Below-knee residual limb shape change measurement and visualization.

P K Commean1, B S Brunsden, K E Smith, M W Vannier.   

Abstract

OBJECTIVE: The ability to measure and visualize shape change (deformation) of a residual limb within and between prostheses is an important step toward improved prosthetic fit assessment. The objective was to develop measurement and visualization methods for below-knee residual limb soft tissue shape change after donning and loading a prosthesis to detect small shape changes (30mm or less).
DESIGN: Spiral X-ray computed tomography imaging was utilized to acquire 3D volumetric data of the below-knee residual limb and prosthesis in situ from poor- and a good-fitting prostheses without and with a load. A new sum projection depth-shaded cylindrical mapping technique to measure and visualize small changes in shape was developed. From the volumetric data, the relative displacement of small lead markers placed on the residual limb's skin surface were measured using multiplanar reconstruction images and cylindrical maps. Displacement measurements averaging 15mm or less were obtained.
RESULTS: The precision and accuracy was 1mm and 2mm, respectively, when measuring the shape change or deformation of the skin surface from the sum projection cylindrical maps. The skin surface deformation was at least 7mm or greater when comparing marker locations between scans with the prostheses in situ.
CONCLUSION: These new image-based measurement and visualization methods provide a feasible means for measuring and displaying lower extremity residual limb shape change within and between different prostheses with and without loading.

Mesh:

Year:  1998        PMID: 9685090     DOI: 10.1016/s0003-9993(98)90355-0

Source DB:  PubMed          Journal:  Arch Phys Med Rehabil        ISSN: 0003-9993            Impact factor:   3.966


  3 in total

Review 1.  Residual limb volume change: systematic review of measurement and management.

Authors:  Joan E Sanders; Stefania Fatone
Journal:  J Rehabil Res Dev       Date:  2011

2.  A means to accommodate residual limb movement during optical scanning: a technical note.

Authors:  Joan E Sanders; Gregory S Lee
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2008-10       Impact factor: 3.802

3.  Validity and reliability of a novel 3D scanner for assessment of the shape and volume of amputees' residual limb models.

Authors:  Elena Seminati; David Canepa Talamas; Matthew Young; Martin Twiste; Vimal Dhokia; James L J Bilzon
Journal:  PLoS One       Date:  2017-09-08       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.