Literature DB >> 11381699

Characterization of one-dimensional capacitive micromachined ultrasonic immersion transducer arrays.

X Jin1, O Oralkan, F L Degertekin, B T Khuri-Yakub.   

Abstract

In this paper, we report on the characterization of 1-D arrays of capacitive micromachined ultrasonic transducers (cMUT). A 275- x 5600-micron 1-D CMUT array element is experimentally characterized, and the results are found to be in agreement with theoretical predictions. As a receiver, the transducer has a 0.28-fm/square root of Hz displacement sensitivity, and, as a transmitter, it produces 5 kPa/V of output pressure at the transducer surface at 3 MHz with a DC bias of 35 V. The transducer has more than 100% fractional bandwidth around 3 MHz, which makes it suitable for ultrasound imaging. The radiation pattern of isolated single elements, as well as those of array elements are measured, and two major sources of acoustical cross talk are identified. A weakly dispersive non-leaky interface wave (Stoneley wave) is observed to be propagating at the silicon substrate-fluid interface at a speed close to the speed of sound in the fluid. This wave causes internal reflections, spurious resonance, and radiation from the edges of the silicon substrate. The large lateral component of the particle velocity generated by the membranes at the edge of the cMUT array elements is found to be the source of this interface wave. Lowest order Lamb waves in the silicon substrate are also found to contribute to the cross talk between elements. These waves are excited at the edges of individual vibrating membranes, where they are anchored to the substrate, and result in a narrowing of the beam profile of the array elements. Several methods, such as trench isolation and wafer thinning, are proposed and implemented to modify the acoustical cross coupling between array elements.

Entities:  

Year:  2001        PMID: 11381699     DOI: 10.1109/58.920706

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  10 in total

1.  A capacitive ultrasonic transducer based on parametric resonance.

Authors:  Sushruta Surappa; Sarp Satir; F Levent Degertekin
Journal:  Appl Phys Lett       Date:  2017-07-24       Impact factor: 3.791

Review 2.  Image-guided ultrasound phased arrays are a disruptive technology for non-invasive therapy.

Authors:  Kullervo Hynynen; Ryan M Jones
Journal:  Phys Med Biol       Date:  2016-08-05       Impact factor: 3.609

3.  Capacitive micromachined ultrasonic transducer arrays as tunable acoustic metamaterials.

Authors:  Shane W Lani; M Wasequr Rashid; Jennifer Hasler; Karim G Sabra; F Levent Degertekin
Journal:  Appl Phys Lett       Date:  2014-02-07       Impact factor: 3.791

4.  Wideband acoustic activation and detection of droplet vaporization events using a capacitive micromachined ultrasonic transducer.

Authors:  Anthony Novell; Christopher B Arena; Omer Oralkan; Paul A Dayton
Journal:  J Acoust Soc Am       Date:  2016-06       Impact factor: 1.840

5.  Dual-Frequency Piezoelectric Endoscopic Transducer for Imaging Vascular Invasion in Pancreatic Cancer.

Authors:  Brooks D Lindsey; Jinwook Kim; Paul A Dayton; Xiaoning Jiang
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2017-05-08       Impact factor: 2.725

6.  Capacitive micromachined ultrasonic transducers for medical imaging and therapy.

Authors:  Butrus T Khuri-Yakub; Omer Oralkan
Journal:  J Micromech Microeng       Date:  2011-05       Impact factor: 1.881

7.  Development of Dual-Frequency PMUT Arrays Based on Thin Ceramic PZT for Endoscopic Photoacoustic Imaging.

Authors:  Haoran Wang; Hao Yang; Zhenfang Chen; Qincheng Zheng; Huabei Jiang; Philip X-L Feng; Huikai Xie
Journal:  J Microelectromech Syst       Date:  2021-07-26       Impact factor: 2.829

8.  Two Capacitive Micro-Machined Ultrasonic Transducers for Wind Speed Measurement.

Authors:  Gia Thinh Bui; Yu-Tsung Jiang; Da-Chen Pang
Journal:  Sensors (Basel)       Date:  2016-06-02       Impact factor: 3.576

9.  Quantitative comparison of PZT and CMUT probes for photoacoustic imaging: Experimental validation.

Authors:  Maëva Vallet; François Varray; Jérôme Boutet; Jean-Marc Dinten; Giosuè Caliano; Alessandro Stuart Savoia; Didier Vray
Journal:  Photoacoustics       Date:  2017-09-22

Review 10.  A Review on Analytical Modeling for Collapse Mode Capacitive Micromachined Ultrasonic Transducer of the Collapse Voltage and the Static Membrane Deflections.

Authors:  JiuJiang Wang; Xin Liu; YuanYu Yu; Yao Li; ChingHsiang Cheng; Shuang Zhang; PengUn Mak; MangI Vai; SioHang Pun
Journal:  Micromachines (Basel)       Date:  2021-06-18       Impact factor: 2.891

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.