COMPARATIVE EFFECTIVENESS OF AN ADJUSTABLE TRANSFEMORAL PROSTHETIC INTERFACE ACCOMMODATING VOLUME FLUCTUATION: CASE STUDY.

Jason T Kahle1, Tyler D Klenow2, M Jason Highsmith3.   

Abstract

The socket-limb interface is vital for functionality and provides stability and mobility for the amputee. Volume fluctuation can lead to compromised fit and function. Current socket technology does not accommodate for volume fluctuation. An adjustable interface may improve function and comfort by filling this technology gap. The purpose of this study was to compare the effectiveness of the standard of care (SOC) ischial ramus containment to an adjustable transfemoral prosthetic interface socket in the accommodation of volume fluctuation. A prospective experimental case study using repeated measures of subjective and performance outcome measures between socket conditions was employed. In the baseline volume condition, the adjustable socket improved subjective and performance measures 19% to 37% over SOC, whereas the two-minute walk test demonstrated equivalence. In the volume loss condition, the adjustable socket improved all subjective and performance measures 22% to 93%. All aggregated data improved 16% to 50% compared with the SOC. In simulated volume gain, the SOC socket failed, while the subject was able to complete the protocol using the adjustable socket. In this case study, the SOC socket was inferior to the comparative adjustable transfemoral amputation interface in subjective and performance outcomes. There is a lack of clinical trials and evidence comparing socket functional outcomes related to volume fluctuation.

Entities:  

Keywords:  Amputee; Ischial containment; Limb loss; Lower extremity amputee; Rehabilitation; Socket

Year:  2016        PMID: 28066526      PMCID: PMC5218538          DOI: 10.21300/18.2-3.2016.175

Source DB:  PubMed          Journal:  Technol Innov


  30 in total

1.  Assessment technique for computer-aided manufactured sockets.

Authors:  Joan E Sanders; Michael R Severance
Journal:  J Rehabil Res Dev       Date:  2011

2.  Development of a clinical measure of turning for older adults.

Authors:  Wayne Dite; Viviene A Temple
Journal:  Am J Phys Med Rehabil       Date:  2002-11       Impact factor: 2.159

3.  Unilateral lower-limb loss: prosthetic device use and functional outcomes in servicemembers from Vietnam war and OIF/OEF conflicts.

Authors:  Robert Gailey; Lynne V McFarland; Rory A Cooper; Joseph Czerniecki; Jeffrey M Gambel; Sharon Hubbard; Charles Maynard; Douglas G Smith; Michele Raya; Gayle E Reiber
Journal:  J Rehabil Res Dev       Date:  2010

4.  Falls sustained during inpatient rehabilitation after lower limb amputation: prevalence and predictors.

Authors:  Tim Pauley; Michael Devlin; Kathleen Heslin
Journal:  Am J Phys Med Rehabil       Date:  2006-06       Impact factor: 2.159

5.  Assessment of residual-limb volume change using bioimpedence.

Authors:  Joan E Sanders; Ellen L Rogers; Daniel C Abrahamson
Journal:  J Rehabil Res Dev       Date:  2007

6.  Prosthetic usage following major lower extremity amputation.

Authors:  T J Moore; J Barron; F Hutchinson; C Golden; C Ellis; D Humphries
Journal:  Clin Orthop Relat Res       Date:  1989-01       Impact factor: 4.176

7.  Volume fluctuations in the residual limbs of lower limb amputees.

Authors:  G R Fernie; P J Holliday
Journal:  Arch Phys Med Rehabil       Date:  1982-04       Impact factor: 3.966

8.  Effects of fall injury type and discharge placement on mortality, hospitalization, falls, and ADL changes among older people in Taiwan.

Authors:  Wen-Yu Yu; Hei-Fen Hwang; Ming-Hsia Hu; Chih-Yi Chen; Mau-Roung Lin
Journal:  Accid Anal Prev       Date:  2012-08-09

Review 9.  Exercise in preventing falls and fall related injuries in older people: a review of randomised controlled trials.

Authors:  M M Gardner; M C Robertson; A J Campbell
Journal:  Br J Sports Med       Date:  2000-02       Impact factor: 13.800

10.  Postural responses to dynamic perturbations in amputee fallers versus nonfallers: a comparative study with able-bodied subjects.

Authors:  Natalie Vanicek; Siobhan Strike; Lars McNaughton; Remco Polman
Journal:  Arch Phys Med Rehabil       Date:  2009-06       Impact factor: 3.966

View more
  5 in total

1.  Design for Transtibial Modifiable Socket for Immediate Postoperative Prosthesis.

Authors:  Matthew N Rush; Evan Hagin; Jane Nguyen; Victoria Lujan; Rebecca A Dutton; Christina Salas
Journal:  Univ N M Orthop Res J       Date:  2019

Review 2.  Limb Prostheses: Industry 1.0 to 4.0: Perspectives on Technological Advances in Prosthetic Care.

Authors:  Silvia Ursula Raschke
Journal:  Front Rehabil Sci       Date:  2022-03-10

3.  Analysis of lower limb prosthetic socket interface based on stress and motion measurements.

Authors:  Jinghua Tang; Liudi Jiang; Michael McGrath; Dan Bader; Piotr Laszczak; David Moser; Saeed Zahedi
Journal:  Proc Inst Mech Eng H       Date:  2022-07-12       Impact factor: 1.763

4.  Residual limb volume fluctuations in transfemoral amputees.

Authors:  Linda Paternò; Michele Ibrahimi; Elisa Rosini; Giuseppe Menfi; Vito Monaco; Emanuele Gruppioni; Leonardo Ricotti; Arianna Menciassi
Journal:  Sci Rep       Date:  2021-06-10       Impact factor: 4.379

5.  Thin Magnetically Permeable Targets for Inductive Sensing: Application to Limb Prosthetics.

Authors:  Ethan J Weathersby; Clement J Gurrey; Jake B McLean; Benjamin N Sanders; Brian G Larsen; Ryan Carter; Joseph L Garbini; Joan E Sanders
Journal:  Sensors (Basel)       Date:  2019-09-19       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.