Literature DB >> 28905426

Optically controlled on-coil amplifier with RF monitoring feedback.

Natalia Gudino1, Jacco A de Zwart1, Qi Duan1, Stephen J Dodd1, Joe Murphy-Boesch1, Peter van Gelderen1, Jeff H Duyn1.   

Abstract

PURPOSE: To develop a new optically controlled on-coil amplifier that facilitates safe use of multi-channel radiofrequency (RF) transmission in MRI by real-time monitoring of signal phase and amplitude.
METHODS: Monitoring was carried out with a 4-channel prototype system by sensing, down sampling, digitizing, and optically transmitting the RF transmit signal to a remote PC to control the amplifiers. Performance was evaluated with benchtop and 7 T MRI experiments.
RESULTS: Monitored amplitude and phase were stable across repetitions and had standard deviations of 0.061 μT and 0.0073 rad, respectively. The feedback system allowed inter-channel phase and B1 amplitude to be adjusted within two iterations. MRI experiments demonstrated the feasibility of this approach to perform safe and accurate multi-channel RF transmission and monitoring at high field.
CONCLUSION: We demonstrated a 4-channel transceiver system based on optically controlled on-coil amplifiers with RF signal monitoring and feedback control. The approach allows the safe and precise control of RF transmission fields, required to achieve uniform excitation at high field. Magn Reson Med 79:2833-2841, 2018.
© 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  RF amplifiers; RF monitoring; high field MRI; parallel transmission and safety

Mesh:

Year:  2017        PMID: 28905426      PMCID: PMC5839114          DOI: 10.1002/mrm.26916

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  16 in total

1.  Signal-to-noise ratio and parallel imaging performance of a 16-channel receive-only brain coil array at 3.0 Tesla.

Authors:  Jacco A de Zwart; Patrick J Ledden; Peter van Gelderen; Jerzy Bodurka; Renxin Chu; Jeff H Duyn
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

2.  The NMR multi-transmit phased array: a Cartesian feedback approach.

Authors:  D I Hoult; G Kolansky; D Kripiakevich; S B King
Journal:  J Magn Reson       Date:  2004-11       Impact factor: 2.229

3.  Exploring the limits of RF shimming for high-field MRI of the human head.

Authors:  Weihua Mao; Michael B Smith; Christopher M Collins
Journal:  Magn Reson Med       Date:  2006-10       Impact factor: 4.668

4.  Reduction of transmitter B1 inhomogeneity with transmit SENSE slice-select pulses.

Authors:  Zhenghui Zhang; Chun-Yu Yip; William Grissom; Douglas C Noll; Fernando E Boada; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2007-05       Impact factor: 4.668

5.  A multichannel, real-time MRI RF power monitor for independent SAR determination.

Authors:  Abdel-Monem M El-Sharkawy; Di Qian; Paul A Bottomley; William A Edelstein
Journal:  Med Phys       Date:  2012-05       Impact factor: 4.071

6.  High efficiency radiofrequency power amplifier module for parallel transmit arrays at 3 Tesla.

Authors:  Michael Twieg; Mark A Griswold
Journal:  Magn Reson Med       Date:  2016-10-31       Impact factor: 4.668

7.  On-coil multiple channel transmit system based on class-D amplification and pre-amplification with current amplitude feedback.

Authors:  Natalia Gudino; Jeremiah A Heilman; Matthew J Riffe; Oliver Heid; Markus Vester; Mark A Griswold
Journal:  Magn Reson Med       Date:  2012-08-13       Impact factor: 4.668

8.  Specific absorption rate studies of the parallel transmission of inner-volume excitations at 7T.

Authors:  Adam C Zelinski; Leonardo M Angelone; Vivek K Goyal; Giorgio Bonmassar; Elfar Adalsteinsson; Lawrence L Wald
Journal:  J Magn Reson Imaging       Date:  2008-10       Impact factor: 4.813

9.  Multi-turn transmit coil to increase b1 efficiency in current source amplification.

Authors:  N Gudino; M A Griswold
Journal:  Magn Reson Med       Date:  2013-02-11       Impact factor: 4.668

10.  Slice-selective RF pulses for in vivo B1+ inhomogeneity mitigation at 7 tesla using parallel RF excitation with a 16-element coil.

Authors:  Kawin Setsompop; Vijayanand Alagappan; Borjan Gagoski; Thomas Witzel; Jonathan Polimeni; Andreas Potthast; Franz Hebrank; Ulrich Fontius; Franz Schmitt; Lawrence L Wald; Elfar Adalsteinsson
Journal:  Magn Reson Med       Date:  2008-12       Impact factor: 4.668

View more
  1 in total

1.  Eight-channel parallel transmit-receive system for 7 T MRI with optically controlled and monitored on-coil current-mode RF amplifiers.

Authors:  Natalia Gudino; Jacco A de Zwart; Jeff H Duyn
Journal:  Magn Reson Med       Date:  2020-07-14       Impact factor: 3.737

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.