Literature DB >> 8300685

Corrosion and wear at the modular interface of uncemented femoral stems.

S D Cook1, R L Barrack, A J Clemow.   

Abstract

We examined 108 uncemented femoral stems with modular femoral heads which had been retrieved for reasons other than loosening. There were detectable amounts of wear and corrosion in 10 of 29 (34.5%) mixed-alloy components and 7 of 79 (9%) single-alloy components after a mean implantation time of 25 months. We found no correlation between the presence or extent of corrosion or surface damage and any of time in situ, initial diagnosis, reason for removal, age, or weight. Stems with wear and corrosion were less likely to show histological bony ingrowth. The interface between the head and stem of modular total hip components is a possible source of ion release and wear debris, but wear and corrosion were totally absent in most specimens. This suggests that this problem could be avoided, and that further research is required to develop manufacturing methods which would minimise such changes.

Mesh:

Substances:

Year:  1994        PMID: 8300685

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  12 in total

1.  Stability and trunnion wear potential in large-diameter metal-on-metal total hips: a finite element analysis.

Authors:  Jacob M Elkins; John J Callaghan; Thomas D Brown
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

2.  Modern trunnions are more flexible: a mechanical analysis of THA taper designs.

Authors:  David A Porter; Robert M Urban; Joshua J Jacobs; Jeremy L Gilbert; José A Rodriguez; H John Cooper
Journal:  Clin Orthop Relat Res       Date:  2014-09-30       Impact factor: 4.176

3.  Stem-Sleeve Junction Failure of a Modular Femoral Hip System: a Retrieval Analysis.

Authors:  Feras Waly; Fahad H Abduljabbar; Trevor Gascoyne; Thomas R Turgeon; Olga Huk
Journal:  HSS J       Date:  2015-07-09

4.  Severe metal-induced osteolysis many years after unipolar hip endoprosthesis.

Authors:  Matthew A Mann; Dylan Tanzer; Michael Tanzer
Journal:  Clin Orthop Relat Res       Date:  2013-01-05       Impact factor: 4.176

5.  Proximal component modularity in THA--at what cost? An implant retrieval study.

Authors:  A M Kop; C Keogh; E Swarts
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

6.  Otto Aufranc Award: Large Heads Do Not Increase Damage at the Head-neck Taper of Metal-on-polyethylene Total Hip Arthroplasties.

Authors:  Georgios K Triantafyllopoulos; Marcella E Elpers; Jayme C Burket; Christina I Esposito; Douglas E Padgett; Timothy M Wright
Journal:  Clin Orthop Relat Res       Date:  2016-02       Impact factor: 4.176

7.  A stature-specific concept for uncemented, primary total hip arthroplasty.

Authors:  Georg W Omlor; Hannah Ullrich; Knut Krahmer; Alexander Jung; Günther Aldinger; Peter Aldinger
Journal:  Acta Orthop       Date:  2010-02       Impact factor: 3.717

8.  Adverse local tissue reaction arising from corrosion at the femoral neck-body junction in a dual-taper stem with a cobalt-chromium modular neck.

Authors:  H John Cooper; Robert M Urban; Richard L Wixson; R Michael Meneghini; Joshua J Jacobs
Journal:  J Bone Joint Surg Am       Date:  2013-05-15       Impact factor: 5.284

9.  Corrosion at the head-neck taper as a cause for adverse local tissue reactions after total hip arthroplasty.

Authors:  H John Cooper; Craig J Della Valle; Richard A Berger; Matthew Tetreault; Wayne G Paprosky; Scott M Sporer; Joshua J Jacobs
Journal:  J Bone Joint Surg Am       Date:  2012-09-19       Impact factor: 5.284

10.  A case of a C-stem fracture at the head-neck junction and a review of the literature.

Authors:  David Morley; Ian Starks; Justin Lim
Journal:  Case Rep Orthop       Date:  2012-12-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.