Literature DB >> 22083594

Local SAR in parallel transmission pulse design.

Joonsung Lee1, Matthias Gebhardt, Lawrence L Wald, Elfar Adalsteinsson.   

Abstract

The management of local and global power deposition in human subjects (specific absorption rate, SAR) is a fundamental constraint to the application of parallel transmission (pTx) systems. Even though the pTx and single channel have to meet the same SAR requirements, the complex behavior of the spatial distribution of local SAR for transmission arrays poses problems that are not encountered in conventional single-channel systems and places additional requirements on pTx radio frequency pulse design. We propose a pTx pulse design method which builds on recent work to capture the spatial distribution of local SAR in numerical tissue models in a compressed parameterization in order to incorporate local SAR constraints within computation times that accommodate pTx pulse design during an in vivo magnetic resonance imaging scan. Additionally, the algorithm yields a protocol-specific ultimate peak in local SAR, which is shown to bound the achievable peak local SAR for a given excitation profile fidelity. The performance of the approach was demonstrated using a numerical human head model and a 7 Tesla eight-channel transmit array. The method reduced peak local 10 g SAR by 14-66% for slice-selective pTx excitations and 2D selective pTx excitations compared to a pTx pulse design constrained only by global SAR. The primary tradeoff incurred for reducing peak local SAR was an increase in global SAR, up to 34% for the evaluated examples, which is favorable in cases where local SAR constraints dominate the pulse applications.
Copyright © 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 22083594      PMCID: PMC3291736          DOI: 10.1002/mrm.23140

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  23 in total

1.  Calculations of B(1) distribution, SNR, and SAR for a surface coil adjacent to an anatomically-accurate human body model.

Authors:  C M Collins; M B Smith
Journal:  Magn Reson Med       Date:  2001-04       Impact factor: 4.668

Review 2.  Sensitivity and power deposition in a high-field imaging experiment.

Authors:  D I Hoult; D Phil
Journal:  J Magn Reson Imaging       Date:  2000-07       Impact factor: 4.813

3.  Transmit SENSE.

Authors:  Ulrich Katscher; Peter Börnert; Christoph Leussler; Johan S van den Brink
Journal:  Magn Reson Med       Date:  2003-01       Impact factor: 4.668

4.  Parallel excitation with an array of transmit coils.

Authors:  Yudong Zhu
Journal:  Magn Reson Med       Date:  2004-04       Impact factor: 4.668

5.  Experimental analysis of parallel excitation using dedicated coil setups and simultaneous RF transmission on multiple channels.

Authors:  Peter Ullmann; Sven Junge; Markus Wick; Frank Seifert; Wolfgang Ruhm; Jürgen Hennig
Journal:  Magn Reson Med       Date:  2005-10       Impact factor: 4.668

6.  Spatial domain method for the design of RF pulses in multicoil parallel excitation.

Authors:  William Grissom; Chun-yu Yip; Zhenghui Zhang; V Andrew Stenger; Jeffrey A Fessler; Douglas C Noll
Journal:  Magn Reson Med       Date:  2006-09       Impact factor: 4.668

7.  Exploring the limits of RF shimming for high-field MRI of the human head.

Authors:  Weihua Mao; Michael B Smith; Christopher M Collins
Journal:  Magn Reson Med       Date:  2006-10       Impact factor: 4.668

8.  Fast-kz three-dimensional tailored radiofrequency pulse for reduced B1 inhomogeneity.

Authors:  Suwit Saekho; Chun-yu Yip; Douglas C Noll; Fernando E Boada; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2006-04       Impact factor: 4.668

9.  SAR and B1 field distributions in a heterogeneous human head model within a birdcage coil. Specific energy absorption rate.

Authors:  C M Collins; S Li; M B Smith
Journal:  Magn Reson Med       Date:  1998-12       Impact factor: 4.668

10.  Local specific absorption rate control for parallel transmission by virtual observation points.

Authors:  Gabriele Eichfelder; Matthias Gebhardt
Journal:  Magn Reson Med       Date:  2011-05-20       Impact factor: 4.668

View more
  34 in total

Review 1.  Magnetic resonance imaging at ultrahigh fields.

Authors:  Kamil Ugurbil
Journal:  IEEE Trans Biomed Eng       Date:  2014-03-25       Impact factor: 4.538

Review 2.  RF pulse methods for use with surface coils: Frequency-modulated pulses and parallel transmission.

Authors:  Michael Garwood; Kamil Uğurbil
Journal:  J Magn Reson       Date:  2018-04-26       Impact factor: 2.229

3.  SAR reduction in 7T C-spine imaging using a "dark modes" transmit array strategy.

Authors:  Yigitcan Eryaman; Bastien Guerin; Boris Keil; Azma Mareyam; Joaquin L Herraiz; Robert K Kosior; Adrian Martin; Angel Torrado-Carvajal; Norberto Malpica; Juan A Hernandez-Tamames; Emanuele Schiavi; Elfar Adalsteinsson; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2014-04-18       Impact factor: 4.668

4.  Comparison of simulated parallel transmit body arrays at 3 T using excitation uniformity, global SAR, local SAR, and power efficiency metrics.

Authors:  Bastien Guérin; Matthias Gebhardt; Peter Serano; Elfar Adalsteinsson; Michael Hamm; Josef Pfeuffer; Juergen Nistler; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2014-04-18       Impact factor: 4.668

5.  Parallel transmission pulse design with explicit control for the specific absorption rate in the presence of radiofrequency errors.

Authors:  Adrian Martin; Emanuele Schiavi; Yigitcan Eryaman; Joaquin L Herraiz; Borjan Gagoski; Elfar Adalsteinsson; Lawrence L Wald; Bastien Guerin
Journal:  Magn Reson Med       Date:  2015-07-03       Impact factor: 4.668

6.  Parallel transmission RF pulse design with strict temperature constraints.

Authors:  Cem M Deniz; Giuseppe Carluccio; Christopher Collins
Journal:  NMR Biomed       Date:  2017-02-10       Impact factor: 4.044

7.  Simultaneous multislice multiband parallel radiofrequency excitation with independent slice-specific transmit B1 homogenization.

Authors:  Xiaoping Wu; Sebastian Schmitter; Edward J Auerbach; Steen Moeller; Kâmil Uğurbil; Pierre-François Van de Moortele
Journal:  Magn Reson Med       Date:  2013-06-25       Impact factor: 4.668

8.  A generalized slab-wise framework for parallel transmit multiband RF pulse design.

Authors:  Xiaoping Wu; Sebastian Schmitter; Edward J Auerbach; Kâmil Uğurbil; Pierre-François Van de Moortele
Journal:  Magn Reson Med       Date:  2015-05-20       Impact factor: 4.668

9.  Design of parallel transmission pulses for simultaneous multislice with explicit control for peak power and local specific absorption rate.

Authors:  Bastien Guérin; Kawin Setsompop; Huihui Ye; Benedikt A Poser; Andrew V Stenger; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2014-06-17       Impact factor: 4.668

10.  Optically controlled on-coil amplifier with RF monitoring feedback.

Authors:  Natalia Gudino; Jacco A de Zwart; Qi Duan; Stephen J Dodd; Joe Murphy-Boesch; Peter van Gelderen; Jeff H Duyn
Journal:  Magn Reson Med       Date:  2017-09-14       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.