Literature DB >> 9840829

SAR and B1 field distributions in a heterogeneous human head model within a birdcage coil. Specific energy absorption rate.

C M Collins1, S Li, M B Smith.   

Abstract

Calculations of radiofrequency magnetic (B1) field and specific energy absorption rate (SAR) distributions in a sphere of tissue and a multi-tissue human head model in a 12-element birdcage coil are presented. The coil model is driven in linear and quadrature modes at 63, 175, 200, and 300 MHz. Plots of B1 field magnitude and SAR distributions, average SAR, maximum local SAR, and measures of B1 field homogeneity and signal-to-noise ratio are given. SAR levels for arbitrary pulse sequences can be estimated from the calculated data. Maximum local SAR levels are lower at lower frequencies, in quadrature rather than in linear coils, and in linear fields oriented posterior-to-anterior rather than left-to-right in the head. It should be possible to perform many experiments in the head at frequencies up to 300 MHz without exceeding standard limits for local or average SAR levels.

Entities:  

Mesh:

Year:  1998        PMID: 9840829     DOI: 10.1002/mrm.1910400610

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  70 in total

1.  MR imaging of RF heating using a paramagnetic doped agarose phantom.

Authors:  E M Shapiro; A Borthakur; R Reddy
Journal:  MAGMA       Date:  2000-06       Impact factor: 2.310

2.  Influence of EEG electrodes on the BOLD fMRI signal.

Authors:  G Bonmassar; N Hadjikhani; J R Ives; D Hinton; J W Belliveau
Journal:  Hum Brain Mapp       Date:  2001-10       Impact factor: 5.038

3.  Fast MRI of RF heating via phase difference mapping.

Authors:  Erik M Shapiro; Arijitt Borthakur; Michael J Shapiro; Ravinder Reddy; John S Leigh
Journal:  Magn Reson Med       Date:  2002-03       Impact factor: 4.668

4.  Liver T1ρ MRI measurement in healthy human subjects at 3 T: a preliminary study with a two-dimensional fast-field echo sequence.

Authors:  M Deng; F Zhao; J Yuan; A T Ahuja; Y-X J Wang
Journal:  Br J Radiol       Date:  2012-03-14       Impact factor: 3.039

5.  Comparison of Four Different Shields for Birdcage-Type Coils with Experiments and Numerical Calculations.

Authors:  Wanzhan Liu; Shutong Zhang; Christopher M Collins; Jianli Wang; Michael B Smith
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2006-10-09       Impact factor: 1.176

6.  Compensation for spin-lock artifacts using an off-resonance rotary echo in T1rhooff-weighted imaging.

Authors:  Walter R T Witschey; Arijitt Borthakur; Mark A Elliott; Eric Mellon; Sampreet Niyogi; Chenyang Wang; Ravinder Reddy
Journal:  Magn Reson Med       Date:  2007-01       Impact factor: 4.668

7.  An RF dosimeter for independent SAR measurement in MRI scanners.

Authors:  Di Qian; Abdel-Monem M El-Sharkawy; Paul A Bottomley; William A Edelstein
Journal:  Med Phys       Date:  2013-12       Impact factor: 4.071

8.  Short-term side-effects of brain MR examination at 7 T: a single-centre experience.

Authors:  M Cosottini; D Frosini; L Biagi; I Pesaresi; M Costagli; G Tiberi; M Symms; M Tosetti
Journal:  Eur Radiol       Date:  2014-05-10       Impact factor: 5.315

Review 9.  Sodium and T1rho MRI for molecular and diagnostic imaging of articular cartilage.

Authors:  Arijitt Borthakur; Eric Mellon; Sampreet Niyogi; Walter Witschey; J Bruce Kneeland; Ravinder Reddy
Journal:  NMR Biomed       Date:  2006-11       Impact factor: 4.044

10.  Measurements of RF heating during 3.0-T MRI of a pig implanted with deep brain stimulator.

Authors:  Krzysztof R Gorny; Michael F Presti; Stephan J Goerss; Sun C Hwang; Dong-Pyo Jang; Inyong Kim; Hoon-Ki Min; Yunhong Shu; Christopher P Favazza; Kendall H Lee; Matt A Bernstein
Journal:  Magn Reson Imaging       Date:  2012-12-07       Impact factor: 2.546

View more