Literature DB >> 22048865

Proximal component modularity in THA--at what cost? An implant retrieval study.

A M Kop1, C Keogh, E Swarts.   

Abstract

BACKGROUND: While modular femoral heads have been used in THA for decades, a recent innovation is a second neck-stem taper junction. Clinical advantages include intraoperative adjustment of leg length, femoral anteversion, and easier revision, all providing flexibility to the surgeon; however, there have been reports of catastrophic fracture, cold welding, and corrosion and fretting of the modular junction. QUESTIONS/PURPOSES: We asked whether (1) the neck-stem junction showed the same degradation mechanisms, if any, as the head-neck junction, (2) the junction contributed to THA revision, (3) the alloy affected the degree of degradation, and (4) the trunion machine finish affected the degradation mechanisms.
METHODS: We compared 57 retrievals from seven total hip modular designs, three cobalt-chromium-molybdenum and four titanium based: Bionik(®) (four), GMRS(®) (four), Margron(®) (22), Apex(®) (five), M-series(®) (five), ZMR(®) (two), and S-ROM(®) (15). Macroscopic inspection, microscopy, and micro-CT were conducted to determine the effects of materials and design.
RESULTS: The cobalt-chromium-molybdenum components showed crevice corrosion and fretting of the neck-stem taper, whereas the titanium components had less corrosion; however, there were several cases of cold welding where disassembly could not be achieved in theater.
CONCLUSIONS: Even with modern taper designs and corrosion-resistant materials, corrosion, fretting, and particulate debris were observed to a greater extent in the second neck-stem junction. Titanium-based modular arthroplasty may lessen the degree of degradation, but cold welding of the components may occur. CLINICAL RELEVANCE: Degradation of the second junction contributed to 8 cases of metallosis and two cases of aseptic lymphocyte-laminated vascular-associated lesions contributing to revision.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22048865      PMCID: PMC3369081          DOI: 10.1007/s11999-011-2155-9

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  22 in total

1.  The Morse taper junction in modular revision hip replacement--a biomechanical and retrieval analysis.

Authors:  M Schramm; D C Wirtz; U Holzwarth; R P Pitto
Journal:  Biomed Tech (Berl)       Date:  2000-04       Impact factor: 1.411

2.  Design-related fretting wear in modular neck hip prosthesis.

Authors:  M Viceconti; O Ruggeri; A Toni; A Giunti
Journal:  J Biomed Mater Res       Date:  1996-02

3.  In-vitro corrosion and wear of titanium alloys in the biological environment.

Authors:  M A Khan; R L Williams; D F Williams
Journal:  Biomaterials       Date:  1996-11       Impact factor: 12.479

4.  Complications of femoral and acetabular modularity.

Authors:  E A Salvati; J R Lieberman; O L Huk; B G Evans
Journal:  Clin Orthop Relat Res       Date:  1995-10       Impact factor: 4.176

5.  The tradeoffs associated with modular hip prostheses.

Authors:  J P Collier; M B Mayor; I R Williams; V A Surprenant; H P Surprenant; B H Currier
Journal:  Clin Orthop Relat Res       Date:  1995-02       Impact factor: 4.176

6.  Corrosion and wear at the modular interface of uncemented femoral stems.

Authors:  S D Cook; R L Barrack; A J Clemow
Journal:  J Bone Joint Surg Br       Date:  1994-01

7.  Fretting corrosion studies of universal femoral head prostheses and cone taper spigots.

Authors:  D C Fricker; R Shivanath
Journal:  Biomaterials       Date:  1990-09       Impact factor: 12.479

8.  The proximal modular neck in THA: a bridge too far: opposes.

Authors:  Hugh U Cameron
Journal:  Orthopedics       Date:  2010-09-07       Impact factor: 1.390

9.  Local and distant products from modularity.

Authors:  J J Jacobs; R M Urban; J L Gilbert; A K Skipor; J Black; M Jasty; J O Galante
Journal:  Clin Orthop Relat Res       Date:  1995-10       Impact factor: 4.176

10.  The cumulative long-term risk of dislocation after primary Charnley total hip arthroplasty.

Authors:  Daniel J Berry; Marius von Knoch; Cathy D Schleck; W Scott Harmsen
Journal:  J Bone Joint Surg Am       Date:  2004-01       Impact factor: 5.284

View more
  28 in total

1.  Metallosis following a dual coat porous hydroxyapatite shoulder hemiarthroplasty.

Authors:  Humza Khan; Mark Hurworth; Alan Kop
Journal:  J Orthop       Date:  2015-03-12

2.  Stem-Sleeve Junction Failure of a Modular Femoral Hip System: a Retrieval Analysis.

Authors:  Feras Waly; Fahad H Abduljabbar; Trevor Gascoyne; Thomas R Turgeon; Olga Huk
Journal:  HSS J       Date:  2015-07-09

Review 3.  The biological response to orthopaedic implants for joint replacement: Part I: Metals.

Authors:  Emmanuel Gibon; Derek F Amanatullah; Florence Loi; Jukka Pajarinen; Akira Nabeshima; Zhenyu Yao; Moussa Hamadouche; Stuart B Goodman
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2016-06-21       Impact factor: 3.368

Review 4.  Management bone loss of the proximal femur in revision hip arthroplasty: Update on reconstructive options.

Authors:  Vasileios I Sakellariou; George C Babis
Journal:  World J Orthop       Date:  2014-11-18

5.  Result of Modular Necks in Primary Total Hip Arthroplasty with a Average Follow-up of Four Years.

Authors:  Jemin Yi; Kye Young Han; Young Jun Nam; Keun Woo Kim
Journal:  Hip Pelvis       Date:  2016-09-30

6.  Are titanium-on-titanium TiAl6V4 modular necks safe in total hip arthroplasty for non-overweight patients? Results of a prospective series at a minimum follow-up of 7 years.

Authors:  Matthieu Ollivier; Sébastien Parratte; Alexandre Galland; Alexandre Lunebourg; Jean-Noel Argenson
Journal:  Eur J Orthop Surg Traumatol       Date:  2015-07-10

7.  Adverse local tissue reaction arising from corrosion at the femoral neck-body junction in a dual-taper stem with a cobalt-chromium modular neck.

Authors:  H John Cooper; Robert M Urban; Richard L Wixson; R Michael Meneghini; Joshua J Jacobs
Journal:  J Bone Joint Surg Am       Date:  2013-05-15       Impact factor: 5.284

8.  Trunnionosis: the latest culprit in adverse reactions to metal debris following hip arthroplasty.

Authors:  Ryan M Shulman; Michael G Zywiel; Rajiv Gandhi; J Roderick Davey; David C Salonen
Journal:  Skeletal Radiol       Date:  2014-08-12       Impact factor: 2.199

9.  Properties and Corrosion Performance of Self-reinforced Composite PEEK for Proposed Use as a Modular Taper Gasket.

Authors:  Eric S Ouellette; Jeremy L Gilbert
Journal:  Clin Orthop Relat Res       Date:  2016-11       Impact factor: 4.176

Review 10.  Do retrieval analysis and blood metal measurements contribute to our understanding of adverse local tissue reactions?

Authors:  Patricia A Campbell; Michael S Kung; Andrew R Hsu; Joshua J Jacobs
Journal:  Clin Orthop Relat Res       Date:  2014-12       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.