Literature DB >> 7562654

Volumetric determinations with CAD/CAM in prosthetics and orthotics: errors of measurement.

M Lilja1, T Oberg.   

Abstract

During the next decade CAD/CAM technique will probably become routine in prosthetics and orthotics, not only as a complement to manual techniques, but also introducing new possibilities. However, even complex and sophisticated techniques have errors of measurement that must be considered. Such errors are of two principal kinds: systematic errors and random errors. In this study we have evaluated the Swedish CAPOD system with respect to volumetric determinations. We used two types of reference objects for volume determinations: cylinders and amputation residual limb models. Three different sizes were examined of each type of object. Volume measurements with CAPOD were compared with volumes obtained by water immersion or mathematical calculation (cylinders only). We found a constant, linear systematic error of +2.5%. Such an error can easily be corrected for. The random error, represented by the coefficient of variation, was 0.5%, which means that there is a theoretical possibility to detect volume changes exceeding 1%. We consider the precision sufficient for clinical practice in prosthetics and orthotics. Biological variations due to soft tissue deformation must be added on top of these errors. Such deformations were not evaluated in this study.

Entities:  

Mesh:

Year:  1995        PMID: 7562654

Source DB:  PubMed          Journal:  J Rehabil Res Dev        ISSN: 0748-7711


  5 in total

Review 1.  Residual limb volume change: systematic review of measurement and management.

Authors:  Joan E Sanders; Stefania Fatone
Journal:  J Rehabil Res Dev       Date:  2011

2.  A new, effective and low-cost three-dimensional approach for the estimation of upper-limb volume.

Authors:  Roberto Buffa; Elena Mereu; Paolo Lussu; Valeria Succa; Tonino Pisanu; Franco Buffa; Elisabetta Marini
Journal:  Sensors (Basel)       Date:  2015-05-26       Impact factor: 3.576

3.  Method to evaluate the noise of 3D intra-oral scanner.

Authors:  Alban Desoutter; Osama Yusuf Solieman; Gérard Subsol; Hervé Tassery; Frédéric Cuisinier; Michel Fages
Journal:  PLoS One       Date:  2017-08-09       Impact factor: 3.240

4.  Residual limb volume fluctuations in transfemoral amputees.

Authors:  Linda Paternò; Michele Ibrahimi; Elisa Rosini; Giuseppe Menfi; Vito Monaco; Emanuele Gruppioni; Leonardo Ricotti; Arianna Menciassi
Journal:  Sci Rep       Date:  2021-06-10       Impact factor: 4.379

5.  Validity and reliability of a novel 3D scanner for assessment of the shape and volume of amputees' residual limb models.

Authors:  Elena Seminati; David Canepa Talamas; Matthew Young; Martin Twiste; Vimal Dhokia; James L J Bilzon
Journal:  PLoS One       Date:  2017-09-08       Impact factor: 3.240

  5 in total