Literature DB >> 27076702

Singulation for imaging ring arrays of capacitive micromachined ultrasonic transducers.

Chienliu Chang1, Azadeh Moini1, Amin Nikoozadeh1, Ali Fatih Sarioglu1, Nikhil Apte1, Xuefeng Zhuang1, Butrus T Khuri-Yakub1.   

Abstract

Singulation of MEMS is a critical step in the transition from wafer-level to die-level devices. As is the case for capacitive micromachined ultrasound transducer (CMUT) ring arrays, an ideal singulation must protect the fragile membranes from the processing environment while maintaining a ring array geometry. The singulation process presented in this paper involves bonding a trench-patterned CMUT wafer onto a support wafer, deep reactive ion etching (DRIE) of the trenches, separating the CMUT wafer from the support wafer and de-tethering the CMUT device from the CMUT wafer. The CMUT arrays fabricated and singulated in this process were ring-shaped arrays, with inner and outer diameters of 5 mm and 10 mm, respectively. The fabricated CMUT ring arrays demonstrate the ability of this method to successfully and safely singulate the ring arrays and is applicable to any arbitrary 2D shaped MEMS device with uspended microstructures, taking advantage of the inherent planar attributes of DRIE.

Entities:  

Keywords:  bonding; capacitive micromachined ultrasonic transducer (CMUT); deep reactive ion etching (DRIE); ring arrays; singulation; tether; ultrasound imaging

Year:  2014        PMID: 27076702      PMCID: PMC4827715          DOI: 10.1088/0960-1317/24/10/107002

Source DB:  PubMed          Journal:  J Micromech Microeng        ISSN: 0960-1317            Impact factor:   1.881


  9 in total

1.  Volumetric ultrasound imaging using 2-D CMUT arrays.

Authors:  Omer Oralkan; A Sanli Ergun; Ching-Hsiang Cheng; Jeremy A Johnson; Mustafa Karaman; Thomas H Lee; Butrus T Khuri-Yakub
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2003-11       Impact factor: 2.725

2.  Forward-viewing CMUT arrays for medical imaging.

Authors:  Utkan Demirci; Arif S Ergun; Omrer Oralkan; Mustafa Karaman; Butrus T Khuri-Yakub
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2004-07       Impact factor: 2.725

3.  A CMUT probe for medical ultrasonography: from microfabrication to system integration.

Authors:  Alessandro Stuart Savoia; Giosuè Calianov; Massimo Pappalardo
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2012-06       Impact factor: 2.725

4.  Capacitive micromachined ultrasonic transducers: fabrication technology.

Authors:  Arif Sanli Ergun; Yongli Huang; Xuefeng Zhuang; Omer Oralkan; Goksen G Yaralioglu; Butrus T Khuri-Yakub
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2005-12       Impact factor: 2.725

5.  Integration of 2D CMUT arrays with front-end electronics for volumetric ultrasound imaging.

Authors:  Ira O Wygant; Xuefeng Zhuang; David T Yeh; Omer Oralkan; A Sanli Ergun; Mustafa Karaman; Butrus T Khuri-Yakub
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008-02       Impact factor: 2.725

6.  Minimally redundant 2-D array designs for 3-D medical ultrasound imaging.

Authors:  Mustafa Karaman; Ira O Wygant; Omer Oralkan; Butrus T Khuri-Yakub
Journal:  IEEE Trans Med Imaging       Date:  2009-01-06       Impact factor: 10.048

7.  Packaging and modular assembly of large-area and fine-pitch 2-D ultrasonic transducer arrays.

Authors:  Der-Song Lin; Robert Wodnicki; Xuefeng Zhuang; Charles Woychik; Kai E Thomenius; Rayette A Fisher; David M Mills; Albert J Byun; William Burdick; Pierre Khuri-Yakub; Barry Bonitz; Todd Davies; Glen Thomas; Bernd Otto; Michael Töpper; Thomas Fritzsch; Oswin Ehrmann
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-07       Impact factor: 2.725

8.  Capacitive micromachined ultrasonic transducers for medical imaging and therapy.

Authors:  Butrus T Khuri-Yakub; Omer Oralkan
Journal:  J Micromech Microeng       Date:  2011-05       Impact factor: 1.881

9.  Multifunctional catheters combining intracardiac ultrasound imaging and electrophysiology sensing.

Authors:  D N Stephens; J Cannata; Ruibin Liu; Jian Zhong Zhao; K K Shung; Hien Nguyen; R Chia; A Dentinger; D Wildes; K E Thomenius; A Mahajan; K Shivkumar; Kang Kim; M O'Donnell; A Nikoozadeh; O Oralkan; P T Khuri-Yakub; D J Sahn
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008-07       Impact factor: 2.725

  9 in total
  2 in total

Review 1.  Gastrointestinal diagnosis using non-white light imaging capsule endoscopy.

Authors:  Gerard Cummins; Benjamin F Cox; Gastone Ciuti; Thineskrishna Anbarasan; Marc P Y Desmulliez; Sandy Cochran; Robert Steele; John N Plevris; Anastasios Koulaouzidis
Journal:  Nat Rev Gastroenterol Hepatol       Date:  2019-07       Impact factor: 46.802

2.  A Wearable Ultrasonic Neurostimulator - Part I: A 1D CMUT Phased Array System for Chronic Implantation in Small Animals.

Authors:  Chunkyun Seok; Feysel Yalcin Yamaner; Mesut Sahin; Omer Oralkan
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2021-09-15       Impact factor: 5.234

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.