Literature DB >> 22068373

Residual limb volume change: systematic review of measurement and management.

Joan E Sanders1, Stefania Fatone.   

Abstract

Management of residual limb volume affects decisions regarding timing of fit of the first prosthesis, when a new prosthetic socket is needed, design of a prosthetic socket, and prescription of accommodation strategies for daily volume fluctuations. This systematic review assesses what is known about measurement and management of residual limb volume change in persons with lower-limb amputation. Publications that met inclusion criteria were grouped into three categories: group I: descriptions of residual limb volume measurement techniques; group II: studies investigating the effect of residual limb volume change on clinical care in people with lower-limb amputation; and group III: studies of residual limb volume management techniques or descriptions of techniques for accommodating or controlling residual limb volume. We found that many techniques for the measurement of residual limb volume have been described but clinical use is limited largely because current techniques lack adequate resolution and in-socket measurement capability. Overall, limited evidence exists regarding the management of residual limb volume, and the evidence available focuses primarily on adults with transtibial amputation in the early postoperative phase. While we can draw some insights from the available research about residual limb volume measurement and management, further research is required.

Entities:  

Mesh:

Year:  2011        PMID: 22068373      PMCID: PMC4423813          DOI: 10.1682/jrrd.2010.09.0189

Source DB:  PubMed          Journal:  J Rehabil Res Dev        ISSN: 0748-7711


  61 in total

1.  Shape and volume change in the transtibial residuum over the short term: preliminary investigation of six subjects.

Authors:  Santosh G Zachariah; Rakesh Saxena; John R Fergason; Joan E Sanders
Journal:  J Rehabil Res Dev       Date:  2004-09

2.  Comparison of the results of four users of a contemporary CAD/CAM system.

Authors:  T McGarry; B McHugh
Journal:  Prosthet Orthot Int       Date:  2007-03       Impact factor: 1.895

3.  Interface pressures during ambulation using suction and vacuum-assisted prosthetic sockets.

Authors:  Tracy L Beil; Glenn M Street; Steven J Covey
Journal:  J Rehabil Res Dev       Date:  2002 Nov-Dec

4.  A PC-based ultrasonic data acquisition system for computer-aided prosthetic socket design.

Authors:  P He; K Xue; Q Chen; P Murka; S Schall
Journal:  IEEE Trans Rehabil Eng       Date:  1996-06

5.  Below-knee residual limb shape change measurement and visualization.

Authors:  P K Commean; B S Brunsden; K E Smith; M W Vannier
Journal:  Arch Phys Med Rehabil       Date:  1998-07       Impact factor: 3.966

6.  Volume changes in below-knee amputation stumps as affected by type of whirpool-tank hydrotherapy.

Authors:  M J Goldberg; J V Culver; J F Carson
Journal:  J Am Geriatr Soc       Date:  1968-01       Impact factor: 5.562

7.  Volumetric determinations with CAD/CAM in prosthetics and orthotics: errors of measurement.

Authors:  M Lilja; T Oberg
Journal:  J Rehabil Res Dev       Date:  1995-05

8.  A computerized device for the volumetric analysis of the residual limbs of amputees.

Authors:  T W Starr
Journal:  Bull Prosthet Res       Date:  1980

9.  Validation of spiral CT and optical surface scanning for lower limb stump volumetry.

Authors:  K E Smith; P K Commean; G Bhatia; M W Vannier
Journal:  Prosthet Orthot Int       Date:  1995-08       Impact factor: 1.895

10.  The effect of semirigid dressings on below-knee amputations.

Authors:  N MacLean; G H Fick
Journal:  Phys Ther       Date:  1994-07
View more
  33 in total

1.  How does adding and removing liquid from socket bladders affect residual-limb fluid volume?

Authors:  Joan E Sanders; John C Cagle; Daniel S Harrison; Timothy R Myers; Kathryn J Allyn
Journal:  J Rehabil Res Dev       Date:  2013

2.  Classifying prosthetic use via accelerometry in persons with transtibial amputations.

Authors:  Morgan T Redfield; John C Cagle; Brian J Hafner; Joan E Sanders
Journal:  J Rehabil Res Dev       Date:  2013

3.  Development of Standardized Material Testing Protocols for Prosthetic Liners.

Authors:  John C Cagle; Per G Reinhall; Brian J Hafner; Joan E Sanders
Journal:  J Biomech Eng       Date:  2017-04-01       Impact factor: 2.097

4.  A Framework for Measuring the Time-Varying Shape and Full-Field Deformation of Residual Limbs Using 3-D Digital Image Correlation.

Authors:  Dana Solav; Kevin M Moerman; Aaron M Jaeger; Hugh M Herr
Journal:  IEEE Trans Biomed Eng       Date:  2019-01-24       Impact factor: 4.538

5.  COMPARATIVE EFFECTIVENESS OF AN ADJUSTABLE TRANSFEMORAL PROSTHETIC INTERFACE ACCOMMODATING VOLUME FLUCTUATION: CASE STUDY.

Authors:  Jason T Kahle; Tyler D Klenow; M Jason Highsmith
Journal:  Technol Innov       Date:  2016-09

6.  A finite element model to assess transtibial prosthetic sockets with elastomeric liners.

Authors:  John C Cagle; Per G Reinhall; Kate J Allyn; Jake McLean; Paul Hinrichs; Brian J Hafner; Joan E Sanders
Journal:  Med Biol Eng Comput       Date:  2017-12-13       Impact factor: 2.602

7.  Retracting Locking-Pin Mechanism That Allows Partial Prosthetic Socket Doffing during Sitting.

Authors:  Mark D Goldstein; John C Cagle; Brian J Hafner; Katheryn J Allyn; Joan E Sanders
Journal:  J Prosthet Orthot       Date:  2018-04

8.  A Bioimpedance Analysis Platform for Amputee Residual Limb Assessment.

Authors:  Joan E Sanders; Mark A Moehring; Travis M Rothlisberger; Reid H Phillips; Tyler Hartley; Colin R Dietrich; Christian B Redd; David W Gardner; John C Cagle
Journal:  IEEE Trans Biomed Eng       Date:  2015-11-19       Impact factor: 4.538

9.  Device to monitor sock use in people using prosthetic limbs: technical report.

Authors:  Joan E Sanders; Revathi Murthy; John C Cagle; Katheryn J Allyn; Reid H Phillips; Brian P Otis
Journal:  J Rehabil Res Dev       Date:  2012

10.  Self-reported prosthetic sock use among persons with transtibial amputation.

Authors:  Krittika D'Silva; Brian J Hafner; Katheryn J Allyn; Joan E Sanders
Journal:  Prosthet Orthot Int       Date:  2013-08-28       Impact factor: 1.895

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.