An accelerated cyclic loading corrosion test was used to determine the corrosion behavior of a commercial (GSP) and a prototype titanium hip prosthesis each with a modular neck. Four GSP and four prototype stems were subjected to a 2-Hz cyclic load ranging between 200 and 2,100 N for 1,000,000 cycles. Three stems were tested in an environment of FeCl3 solution, three stems were tested in Ringer's solution, and two stems were tested in air. After cyclic loading, the specimens were carefully examined with optical and scanning electron microscopy (SEM). None of them showed macroscopic or microscopic signs of corrosion, regardless of the environment to which the specimens were subjected. However, macroscopic evidence of mechanical fretting was present at the neck-stem modular junction, primarily concentrated at the medial contact point between stem and neck, especially for the prototype stems. SEM analysis confirmed these observations. The appreciable differences observed between the two designs suggest that the problem can be minimized or eliminated with an accurately designed taper fitting.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 9019482     DOI: 10.1002/(SICI)1097-4636(199602)30:2<181::AID-JBM7>3.0.CO;2-N

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  15 in total

1.  Assessment of wear on the cones of modular stainless steel Exeter hip stems.

Authors:  R P S Chaplin; A J C Lee; R M Hooper
Journal:  J Mater Sci Mater Med       Date:  2004-09       Impact factor: 3.896

2.  Fracture of a modular femoral neck after total hip arthroplasty: a case report.

Authors:  Geoffrey Wright; Scott Sporer; Robert Urban; Joshua Jacobs
Journal:  J Bone Joint Surg Am       Date:  2010-06       Impact factor: 5.284

3.  New technology: safety, efficacy, and learning curves.

Authors:  Paul J Duwelius; Javad Parvizi; Laura Matsen Ko
Journal:  Clin Orthop Relat Res       Date:  2013-12-07       Impact factor: 4.176

4.  Stem-Sleeve Junction Failure of a Modular Femoral Hip System: a Retrieval Analysis.

Authors:  Feras Waly; Fahad H Abduljabbar; Trevor Gascoyne; Thomas R Turgeon; Olga Huk
Journal:  HSS J       Date:  2015-07-09

5.  Proximal component modularity in THA--at what cost? An implant retrieval study.

Authors:  A M Kop; C Keogh; E Swarts
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

6.  A stature-specific concept for uncemented, primary total hip arthroplasty.

Authors:  Georg W Omlor; Hannah Ullrich; Knut Krahmer; Alexander Jung; Günther Aldinger; Peter Aldinger
Journal:  Acta Orthop       Date:  2010-02       Impact factor: 3.717

7.  Adverse local tissue reaction arising from corrosion at the femoral neck-body junction in a dual-taper stem with a cobalt-chromium modular neck.

Authors:  H John Cooper; Robert M Urban; Richard L Wixson; R Michael Meneghini; Joshua J Jacobs
Journal:  J Bone Joint Surg Am       Date:  2013-05-15       Impact factor: 5.284

8.  High Risk of Failure With Bimodular Femoral Components in THA.

Authors:  Aidin Eslam Pour; Robert Borden; Takayuki Murayama; Mary Groll-Brown; J David Blaha
Journal:  Clin Orthop Relat Res       Date:  2015-09-01       Impact factor: 4.176

9.  Metal release and corrosion effects of modular neck total hip arthroplasty.

Authors:  J Philippe Kretzer; Eike Jakubowitz; Michael Krachler; Marc Thomsen; Christian Heisel
Journal:  Int Orthop       Date:  2009-02-14       Impact factor: 3.075

10.  Modular titanium alloy neck adapter failures in hip replacement--failure mode analysis and influence of implant material.

Authors:  Thomas M Grupp; Thomas Weik; Wilhelm Bloemer; Hanns-Peter Knaebel
Journal:  BMC Musculoskelet Disord       Date:  2010-01-04       Impact factor: 2.362

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.