Literature DB >> 29383604

Cyclic fatigue resistances of Hyflex EDM, WaveOne gold, Reciproc blue and 2shape NiTi rotary files in different artificial canals.

Taha Özyürek1, Mustafa Gündoğar2, Gülşah Uslu3, Koray Yılmaz4, Simone Staffoli5, Grande Nm6, Gianluca Plotino7, Antonella Polimeni5.   

Abstract

The aim of the present study was to compare the cyclic fatigue resistances of HyFlex EDM (HEDM), WaveOne Gold (WOG), Reciproc Blue (RB), and 2Shape (TS) NiTi systems having different metallurgic properties. HEDM, WOG, RB, and TS instruments were rotated in artificial canals which were made of stainless steel with an inner diameter of 1.5 mm, 45°, and 90° angles of curvatures and a radius of curvature of 5 mm until fracture occurred, and the time to fracture (TTF) was recorded in seconds. Also, number of cycles to fracture was calculated (NCF). Data were statistically analyzed using Kruskal-Wallis and t test. The statistical significance level was set at P < 0.05. When comparing the TTF of all the instruments tested in the artificial canal with 45° curvature, RB had statistically the highest cyclic fatigue resistance followed by HEDM and TS (P < 0.05), while the WOG showed the lowest cyclic fatigue resistance (P < 0.05). In artificial canal with 90° curvature, RB showed a significantly higher cyclic fatigue resistance than the other tested files (P < 0.05), while there was no significant difference among the TS, WOG and HEDM groups (P > 0.05). When the NCF values were taken into consideration, HEDM reported a significantly higher cyclic fatigue resistance than TS in both canal curvatures analyzed (P < 0.05). Within the limitations of the present study, RB NiTi files showed statistically higher cyclic fatigue resistance in artificial canals with 45° and 90° than the other NiTi files tested.

Entities:  

Keywords:  2Shape; Cyclic fatigue; HyFlex EDM; Reciproc blue; WaveOne gold

Mesh:

Substances:

Year:  2018        PMID: 29383604     DOI: 10.1007/s10266-018-0340-y

Source DB:  PubMed          Journal:  Odontology        ISSN: 1618-1247            Impact factor:   2.634


  25 in total

1.  Cyclic fatigue testing of nickel-titanium endodontic instruments.

Authors:  J P Pruett; D J Clement; D L Carnes
Journal:  J Endod       Date:  1997-02       Impact factor: 4.171

2.  Experimental evaluation on the influence of autoclave sterilization on the cyclic fatigue of new nickel-titanium rotary instruments.

Authors:  Gianluca Plotino; Alberto Costanzo; Nicola M Grande; Renata Petrovic; Luca Testarelli; Gianluca Gambarini
Journal:  J Endod       Date:  2011-11-21       Impact factor: 4.171

Review 3.  Current Assessment of Reciprocation in Endodontic Preparation: A Comprehensive Review-Part I: Historic Perspectives and Current Applications.

Authors:  Nicola Maria Grande; Hany Mohamed Aly Ahmed; Stephen Cohen; Frédéric Bukiet; Gianluca Plotino
Journal:  J Endod       Date:  2015-11       Impact factor: 4.171

4.  Bending properties of a new nickel-titanium alloy with a lower percent by weight of nickel.

Authors:  Luca Testarelli; Gianluca Plotino; Dina Al-Sudani; Valentina Vincenzi; Alessio Giansiracusa; Nicola M Grande; Gianluca Gambarini
Journal:  J Endod       Date:  2011-07-16       Impact factor: 4.171

5.  Influence of Temperature on Cyclic Fatigue Resistance of ProTaper Gold and ProTaper Universal Rotary Files.

Authors:  Gianluca Plotino; Nicola M Grande; Montse Mercadé Bellido; Luca Testarelli; Gianluca Gambarini
Journal:  J Endod       Date:  2016-12-15       Impact factor: 4.171

6.  Cyclic Fatigue Resistance of OneShape, HyFlex EDM, WaveOne Gold, and Reciproc Blue Nickel-titanium Instruments.

Authors:  Mustafa Gündoğar; Taha Özyürek
Journal:  J Endod       Date:  2017-05-17       Impact factor: 4.171

7.  Influence of continuous or reciprocating motion on cyclic fatigue resistance of 4 different nickel-titanium rotary instruments.

Authors:  Eugenio Pedullà; Nicola M Grande; Gianluca Plotino; Gianluca Gambarini; Ernesto Rapisarda
Journal:  J Endod       Date:  2012-12-01       Impact factor: 4.171

8.  Laboratory comparison of cyclic fatigue resistance of WaveOne Gold, Reciproc and WaveOne files in canals with a double curvature.

Authors:  H S Topçuoğlu; S Düzgün; A Aktı; G Topçuoğlu
Journal:  Int Endod J       Date:  2016-07-26       Impact factor: 5.264

9.  Effect of sodium hypochlorite and saline on cyclic fatigue resistance of WaveOne Gold and Reciproc reciprocating instruments.

Authors:  A M Elnaghy; S E Elsaka
Journal:  Int Endod J       Date:  2016-11-16       Impact factor: 5.264

Review 10.  A review of cyclic fatigue testing of nickel-titanium rotary instruments.

Authors:  Gianluca Plotino; Nicola M Grande; Massimo Cordaro; Luca Testarelli; Gianluca Gambarini
Journal:  J Endod       Date:  2009-09-01       Impact factor: 4.171

View more
  13 in total

1.  Comparison of the cyclic fatigue resistance of VDW.ROTATE, TruNatomy, 2Shape, and HyFlex CM nickel-titanium rotary files at body temperature.

Authors:  Mustafa Gündoğar; Gülşah Uslu; Taha Özyürek; Gianluca Plotino
Journal:  Restor Dent Endod       Date:  2020-06-22

2.  Postendodontic pain in asymptomatic necrotic teeth prepared with different rotary instrumentation techniques.

Authors:  Talal Al-Nahlawi; Ahmad Alabdullah; Alaa Othman; Raghad Sukkar; Mazen Doumani
Journal:  J Family Med Prim Care       Date:  2020-07-30

3.  Influence of different motions on the cyclic fatigue resistance of Reciproc and Reciproc Blue endodontic instruments.

Authors:  Marco Serafin; Matteo De Biasi; Vittorio Franco; Luigi Generali; Daniele Angerame
Journal:  J Conserv Dent       Date:  2020-08-04

4.  Differences in cyclic fatigue lifespan between two different heat treated NiTi endodontic rotary instruments: WaveOne Gold vs EdgeOne Fire.

Authors:  Gianluca Gambarini; Massimo Galli; Dario Di Nardo; Marco Seracchiani; Orlando Donfrancesco; Luca Testarelli
Journal:  J Clin Exp Dent       Date:  2019-07-01

Review 5.  Nickel-Titanium Rotary File Systems: What's New?

Authors:  Sadia Tabassum; Kamil Zafar; Fahad Umer
Journal:  Eur Endod J       Date:  2019-10-18

6.  Bending resistance and cyclic fatigue resistance of WaveOne Gold, Reciproc Blue, and HyFlex EDM instruments.

Authors:  Soram Oh; Kee-Yeon Kum; Hyun-Jung Kim; Su-Young Moon; Hyeon-Cheol Kim; Antonis Chaniotis; Hiran Perinpanayagam; Eugenio Pedullá; Seok Woo Chang
Journal:  J Dent Sci       Date:  2019-12-30       Impact factor: 2.080

Review 7.  Evolution and development: engine-driven endodontic rotary nickel-titanium instruments.

Authors:  Yuhong Liang; Lin Yue
Journal:  Int J Oral Sci       Date:  2022-02-18       Impact factor: 24.897

8.  Shaping ability of 2Shape and NeoNiTi rotary instruments in preparation of curved canals using micro-computed tomography.

Authors:  Ibrahim Faisal; Rajab Saif; Mona Alsulaiman; Zuhair S Natto
Journal:  BMC Oral Health       Date:  2021-11-19       Impact factor: 2.757

9.  Effect of number of uses and sterilization on the instrumented area and resistance of reciprocating instruments.

Authors:  Victor de Ornelas Peraça; Samantha Rodrigues Xavier; Fabio de Almeida Gomes; Luciane Geanini Pena Dos Santos; Erick Miranda Souza; Fernanda Geraldo Pappen
Journal:  Restor Dent Endod       Date:  2021-04-29

10.  Comparison of the ability of Reciproc and Reciproc Blue instruments to reach the full working length with or without glide path preparation.

Authors:  Mehmet Adıguzel; Pelin Tufenkci
Journal:  Restor Dent Endod       Date:  2018-11-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.