Literature DB >> 21860542

Capacitive micromachined ultrasonic transducers for medical imaging and therapy.

Butrus T Khuri-Yakub1, Omer Oralkan.   

Abstract

Capacitive micromachined ultrasonic transducers (CMUTs) have been subject to extensive research for the last two decades. Although they were initially developed for air-coupled applications, today their main application space is medical imaging and therapy. This paper first presents a brief description of CMUTs, their basic structure, and operating principles. Our progression of developing several generations of fabrication processes is discussed with an emphasis on the advantages and disadvantages of each process. Monolithic and hybrid approaches for integrating CMUTs with supporting integrated circuits are surveyed. Several prototype transducer arrays with integrated frontend electronic circuits we developed and their use for 2-D and 3-D, anatomical and functional imaging, and ablative therapies are described. The presented results prove the CMUT as a MEMS technology for many medical diagnostic and therapeutic applications.

Entities:  

Year:  2011        PMID: 21860542      PMCID: PMC3158704          DOI: 10.1088/0960-1317/21/5/054004

Source DB:  PubMed          Journal:  J Micromech Microeng        ISSN: 0960-1317            Impact factor:   1.881


  23 in total

1.  Characterization of one-dimensional capacitive micromachined ultrasonic immersion transducer arrays.

Authors:  X Jin; O Oralkan; F L Degertekin; B T Khuri-Yakub
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2001-05       Impact factor: 2.725

2.  Capacitive micromachined ultrasonic transducers: next-generation arrays for acoustic imaging?

Authors:  Omer Oralkan; A Sanli Ergun; Jeremy A Johnson; Mustafa Karaman; Utkan Demirci; Kambiz Kaviani; Thomas H Lee; Butrus T Khuri-Yakub
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2002-11       Impact factor: 2.725

3.  Volumetric ultrasound imaging using 2-D CMUT arrays.

Authors:  Omer Oralkan; A Sanli Ergun; Ching-Hsiang Cheng; Jeremy A Johnson; Mustafa Karaman; Thomas H Lee; Butrus T Khuri-Yakub
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2003-11       Impact factor: 2.725

4.  Capacitive micromachined ultrasonic transducers: fabrication technology.

Authors:  Arif Sanli Ergun; Yongli Huang; Xuefeng Zhuang; Omer Oralkan; Goksen G Yaralioglu; Butrus T Khuri-Yakub
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2005-12       Impact factor: 2.725

5.  Finite-element analysis of capacitive micromachined ultrasonic transducers.

Authors:  Goksen G Yaralioglu; A Sanli Ergun; Butrus T Khuri-Yakub
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2005-12       Impact factor: 2.725

6.  Integration of 2D CMUT arrays with front-end electronics for volumetric ultrasound imaging.

Authors:  Ira O Wygant; Xuefeng Zhuang; David T Yeh; Omer Oralkan; A Sanli Ergun; Mustafa Karaman; Butrus T Khuri-Yakub
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008-02       Impact factor: 2.725

7.  Theory and analysis of electrode size optimization for capacitive microfabricated ultrasonic transducers.

Authors:  A Bozkurt; I Ladabaum; A Atalar; B T Khuri-Yakub
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1999       Impact factor: 2.725

8.  Capacitive micromachined ultrasonic transducers with piston-shaped membranes: fabrication and experimental characterization.

Authors:  Yongli Huang; Xuefeng Zhuang; Edward O Haeggstrom; A Sanli Ergun; Ching-Hsiang Cheng; Butrus T Khuri-Yakub
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-01       Impact factor: 2.725

9.  CMUT Fabrication Based On A Thick Buried Oxide Layer.

Authors:  Mario Kupnik; Srikant Vaithilingam; Kazutoshi Torashima; Ira O Wygant; Butrus T Khuri-Yakub
Journal:  Proc IEEE Ultrason Symp       Date:  2010-10

10.  Finite element modeling and experimental characterization of crosstalk in 1-D CMUT arrays.

Authors:  Baris Bayram; Mario Kupnik; Goksen G Yaralioglu; Omer Oralkan; Arif Sanli Ergun; Der-Song Lin; Serena H Wong; Butrus T Khuri-Yakub
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2007-02       Impact factor: 2.725

View more
  30 in total

1.  A Fast-Switching (1.35-μs) Low-Control-Voltage (2.5-V) MEMS T/R Switch Monolithically Integrated With a Capacitive Micromachined Ultrasonic Transducer (CMUT).

Authors:  Xiao Zhang; Oluwafemi Joel Adelegan; Feysel Yalçın Yamaner; Ömer Oralkan
Journal:  J Microelectromech Syst       Date:  2018-01-11       Impact factor: 2.417

2.  A capacitive ultrasonic transducer based on parametric resonance.

Authors:  Sushruta Surappa; Sarp Satir; F Levent Degertekin
Journal:  Appl Phys Lett       Date:  2017-07-24       Impact factor: 3.791

3.  Low Temperature CMUT Fabrication Process with Dielectric Lift-off Membrane Support for Improved Reliability.

Authors:  Amirabbas Pirouz; F Levent Degertekin
Journal:  J Micromech Microeng       Date:  2018-05-08       Impact factor: 1.881

4.  CMUTs with high-K atomic layer deposition dielectric material insulation layer.

Authors:  Toby Xu; Coskun Tekes; F Degertekin
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-12       Impact factor: 2.725

5.  Ex Vivo HIFU Experiments Using a $32 \times 32$ -Element CMUT Array.

Authors:  Hyo-Seon Yoon; Chienliu Chang; Ji Hoon Jang; Anshuman Bhuyan; Jung Woo Choe; Amin Nikoozadeh; Ronald D Watkins; Douglas N Stephens; Kim Butts Pauly; Butrus T Khuri-Yakub
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-12       Impact factor: 2.725

6.  Supply-Inverted Bipolar Pulser and Tx/Rx Switch for CMUTs Above the Process Limit for High Pressure Pulse Generation.

Authors:  Gwangrok Jung; Amirabbas Pirouz; Coskun Tekes; Thomas M Carpenter; David Cowell; Steven Freear; Maysam Ghovanloo; F Levent Degertekin
Journal:  IEEE Sens J       Date:  2019-08-28       Impact factor: 3.301

Review 7.  Point-of-care (POC) devices by means of advanced MEMS.

Authors:  Stanislav L Karsten; Mehmet C Tarhan; Lili C Kudo; Dominique Collard; Hiroyuki Fujita
Journal:  Talanta       Date:  2015-04-23       Impact factor: 6.057

8.  High-Frequency Ultrasound Array Designed for Ultrasound-Guided Breast Biopsy.

Authors:  Thomas Cummins; Payam Eliahoo; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-03-31       Impact factor: 2.725

9.  Supply-Doubled Pulse-Shaping High Voltage Pulser for CMUT Arrays.

Authors:  Gwangrok Jung; Coskun Tekes; Amirabbas Pirouz; F Levent Degertekin; Maysam Ghovanloo
Journal:  IEEE Trans Circuits Syst II Express Briefs       Date:  2017-04-06       Impact factor: 3.292

10.  Singulation for imaging ring arrays of capacitive micromachined ultrasonic transducers.

Authors:  Chienliu Chang; Azadeh Moini; Amin Nikoozadeh; Ali Fatih Sarioglu; Nikhil Apte; Xuefeng Zhuang; Butrus T Khuri-Yakub
Journal:  J Micromech Microeng       Date:  2014-09-17       Impact factor: 1.881

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.