Literature DB >> 23741535

Influence of file motion on cyclic fatigue of new nickel titanium instruments.

Alessio Giansiracusa Rubini1, Gianpaolo Sannino, Giancarlo Pongione, Luca Testarelli, Dina Al Sudani, Jeeraphat Jantarat, Massimo De Luca, Gianluca Gambarini.   

Abstract

AIM: The aim of the present study was to compare the resistance to cyclic fatigue of Hyflex® (Coltene-Whaledent, Allstatten, Switzerland) size 40 taper.04 nickel titanium instruments used in continuous rotation versus the use with a reciprocating motion. The null hypothesis was that different file motions had no influence on the lifetime of instruments subjected to a cyclic fatigue test.
METHODOLOGY: 24 Hyflex® size 40 taper.04 nickel titanium instruments were randomly divided in two groups (n=12 each), and submitted to a cyclic fatigue test. The first group (CR group) were used with a continuous rotation, while the second one (RCP group) with a reciprocating motion. The cyclic fatigue tests were performed by using a stainless steel block containing an artificial canal shaped with a 135° angle. All instruments were rotated or reciprocated until fracture occurred. The time to fracture was recorded visually with a 1/100 second chronometer. Data were recorded and statistically analysed.
RESULTS: Results indicated that instruments used with a reciprocating motion showed a significant increase in the meantime to failure when compared to those used in continuous rotation.
CONCLUSIONS: The null hypothesis was rejected. Results of the present study showed that reciprocating motion extended resistance to cyclic fatigue of the tested nickel titanium instruments, when compared to continuous rotation.

Entities:  

Keywords:  cyclic fatigue; instruments; nickel titanium

Year:  2013        PMID: 23741535      PMCID: PMC3671806          DOI: 10.11138/ads.0149

Source DB:  PubMed          Journal:  Ann Stomatol (Roma)        ISSN: 1824-0852


  17 in total

1.  Cyclic fatigue of nickel-titanium rotary instruments after clinical use with low- and high-torque endodontic motors.

Authors:  G Gambarini
Journal:  J Endod       Date:  2001-12       Impact factor: 4.171

2.  Cyclic fatigue testing of nickel-titanium endodontic instruments.

Authors:  J P Pruett; D J Clement; D L Carnes
Journal:  J Endod       Date:  1997-02       Impact factor: 4.171

3.  The effect of rotational speed and the curvature of root canals on the breakage of rotary endodontic instruments.

Authors:  Gabriela Zelada; Purificación Varela; Benjamín Martín; José G Bahíllo; Fernando Magán; Saem Ahn
Journal:  J Endod       Date:  2002-07       Impact factor: 4.171

4.  Lifespan of one nickel-titanium rotary file with reciprocating motion in curved root canals.

Authors:  Sung-Yeop You; Kwang-Shik Bae; Seung-Ho Baek; Kee-Yeon Kum; Won-Jun Shon; Woocheol Lee
Journal:  J Endod       Date:  2010-12       Impact factor: 4.171

5.  Accessing root canal systems: requirements and techniques.

Authors:  Ove A Peters
Journal:  Pract Proced Aesthet Dent       Date:  2006-06

6.  Separation incidence of protaper rotary instruments: a large cohort clinical evaluation.

Authors:  Susan Wolcott; James Wolcott; David Ishley; Wade Kennedy; Scott Johnson; Scott Minnich; John Meyers
Journal:  J Endod       Date:  2006-09-28       Impact factor: 4.171

7.  A retrospective clinical study of incidence of root canal instrument separation in an endodontics graduate program: a PennEndo database study.

Authors:  Mian K Iqbal; Meetu R Kohli; Jessica S Kim
Journal:  J Endod       Date:  2006-09-25       Impact factor: 4.171

8.  Modes of failure of ProTaper nickel-titanium rotary instruments after clinical use.

Authors:  Xi Wei; Junqi Ling; Jin Jiang; Xiangya Huang; Lu Liu
Journal:  J Endod       Date:  2007-01-08       Impact factor: 4.171

9.  Comparative study of torsional and bending properties for six models of nickel-titanium root canal instruments with different cross-sections.

Authors:  Xuejun Xu; M Eng; Yufeng Zheng; D Eng
Journal:  J Endod       Date:  2006-02-07       Impact factor: 4.171

10.  Bending properties of a new nickel-titanium alloy with a lower percent by weight of nickel.

Authors:  Luca Testarelli; Gianluca Plotino; Dina Al-Sudani; Valentina Vincenzi; Alessio Giansiracusa; Nicola M Grande; Gianluca Gambarini
Journal:  J Endod       Date:  2011-07-16       Impact factor: 4.171

View more
  1 in total

1.  Mechanical resistance of carbon and stainless steel hand instruments used in a reciprocating handpiece.

Authors:  Lucila Piasecki; Dina Al-Sudani; Alessio Giansiracusa Rubini; Giampaolo Sannino; Giampaolo Sonnino; Maurizio Bossù; Luca Testarelli; Roberto Di Giorgio; Ulisses Xavier da Silva-Neto; Christian Giampietro Brandão; Gianluca Gambarini
Journal:  Ann Stomatol (Roma)       Date:  2014-02-04
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.