Literature DB >> 28233885

Development of Standardized Material Testing Protocols for Prosthetic Liners.

John C Cagle1, Per G Reinhall2, Brian J Hafner3, Joan E Sanders4.   

Abstract

A set of protocols was created to characterize prosthetic liners across six clinically relevant material properties. Properties included compressive elasticity, shear elasticity, tensile elasticity, volumetric elasticity, coefficient of friction (CoF), and thermal conductivity. Eighteen prosthetic liners representing the diverse range of commercial products were evaluated to create test procedures that maximized repeatability, minimized error, and provided clinically meaningful results. Shear and tensile elasticity test designs were augmented with finite element analysis (FEA) to optimize specimen geometries. Results showed that because of the wide range of available liner products, the compressive elasticity and tensile elasticity tests required two test maxima; samples were tested until they met either a strain-based or a stress-based maximum, whichever was reached first. The shear and tensile elasticity tests required that no cyclic conditioning be conducted because of limited endurance of the mounting adhesive with some liner materials. The coefficient of friction test was based on dynamic coefficient of friction, as it proved to be a more reliable measurement than static coefficient of friction. The volumetric elasticity test required that air be released beneath samples in the test chamber before testing. The thermal conductivity test best reflected the clinical environment when thermal grease was omitted and when liner samples were placed under pressure consistent with load bearing conditions. The developed procedures provide a standardized approach for evaluating liner products in the prosthetics industry. Test results can be used to improve clinical selection of liners for individual patients and guide development of new liner products.

Entities:  

Mesh:

Year:  2017        PMID: 28233885      PMCID: PMC5444209          DOI: 10.1115/1.4035917

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  33 in total

1.  In vivo friction properties of human skin.

Authors:  M Zhang; A F Mak
Journal:  Prosthet Orthot Int       Date:  1999-08       Impact factor: 1.895

Review 2.  Patient safety in the rehabilitation of the adult with an amputation.

Authors:  Gail Latlief; Christine Elnitsky; Stephanie Hart-Hughes; Samuel L Phillips; Laurel Adams-Koss; Robert Kent; M Jason Highsmith
Journal:  Phys Med Rehabil Clin N Am       Date:  2012-05       Impact factor: 1.784

3.  Material properties of commonly-used interface materials and their static coefficients of friction with skin and socks.

Authors:  J E Sanders; J M Greve; S B Mitchell; S G Zachariah
Journal:  J Rehabil Res Dev       Date:  1998-06

4.  Clinical investigation of the interface pressure in the trans-tibial socket with Dermo and Seal-In X5 liner during walking and their effect on patient satisfaction.

Authors:  Sadeeq Ali; Noor Azuan Abu Osman; Niyousha Mortaza; Arezoo Eshraghi; Hossein Gholizadeh; Wan Abu Bakar Bin Wan Abas
Journal:  Clin Biomech (Bristol, Avon)       Date:  2012-07-12       Impact factor: 2.063

5.  Amputee skin condition: occlusion, stratum corneum hydration and free amino acid levels.

Authors:  Marty O Visscher; Marisa Robinson; Benetta Fugit; Richard J Rosenberg; Steven B Hoath; R Randall Wickett
Journal:  Arch Dermatol Res       Date:  2010-12-16       Impact factor: 3.017

6.  Changes in interface pressure and stump shape over time: preliminary results from a trans-tibial amputee subject.

Authors:  J E Sanders; J M Greve; C Clinton; B J Hafner
Journal:  Prosthet Orthot Int       Date:  2000-08       Impact factor: 1.895

7.  Effects of sitting postures on risks for deep tissue injury in the residuum of a transtibial prosthetic-user: a biomechanical case study.

Authors:  S Portnoy; I Siev-Ner; N Shabshin; A Gefen
Journal:  Comput Methods Biomech Biomed Engin       Date:  2011-06-24       Impact factor: 1.763

8.  Elastomeric liners for people with transtibial amputation: Survey of prosthetists' clinical practices.

Authors:  Brian J Hafner; John C Cagle; Katheryn J Allyn; Joan E Sanders
Journal:  Prosthet Orthot Int       Date:  2016-09-24       Impact factor: 1.895

9.  Use and satisfaction with prosthetic limb devices and related services.

Authors:  Liliana E Pezzin; Timothy R Dillingham; Ellen J Mackenzie; Patti Ephraim; Paddy Rossbach
Journal:  Arch Phys Med Rehabil       Date:  2004-05       Impact factor: 3.966

10.  Determinants of skin problems of the stump in lower-limb amputees.

Authors:  Henk E Meulenbelt; Jan H Geertzen; Marcel F Jonkman; Pieter U Dijkstra
Journal:  Arch Phys Med Rehabil       Date:  2009-01       Impact factor: 3.966

View more
  5 in total

1.  A finite element model to assess transtibial prosthetic sockets with elastomeric liners.

Authors:  John C Cagle; Per G Reinhall; Kate J Allyn; Jake McLean; Paul Hinrichs; Brian J Hafner; Joan E Sanders
Journal:  Med Biol Eng Comput       Date:  2017-12-13       Impact factor: 2.602

2.  Synthesis and characterization of a silver nanoparticle-containing polymer composite with antimicrobial abilities for application in prosthetic and orthotic devices.

Authors:  Catalina Quintero-Quiroz; Luz E Botero; Diana Zárate-Triviño; Natalia Acevedo-Yepes; Jorge Saldarriaga Escobar; Vera Z Pérez; Luis Javier Cruz Riano
Journal:  Biomater Res       Date:  2020-08-12

3.  Modeling the mechanics of elevated vacuum systems in prosthetic sockets.

Authors:  Robert T Youngblood; Brian J Hafner; Joseph M Czerniecki; Jacob T Brzostowski; Katheryn J Allyn; Joan E Sanders
Journal:  Med Eng Phys       Date:  2020-07-28       Impact factor: 2.242

4.  Using mechanical testing to assess texturing of prosthetic sockets to improve suspension in the transverse plane and reduce rotation.

Authors:  Julia Quinlan; Vasanth Subramanian; Jessica Yohay; Brad Poziembo; Stefania Fatone
Journal:  PLoS One       Date:  2020-06-11       Impact factor: 3.240

5.  Development of a magnetic composite material for measurement of residual limb displacements in prosthetic sockets.

Authors:  Ethan J Weathersby; John C Cagle; Brian G Larsen; Katrina M Henrikson; Joan E Sanders
Journal:  J Rehabil Assist Technol Eng       Date:  2018-04-03
  5 in total