabriele Gratton; Monica Fabiani
Journal:  Neuroimage       Date:  2017-09-01       Impact factor: 6.556

9.  Accuracy of ultrasound B-lines score and E/Ea ratio to estimate extravascular lung water and its variations in patients with acute respiratory distress syndrome.

Authors:  Benoît Bataille; Guillaume Rao; Pierre Cocquet; Michel Mora; Bruno Masson; Jean Ginot; Stein Silva; Pierre-Etienne Moussot
Journal:  J Clin Monit Comput       Date:  2014-05-13       Impact factor: 2.502

Review 10.  Systematic review including re-analyses of 1148 individual data sets of central venous pressure as a predictor of fluid responsiveness.

Authors:  T G Eskesen; M Wetterslev; A Perner
Journal:  Intensive Care Med       Date:  2015-12-09       Impact factor: 17.440

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.