Interface pressures during ambulation using suction and vacuum-assisted prosthetic sockets.

Tracy L Beil1, Glenn M Street, Steven J Covey.   

Abstract

Interface pressures were measured during ambulation with a normal total-surface weight-bearing suction socket and a vacuum-assisted socket. The vacuum-assisted socket has been shown to eliminate daily volume loss. Urethane liners were instrumented with five force-sensing resistors to measure positive pressures and one air pressure sensor at the distal end of the liner to document negative pressures. Nine unilateral transtibial amputees participated in the study. The vacuum-assisted socket created significantly lower positive-pressure impulse (42.8, 39.6 kPa x s) and peak pressures (83.5, 80.0 kPa) during the stance phase. The pressure impulse (-10.5, -13.3 kPa x s), average (-21.2, -26.5 kPa), and peak (-28.5, -36.3 kPa) negative pressures during swing phase were significantly greater in magnitude with the vacuum-assisted socket. We believe that lower positive pressures seen during stance using the vacuum-assisted socket reduces the fluid forced out and greater negative pressures seen during swing increases the amount of fluid drawn into the limb, thereby preventing volume loss.

Entities:  

Mesh:

Year:  2002        PMID: 17943671

Source DB:  PubMed          Journal:  J Rehabil Res Dev        ISSN: 0748-7711


  20 in total

Review 1.  Residual limb volume change: systematic review of measurement and management.

Authors:  Joan E Sanders; Stefania Fatone
Journal:  J Rehabil Res Dev       Date:  2011

2.  Evaluation of Force Sensing Resistors for the Measurement of Interface Pressures in Lower Limb Prosthetics.

Authors:  Eric Swanson; Ethan Weathersby; John Cagle; Joan E Sanders
Journal:  J Biomech Eng       Date:  2019-04-24       Impact factor: 2.097

3.  Evaluation of a Prototype Hybrid Vacuum Pump to Provide Vacuum-Assisted Suspension for Above-Knee Prostheses.

Authors:  Matthew J Major; Ryan Caldwell; Stefania Fatone
Journal:  J Med Device       Date:  2015-08-06       Impact factor: 0.582

4.  Effect of prosthetic alignment changes on socket reaction moment impulse during walking in transtibial amputees.

Authors:  Toshiki Kobayashi; Michael S Orendurff; Adam K Arabian; Teri G Rosenbaum-Chou; David A Boone
Journal:  J Biomech       Date:  2014-02-14       Impact factor: 2.712

5.  Evaluation of pelvis postural systems in spinal cord injury patients: Outcome research.

Authors:  Serena Dattoli; Mariele Colucci; Maria Grazia Soave; Rita De Santis; Leandro Segaletti; Claudia Corsi; Marco Tofani; Donatella Valente; Giovanni Galeoto
Journal:  J Spinal Cord Med       Date:  2018-04-18       Impact factor: 1.985

6.  Vacuum level effects on gait characteristics for unilateral transtibial amputees with elevated vacuum suspension.

Authors:  Hang Xu; Kasey Greenland; Donald Bloswick; Jie Zhao; Andrew Merryweather
Journal:  Clin Biomech (Bristol, Avon)       Date:  2017-02-14       Impact factor: 2.063

7.  Deleterious Musculoskeletal Conditions Secondary to Lower Limb Loss: Considerations for Prosthesis-Related Factors.

Authors:  Ashley D Knight; Christopher L Dearth; Brad D Hendershot
Journal:  Adv Wound Care (New Rochelle)       Date:  2020-05-22       Impact factor: 4.730

8.  Textile-based Pressure Sensors for Monitoring Prosthetic-Socket Interfaces.

Authors:  Jordan Tabor; Talha Agcayazi; Aaron Fleming; Brendan Thompson; Ashish Kapoor; Ming Liu; Michael Lee; He Helen Huang; Alper Bozkurt; Tushar Ghosh
Journal:  IEEE Sens J       Date:  2021-01-21       Impact factor: 3.301

9.  Effectiveness of elevated vacuum and suction prosthetic suspension systems in managing daily residual limb fluid volume change in people with transtibial amputation.

Authors:  Robert T Youngblood; Jacob T Brzostowski; Brian J Hafner; Joseph M Czerniecki; Katheryn J Allyn; Richard L Foster; Joan E Sanders
Journal:  Prosthet Orthot Int       Date:  2020-03-18       Impact factor: 1.895

10.  Residual limb volume fluctuations in transfemoral amputees.

Authors:  Linda Paternò; Michele Ibrahimi; Elisa Rosini; Giuseppe Menfi; Vito Monaco; Emanuele Gruppioni; Leonardo Ricotti; Arianna Menciassi
Journal:  Sci Rep       Date:  2021-06-10       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.