Literature DB >> 7554653

Complications of femoral and acetabular modularity.

E A Salvati1, J R Lieberman, O L Huk, B G Evans.   

Abstract

The versatility of modular total hip arthroplasties have rapidly extended their applications. However, these new interfaces can lead to complications that were not observed with monolithic components. These problems have been noted with modular femoral and acetabular components and have been associated with the generation of particulate debris. This article reviews the authors' clinical observations and histologic, biomechanic, and spectophotometric evaluations of modular total hip arthroplasties. New data comparing both synovial fluid metal levels in well-fixed and loose monolithic and modular prosthetic hip implants are presented. In modular total hip components, synovial fluid cobalt levels correlated positively with patient weight and length of implantation. The generation of particulate debris in modular total hip components may induce periprosthetic osteolysis. Taper locks for femoral components and locking mechanisms for the polyethylene liner and metallic cup must be designed to avoid the production of particulate debris.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7554653

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  7 in total

1.  Early polyethylene wear and osteolysis with ABG acetabular cups (7- to 12-year follow-up).

Authors:  Sachin Badhe; Peter Livesley
Journal:  Int Orthop       Date:  2005-11-08       Impact factor: 3.075

2.  Component version in modular total hip revision.

Authors:  Michael A Kopec; Aaron Pemberton; Joseph C Milbrandt; Gordon Allan
Journal:  Iowa Orthop J       Date:  2009

3.  Osteolysis of the femur at the junction of a modular intramedullary nail. A case report.

Authors:  D M Jones; J L Marsh
Journal:  Iowa Orthop J       Date:  1998

4.  Proximal component modularity in THA--at what cost? An implant retrieval study.

Authors:  A M Kop; C Keogh; E Swarts
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

5.  [On the biomechanics of the hip: relevance of femoral anteversion for hip contact force and loading using a short-stemmed prostheses].

Authors:  S W Tohtz; M O Heller; W R Taylor; C Perka; G N Duda
Journal:  Orthopade       Date:  2008-09       Impact factor: 1.087

6.  Late Nontraumatic Dissociation of the Femoral Head and Trunnion in a Total Hip Arthroplasty.

Authors:  Simon J M Parker; Wasim Khan; Simon Mellor
Journal:  Case Rep Orthop       Date:  2015-05-11

7.  Uncemented femoral revision arthroplasty using a modular tapered, fluted titanium stem: 5- to 16-year results of 163 cases.

Authors:  Dieter C Wirtz; Sascha Gravius; Rudolf Ascherl; Miguel Thorweihe; Raimund Forst; Ulrich Noeth; Uwe M Maus; Matthias D Wimmer; Günther Zeiler; Moritz C Deml
Journal:  Acta Orthop       Date:  2014-09-01       Impact factor: 3.717

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.