Literature DB >> 14682642

Volumetric ultrasound imaging using 2-D CMUT arrays.

Omer Oralkan1, A Sanli Ergun, Ching-Hsiang Cheng, Jeremy A Johnson, Mustafa Karaman, Thomas H Lee, Butrus T Khuri-Yakub.   

Abstract

Recently, capacitive micromachined ultrasonic transducers (CMUTs) have emerged as a candidate to overcome the difficulties in the realization of 2-D arrays for real-time 3-D imaging. In this paper, we present the first volumetric images obtained using a 2-D CMUT array. We have fabricated a 128 x 128-element 2-D CMUT array with through-wafer via interconnects and a 420-microm element pitch. As an experimental prototype, a 32 x 64-element portion of the 128 x 128-element array was diced and flip-chip bonded onto a glass fanout chip. This chip provides individual leads from a central 16 x 16-element portion of the array to surrounding bondpads. An 8 x 16-element portion of the array was used in the experiments along with a 128-channel data acquisition system. For imaging phantoms, we used a 2.37-mm diameter steel sphere located 10 mm from the array center and two 12-mm-thick Plexiglas plates located 20 mm and 60 mm from the array. A 4 x 4 group of elements in the middle of the 8 x 16-element array was used in transmit, and the remaining elements were used to receive the echo signals. The echo signal obtained from the spherical target presented a frequency spectrum centered at 4.37 MHz with a 100% fractional bandwidth, whereas the frequency spectrum for the echo signal from the parallel plate phantom was centered at 3.44 MHz with a 91% fractional bandwidth. The images were reconstructed by using RF beamforming and synthetic phased array approaches and visualized by surface rendering and multiplanar slicing techniques. The image of the spherical target has been used to approximate the point spread function of the system and is compared with theoretical expectations. This study experimentally demonstrates that 2-D CMUT arrays can be fabricated with high yield using silicon IC-fabrication processes, individual electrical connections can be provided using through-wafer vias, and flip-chip bonding can be used to integrate these dense 2-D arrays with electronic circuits for practical 3-D imaging applications.

Mesh:

Substances:

Year:  2003        PMID: 14682642     DOI: 10.1109/tuffc.2003.1251142

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  27 in total

1.  Volumetric elasticity imaging with a 2-D CMUT array.

Authors:  Ted G Fisher; Timothy J Hall; Satchi Panda; Michael S Richards; Paul E Barbone; Jingfeng Jiang; Jeff Resnick; Steve Barnes
Journal:  Ultrasound Med Biol       Date:  2010-06       Impact factor: 2.998

2.  Photoacoustic technique to measure beam profile of pulsed laser systems.

Authors:  Srivalleesha Mallidi; Stanislav Emelianov
Journal:  Rev Sci Instrum       Date:  2009-05       Impact factor: 1.523

3.  Design Optimization for a 2-D Sparse Transducer Array for 3-D Ultrasound Imaging.

Authors:  Jung Woo Choe; Omer Oralkan; Pierre T Khuri-Yakub
Journal:  Proc IEEE Ultrason Symp       Date:  2010-10-11

4.  Three-dimensional ultrasound scanning.

Authors:  Aaron Fenster; Grace Parraga; Jeff Bax
Journal:  Interface Focus       Date:  2011-06-01       Impact factor: 3.906

5.  Capacitive micromachined ultrasonic transducers for medical imaging and therapy.

Authors:  Butrus T Khuri-Yakub; Omer Oralkan
Journal:  J Micromech Microeng       Date:  2011-05       Impact factor: 1.881

6.  Characterization of a broadband all-optical ultrasound transducer-from optical and acoustical properties to imaging.

Authors:  Yang Hou; Jin-Sung Kim; Sheng-Wen Huang; S Ashkenazi; L J Guo; M O'Donnell
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008-08       Impact factor: 2.725

7.  A dual-layer transducer array for 3-D rectilinear imaging.

Authors:  Jesse T Yen; Chi Hyung Seo; Samer I Awad; Jong S Jeong
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-01       Impact factor: 2.725

8.  A 256 x 256 2-D array transducer with row-column addressing for 3-D rectilinear imaging.

Authors:  Chi Hyung Seo; Jesse T Yen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-04       Impact factor: 2.725

9.  Thin polymer etalon arrays for high-resolution photoacoustic imaging.

Authors:  Yang Hou; Sheng-Wen Huang; Shai Ashkenazi; Russell Witte; Matthew O'Donnell
Journal:  J Biomed Opt       Date:  2008 Nov-Dec       Impact factor: 3.170

10.  Acoustic backscatter and effective scatterer size estimates using a 2D CMUT transducer.

Authors:  W Liu; J A Zagzebski; T J Hall; E L Madsen; T Varghese; M A Kliewer; S Panda; C Lowery; S Barnes
Journal:  Phys Med Biol       Date:  2008-07-17       Impact factor: 3.609

View more