Literature DB >> 22685377

CMUT Fabrication Based On A Thick Buried Oxide Layer.

Mario Kupnik1, Srikant Vaithilingam, Kazutoshi Torashima, Ira O Wygant, Butrus T Khuri-Yakub.   

Abstract

We introduce a versatile fabrication process for direct wafer-bonded CMUTs. The objective is a flexible fabrication platform for single element transducers, 1D and 2D arrays, and reconfigurable arrays. The main process features are: A low number of litho masks (five for a fully populated 2D array); a simple fabrication sequence on standard MEMS tools without complicated wafer handling (carrier wafers); an improved device reliability; a wide design space in terms of operation frequency and geometric parameters (cell diameter, gap height, effective insulation layer thickness); and a continuous front face of the transducer (CMUT plate) that is connected to ground (shielding for good SNR and human safety in medical applications). All of this is achieved by connecting the hot electrodes individually through a thick buried oxide layer, i.e. from the handle layer of an SOI substrate to silicon electrodes located in each CMUT cell built in the device layer. Vertical insulation trenches are used to isolate these silicon electrodes from the rest of the substrate. Thus, the high electric field is only present where required - in the evacuated gap region of the device and not in the insulation layer of the post region. Array elements (1D and 2D) are simply defined be etching insulation trenches into the handle wafer of the SOI substrate.

Entities:  

Year:  2010        PMID: 22685377      PMCID: PMC3370668          DOI: 10.1109/ULTSYM.2010.5935935

Source DB:  PubMed          Journal:  Proc IEEE Ultrason Symp        ISSN: 1051-0117


  4 in total

1.  Capacitive micromachined ultrasonic transducers: fabrication technology.

Authors:  Arif Sanli Ergun; Yongli Huang; Xuefeng Zhuang; Omer Oralkan; Goksen G Yaralioglu; Butrus T Khuri-Yakub
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2005-12       Impact factor: 2.725

2.  Wafer-bonded 2-D CMUT arrays incorporating through-wafer trench-isolated interconnects with a supporting frame.

Authors:  Xuefeng Zhuang; Ira O Wygant; Der-Song Lin; Mario Kupnik; Omer Oralkan; Butrus T Khuri-Yakub
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-01       Impact factor: 2.725

3.  FEA of CMUTs Suitable for Wide Gas Pressure Range Applications.

Authors:  Min-Chieh Ho; Mario Kupnik; Butrus T Khuri-Yakub
Journal:  Proc IEEE Ultrason Symp       Date:  2010-10-11

4.  CMUT With Substrate-Embedded Springs For Non-Flexural Plate Movement.

Authors:  Amin Nikoozadeh; Pierre T Khuri-Yakub
Journal:  Proc IEEE Ultrason Symp       Date:  2010
  4 in total
  4 in total

1.  FEA of CMUTs Suitable for Wide Gas Pressure Range Applications.

Authors:  Min-Chieh Ho; Mario Kupnik; Butrus T Khuri-Yakub
Journal:  Proc IEEE Ultrason Symp       Date:  2010-10-11

2.  Capacitive micromachined ultrasonic transducers for medical imaging and therapy.

Authors:  Butrus T Khuri-Yakub; Omer Oralkan
Journal:  J Micromech Microeng       Date:  2011-05       Impact factor: 1.881

Review 3.  Advances in Capacitive Micromachined Ultrasonic Transducers.

Authors:  Kevin Brenner; Arif Sanli Ergun; Kamyar Firouzi; Morten Fischer Rasmussen; Quintin Stedman; Butrus Pierre Khuri-Yakub
Journal:  Micromachines (Basel)       Date:  2019-02-23       Impact factor: 2.891

Review 4.  Capacitive Based Micromachined Resonators for Low Level Mass Detection.

Authors:  Muhammad Umair Nathani; Haleh Nazemi; Calvin Love; Yameema Babu Lopez; Siddharth Swaminathan; Arezoo Emadi
Journal:  Micromachines (Basel)       Date:  2020-12-25       Impact factor: 2.891

  4 in total