Literature DB >> 25474786

CMUTs with high-K atomic layer deposition dielectric material insulation layer.

Toby Xu, Coskun Tekes, F Degertekin.   

Abstract

Use of high-κ dielectric, atomic layer deposition (ALD) materials as an insulation layer material for capacitive micromachined ultrasonic transducers (CMUTs) is investigated. The effect of insulation layer material and thickness on CMUT performance is evaluated using a simple parallel plate model. The model shows that both high dielectric constant and the electrical breakdown strength are important for the dielectric material, and significant performance improvement can be achieved, especially as the vacuum gap thickness is reduced. In particular, ALD hafnium oxide (HfO2) is evaluated and used as an improvement over plasma-enhanced chemical vapor deposition (PECVD) silicon nitride (Six)Ny)) for CMUTs fabricated by a low-temperature, complementary metal oxide semiconductor transistor-compatible, sacrificial release method. Relevant properties of ALD HfO2) such as dielectric constant and breakdown strength are characterized to further guide CMUT design. Experiments are performed on parallel fabricated test CMUTs with 50-nm gap and 16.5-MHz center frequency to measure and compare pressure output and receive sensitivity for 200-nm PECVD Six)Ny) and 100-nm HfO2) insulation layers. Results for this particular design show a 6-dB improvement in receiver output with the collapse voltage reduced by one-half; while in transmit mode, half the input voltage is needed to achieve the same maximum output pressure.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25474786      PMCID: PMC4258900          DOI: 10.1109/TUFFC.2014.006481

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  14 in total

1.  Calculation and measurement of electromechanical coupling coefficient of capacitive micromachined ultrasonic transducers.

Authors:  Goksen G Yaralioglu; Arif Sanli Ergun; Baris Bayram; Edward Haeggström; Butrus T Khuri-Yakub
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2003-04       Impact factor: 2.725

2.  Deep-collapse operation of capacitive micromachined ultrasonic transducers.

Authors:  Selim Olcum; F Yalcin Yamaner; Ayhan Bozkurt; Abdullah Atalar
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-11       Impact factor: 2.725

3.  CMUTS with dual-electrode structure for improved transmit and receive performance.

Authors:  Rasim O Guldiken; Jeff McLean; F Levent Degertekin
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2006-02       Impact factor: 2.725

4.  An integrated circuit with transmit beamforming flip-chip bonded to a 2-D CMUT array for 3-D ultrasound imaging.

Authors:  Ira O Wygant; Nafis S Jamal; Hyunjoo J Lee; Amin Nikoozadeh; Omer Oralkan; Mustafa Karaman; Butrus T Khuri-Yakub
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-10       Impact factor: 2.725

5.  Volumetric imaging using single chip integrated CMUT-on-CMOS IVUS array.

Authors:  Coskun Tekes; Jaime Zahorian; Gokce Gurun; Sarp Satir; Toby Xu; Michael Hochman; F Levent Degertekin
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2012

6.  Capacitive micromachined ultrasonic transducers for medical imaging and therapy.

Authors:  Butrus T Khuri-Yakub; Omer Oralkan
Journal:  J Micromech Microeng       Date:  2011-05       Impact factor: 1.881

7.  A large-signal model for CMUT arrays with arbitrary membrane geometry operating in non-collapsed mode.

Authors:  Sarp Satir; Jaime Zahorian; F Levent Degertekin
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-11       Impact factor: 2.725

8.  Front-end receiver electronics for high-frequency monolithic CMUT-on-CMOS imaging arrays.

Authors:  Gokce Gurun; Paul Hasler; F Degertekin
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-08       Impact factor: 2.725

9.  Monolithic CMUT-on-CMOS integration for intravascular ultrasound applications.

Authors:  Jaime Zahorian; Michael Hochman; Toby Xu; Sarp Satir; Gokce Gurun; Mustafa Karaman; F Levent Degertekin
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-12       Impact factor: 2.725

10.  Single-chip CMUT-on-CMOS front-end system for real-time volumetric IVUS and ICE imaging.

Authors:  Gokce Gurun; Coskun Tekes; Jaime Zahorian; Toby Xu; Sarp Satir; Mustafa Karaman; Jennifer Hasler; F Levent Degertekin
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-02       Impact factor: 2.725

View more
  6 in total

1.  A capacitive ultrasonic transducer based on parametric resonance.

Authors:  Sushruta Surappa; Sarp Satir; F Levent Degertekin
Journal:  Appl Phys Lett       Date:  2017-07-24       Impact factor: 3.791

2.  Analysis and Design of High-Frequency 1-D CMUT Imaging Arrays in Noncollapsed Mode.

Authors:  Evren Fatih Arkan; F Levent Degertekin
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-12-17       Impact factor: 2.725

Review 3.  Circuits on miniaturized ultrasound imaging system-on-a-chip: a review.

Authors:  Jaemyung Lim
Journal:  Biomed Eng Lett       Date:  2022-05-12

4.  Supply-Inverted Bipolar Pulser and Tx/Rx Switch for CMUTs Above the Process Limit for High Pressure Pulse Generation.

Authors:  Gwangrok Jung; Amirabbas Pirouz; Coskun Tekes; Thomas M Carpenter; David Cowell; Steven Freear; Maysam Ghovanloo; F Levent Degertekin
Journal:  IEEE Sens J       Date:  2019-08-28       Impact factor: 3.301

5.  Supply-Doubled Pulse-Shaping High Voltage Pulser for CMUT Arrays.

Authors:  Gwangrok Jung; Coskun Tekes; Amirabbas Pirouz; F Levent Degertekin; Maysam Ghovanloo
Journal:  IEEE Trans Circuits Syst II Express Briefs       Date:  2017-04-06       Impact factor: 3.292

Review 6.  Advances in Capacitive Micromachined Ultrasonic Transducers.

Authors:  Kevin Brenner; Arif Sanli Ergun; Kamyar Firouzi; Morten Fischer Rasmussen; Quintin Stedman; Butrus Pierre Khuri-Yakub
Journal:  Micromachines (Basel)       Date:  2019-02-23       Impact factor: 2.891

  6 in total