Literature DB >> 23243630

Precompensation for mutual coupling between array elements in parallel excitation.

Yong Pang1, Xiaoliang Zhang.   

Abstract

Parallel transmission or excitation has been suggested to perform multi-dimensional spatial selective excitation to shorten the pulse width using a coil array and the sensitivity information. The mutual coupling between array elements has been a critical technical issue in RF array designs, which can cause artifacts on the excitation profile, leading to degraded excitation performance and image quality. In this work, a precompensation method is proposed to address the mutual coupling effect in parallel transmission by introducing the mutual coupling coefficient matrix into the RF pulses design procedure of the parallel transmission. 90° RF pulses have been designed using both the original transmit SENSE method and the proposed precompensation method for RF arrays with non-negligible mutual coupling, and their excitation profiles are generated by simulating the Bloch equation. The results show that the mutual coupling effect can be effectively compensated by using the proposed method, yielding enhanced tolerance to insufficient mutual decoupling of RF arrays in parallel excitation, ultimately, providing improved performance and accuracy of parallel excitation.

Entities:  

Year:  2011        PMID: 23243630      PMCID: PMC3496487          DOI: 10.3978/j.issn.2223-4292.2011.11.02

Source DB:  PubMed          Journal:  Quant Imaging Med Surg        ISSN: 2223-4306


  42 in total

1.  Microstrip RF surface coil design for extremely high-field MRI and spectroscopy.

Authors:  X Zhang; K Ugurbil; W Chen
Journal:  Magn Reson Med       Date:  2001-09       Impact factor: 4.668

2.  Analysis of wave behavior in lossy dielectric samples at high field.

Authors:  Qing X Yang; Jinghua Wang; Xiaoliang Zhang; Christopher M Collins; Michael B Smith; Haiying Liu; Xiao-Hong Zhu; J Thomas Vaughan; Kamil Ugurbil; Wei Chen
Journal:  Magn Reson Med       Date:  2002-05       Impact factor: 4.668

3.  Coupling and decoupling theory and its application to the MRI phased array.

Authors:  Ray F Lee; Randy O Giaquinto; Christopher J Hardy
Journal:  Magn Reson Med       Date:  2002-07       Impact factor: 4.668

4.  Eight-channel phased array coil and detunable TEM volume coil for 7 T brain imaging.

Authors:  G C Wiggins; A Potthast; C Triantafyllou; C J Wiggins; L L Wald
Journal:  Magn Reson Med       Date:  2005-07       Impact factor: 4.668

5.  Spatial domain method for the design of RF pulses in multicoil parallel excitation.

Authors:  William Grissom; Chun-yu Yip; Zhenghui Zhang; V Andrew Stenger; Jeffrey A Fessler; Douglas C Noll
Journal:  Magn Reson Med       Date:  2006-09       Impact factor: 4.668

6.  Parallel RF transmission with eight channels at 3 Tesla.

Authors:  Kawin Setsompop; Lawrence L Wald; Vijayanand Alagappan; Borjan Gagoski; Franz Hebrank; Ulrich Fontius; Franz Schmitt; Elfar Adalsteinsson
Journal:  Magn Reson Med       Date:  2006-11       Impact factor: 4.668

7.  Reduction of transmitter B1 inhomogeneity with transmit SENSE slice-select pulses.

Authors:  Zhenghui Zhang; Chun-Yu Yip; William Grissom; Douglas C Noll; Fernando E Boada; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2007-05       Impact factor: 4.668

8.  Joint design of spoke trajectories and RF pulses for parallel excitation.

Authors:  Chao Ma; Dan Xu; Kevin F King; Zhi-Pei Liang
Journal:  Magn Reson Med       Date:  2010-11-05       Impact factor: 4.668

9.  Introduction to: A k-space analysis of small-tip-angle excitation.

Authors:  John M Pauly; Dwight G Nishimura; Albert Macovski
Journal:  J Magn Reson       Date:  2011-09-03       Impact factor: 2.229

10.  High-flip-angle slice-selective parallel RF transmission with 8 channels at 7 T.

Authors:  Kawin Setsompop; Vijayanand Alagappan; Adam C Zelinski; Andreas Potthast; Ulrich Fontius; Franz Hebrank; Franz Schmitt; Lawrence L Wald; Elfar Adalsteinsson
Journal:  J Magn Reson       Date:  2008-08-30       Impact factor: 2.229

View more
  9 in total

1.  Image homogenization using pre-emphasis method for high field MRI.

Authors:  Ye Li; Chunsheng Wang; Baiying Yu; Daniel Vigneron; Wei Chen; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2013-08

2.  Hepatic fat assessment using advanced Magnetic Resonance Imaging.

Authors:  Yong Pang; Baiying Yu; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2012-09

3.  Quadrature transmit array design using single-feed circularly polarized patch antenna for parallel transmission in MR imaging.

Authors:  Yong Pang; Baiying Yu; Daniel B Vigneron; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2014-02

4.  Design and numerical evaluation of a volume coil array for parallel MR imaging at ultrahigh fields.

Authors:  Yong Pang; Ernest W H Wong; Baiying Yu; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2014-02

5.  Sparse parallel transmission on randomly perturbed spiral k-space trajectory.

Authors:  Yong Pang; Xiaohua Jiang; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2014-04

6.  Comparison of RF body coils for MRI at 3  T: a simulation study using parallel transmission on various anatomical targets.

Authors:  Xiaoping Wu; Xiaotong Zhang; Jinfeng Tian; Sebastian Schmitter; Brian Hanna; John Strupp; Josef Pfeuffer; Michael Hamm; Dingxin Wang; Juergen Nistler; Bin He; Thomas J Vaughan; Kamil Ugurbil; Pierre-Francois Van de Moortele
Journal:  NMR Biomed       Date:  2015-08-30       Impact factor: 4.044

7.  Parallel Excitation in Ultrahigh Field Human MR Imaging and Multi-Channel Transmit System.

Authors:  Xiaoliang Zhang; Yong Pang
Journal:  OMICS J Radiol       Date:  2012-05

8.  Multi-reception strategy with improved SNR for multichannel MR imaging.

Authors:  Bing Wu; Ye Li; Chunsheng Wang; Daniel B Vigneron; Xiaoliang Zhang
Journal:  PLoS One       Date:  2012-08-03       Impact factor: 3.240

9.  Planar quadrature RF transceiver design using common-mode differential-mode (CMDM) transmission line method for 7T MR imaging.

Authors:  Ye Li; Baiying Yu; Yong Pang; Daniel B Vigneron; Xiaoliang Zhang
Journal:  PLoS One       Date:  2013-11-12       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.