Literature DB >> 11283998

Calculations of B(1) distribution, SNR, and SAR for a surface coil adjacent to an anatomically-accurate human body model.

C M Collins1, M B Smith.   

Abstract

Calculations of the radiofrequency magnetic (B(1)) field, SAR, and SNR as functions of frequency between 64 and 345 MHz for a surface coil against an anatomically-accurate human chest are presented. Calculated B(1) field distributions are in good agreement with previously-published experimental results up to 175 MHz, especially considering the dependence of field behavior on subject anatomy. Calculated SNR in the heart agrees well with theory for low frequencies (nearly linear increase with B(0) field strength). Above 175 MHz, the trend in SNR with frequency begins to depend largely on location in the heart. At all frequencies, present limits on local (1 g) SAR levels are exceeded before limits on whole-body average limits. At frequencies above 175 MHz, limits on SAR begin to be an issue in some common imaging sequences. These results are relevant for coils and subjects similar to those modeled here. Magn Reson Med 45:692-699, 2001. Copyright 2001 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2001        PMID: 11283998     DOI: 10.1002/mrm.1092

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  45 in total

1.  Parallel-plate waveguide for volume radio frequency transmission in MRI.

Authors:  Hai Lu; Shuo Shang; Shumin Wang
Journal:  Magn Reson Med       Date:  2014-11-13       Impact factor: 4.668

2.  Interventional loopless antenna at 7 T.

Authors:  Mehmet Arcan Ertürk; Abdel-Monem M El-Sharkawy; Paul A Bottomley
Journal:  Magn Reson Med       Date:  2011-12-12       Impact factor: 4.668

3.  Bias field inconsistency correction of motion-scattered multislice MRI for improved 3D image reconstruction.

Authors:  Kio Kim; Piotr A Habas; Vidya Rajagopalan; Julia A Scott; James M Corbett-Detig; Francois Rousseau; A James Barkovich; Orit A Glenn; Colin Studholme
Journal:  IEEE Trans Med Imaging       Date:  2011-04-19       Impact factor: 10.048

Review 4.  [Clinical high- and ultrahigh-field MR and its interaction with biological systems].

Authors:  A Kangarlu; K T Baudendistel; J T Heverhagen; M V Knopp
Journal:  Radiologe       Date:  2004-01       Impact factor: 0.635

5.  Surface coil with reduced specific absorption rate for rat MRI at 7 T.

Authors:  Sergio E Solis-Najera; Rodrigo Martin; Fabian Vazquez; Alfredo O Rodriguez
Journal:  MAGMA       Date:  2015-10-08       Impact factor: 2.310

6.  Rapid volumetric MRI using parallel imaging with order-of-magnitude accelerations and a 32-element RF coil array: feasibility and implications.

Authors:  Daniel K Sodickson; Christopher J Hardy; Yudong Zhu; Randy O Giaquinto; Patrick Gross; Gontran Kenwood; Thoralf Niendorf; Hubert Lejay; Charles A McKenzie; Michael A Ohliger; Aaron K Grant; Neil M Rofsky
Journal:  Acad Radiol       Date:  2005-05       Impact factor: 3.173

7.  Electromagnetic Field and Radio Frequency Circuit Co-Simulation for Magnetic Resonance Imaging Dual-Tuned Radio Frequency Coils.

Authors:  Nan Li; Shengping Liu; Xiaoqing Hu; Chao Luo; Xiaoliang Zhang; Ye Li
Journal:  IEEE Trans Magn       Date:  2017-10-16       Impact factor: 1.700

8.  An Actively Decoupled Dual Transceiver Coil System for Continuous ASL at 7 T.

Authors:  Randall B Stafford; Myung-Kyun Woo; Se-Hong Oh; Sudipto Dolui; Tiejun Zhao; Young-Bo Kim; John A Detre; Zang-Hee Cho; Jongho Lee
Journal:  Int J Imaging Syst Technol       Date:  2016-06-16       Impact factor: 2.000

Review 9.  Numerical field calculations considering the human subject for engineering and safety assurance in MRI.

Authors:  Christopher M Collins
Journal:  NMR Biomed       Date:  2009-11       Impact factor: 4.044

10.  Real-time 3D imaging of microstructure growth in battery cells using indirect MRI.

Authors:  Andrew J Ilott; Mohaddese Mohammadi; Hee Jung Chang; Clare P Grey; Alexej Jerschow
Journal:  Proc Natl Acad Sci U S A       Date:  2016-09-12       Impact factor: 11.205

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.