High-Frequency Ultrasound Array Designed for Ultrasound-Guided Breast Biopsy.

Thomas Cummins, Payam Eliahoo, K Kirk Shung.   

Abstract

This paper describes the development of a miniaturized high-frequency linear array that can be integrated within a core biopsy needle to improve tissue sampling accuracy during breast cancer biopsy procedures. The 64-element linear array has an element width of [Formula: see text], kerf width of [Formula: see text], element length of 1 mm, and element thickness of [Formula: see text]. The 2-2 array composite was fabricated using deep reactive ion etching of lead magnesium niobate-lead titanate (PMN-PT) single crystal material. The array composite fabrication process as well as a novel high-density electrical interconnect solution are presented and discussed. Array performance measurements show that the array had a center frequency and fractional bandwidth ([Formula: see text]) of 59.1 MHz and 29.4%, respectively. Insertion loss and adjacent element crosstalk at the center frequency were -41.0 and [Formula: see text], respectively. A B-mode image of a tungsten wire target phantom was captured using a synthetic aperture imaging system and the imaging test results demonstrate axial and lateral resolutions of 33.2 and [Formula: see text], respectively.

Entities:  

Mesh:

Year:  2016        PMID: 27046895      PMCID: PMC4900172          DOI: 10.1109/TUFFC.2016.2548993

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  18 in total

1.  Interdigital pair bonding for high frequency (20-50 MHz) ultrasonic composite transducers.

Authors:  R Liu; K A Harasiewicz; F S Foster
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2001-01       Impact factor: 2.725

2.  Volumetric ultrasound imaging using 2-D CMUT arrays.

Authors:  Omer Oralkan; A Sanli Ergun; Ching-Hsiang Cheng; Jeremy A Johnson; Mustafa Karaman; Thomas H Lee; Butrus T Khuri-Yakub
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2003-11       Impact factor: 2.725

Review 3.  Image-guided breast biopsy: state-of-the-art.

Authors:  E A M O'Flynn; A R M Wilson; M J Michell
Journal:  Clin Radiol       Date:  2010-04       Impact factor: 2.350

4.  Fabrication and performance of a miniaturized 64-element high-frequency endoscopic phased array.

Authors:  Andre Bezanson; Rob Adamson; Jeremy Brown
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-01       Impact factor: 2.725

5.  Real-time endobronchial ultrasound guided transbronchial needle aspiration for sampling mediastinal lymph nodes.

Authors:  F J F Herth; R Eberhardt; P Vilmann; M Krasnik; A Ernst
Journal:  Thorax       Date:  2006-05-31       Impact factor: 9.139

6.  Capacitive micromachined ultrasonic transducers for medical imaging and therapy.

Authors:  Butrus T Khuri-Yakub; Omer Oralkan
Journal:  J Micromech Microeng       Date:  2011-05       Impact factor: 1.881

7.  New fabrication of high-frequency (100-MHz) ultrasound PZT film kerfless linear array.

Authors:  Benpeng Zhu; Ngai Yui Chan; Jiyan Dai; K Kirk Shung; Shinichi Takeuchi; Qifa Zhou
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-04       Impact factor: 2.725

8.  Micro-machined high-frequency (80 MHz) PZT thick film linear arrays.

Authors:  Qifa Zhou; Dawei Wu; Changgeng Liu; Benpeng Zhu; Frank Djuth; K Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2010-10       Impact factor: 2.725

Review 9.  Missed breast cancers at US-guided core needle biopsy: how to reduce them.

Authors:  Ji Hyun Youk; Eun-Kyung Kim; Min Jung Kim; Ji Young Lee; Ki Keun Oh
Journal:  Radiographics       Date:  2007 Jan-Feb       Impact factor: 5.333

10.  Micromachining techniques in developing high-frequency piezoelectric composite ultrasonic array transducers.

Authors:  Changgeng Liu; Frank T Djuth; Qifa Zhou; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-12       Impact factor: 2.725

View more
  2 in total

1.  Analysis and Design of High-Frequency 1-D CMUT Imaging Arrays in Noncollapsed Mode.

Authors:  Evren Fatih Arkan; F Levent Degertekin
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-12-17       Impact factor: 2.725

2.  A Micromachined Pb(Mg1/3Nb2/3)O3-PbTiO3 Single Crystal Composite Circular Array for Intravascular Ultrasound Imaging.

Authors:  Sibo Li; Jian Tian; Xiaoning Jiang
Journal:  J Eng Sci Med Diagn Ther       Date:  2019-01-18
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.