Literature DB >> 23386933

Flexibility and resistance to cyclic fatigue of endodontic instruments made with different nickel-titanium alloys: a comparative test.

Giancarlo Pongione1, Giorgio Pompa, Valerio Milana, Stefano Di Carlo, Alessio Giansiracusa, Emanuele Nicolini, Francesca De Angelis.   

Abstract

AIM: A new manufacturing method aiming at to producing more flexible and resistant NiTi endodontic instruments has been recently developed (Hyflex, produced with CM wire). The purpose of the study was to determine whether this new manufacturing method produces NiTi instruments (Hyflex) of superior flexibility and/or superior resistance to cyclic fatigue, when compared with instruments produced by a traditional manufacturing process or thermally treated NiTi alloy (M-wire).
MATERIALS AND METHODS: Twelve .06 size 25 Hyflex instruments (Coltene, Allstatten, Switzerland), and twelve 06.25 Vortex instruments (Dentsply-Tulsa, OK, USA) and twelve 06.25 Endosequence instruments (Brasseler, Savannah, GA, USA) were initially evaluated for stiffness on bending, followed by a cyclic fatigue test. For the stiffness test test procedures strictly followed ISO 3630-1, and bending moment was measured when the instrument attained a 45 degrees bend. The cyclic fatigue test was performed in a customized artificial stainless steel canal (60° degree curvature with 5 mm radius). Instruments were rotated at 300 rpm until fracture. All data obtained were recorded and statistically analyzed using an ANOVA test.
RESULTS: Statistical analysis of data showed that bending moments were significantly greater (P < .05) for Vortex and EndoSequence instruments (mean values 59.06 g/cm and 48,98 g/cm respectively), compared to the Hyflex instruments (mean value 35.60 g/cm). For the cyclic fatigue test Hyflex and Vortex were significantly more resistant than EndoSequence instruments (P < .05).
CONCLUSIONS: Results of the present study demonstrate the ability of the new CM-wire manufacturing process to produce NiTi rotary instruments more flexible and more resistant to cyclic fatigue than instruments produced by a traditional manufacturing process or a thermally treated NiTi alloy (M-wire).

Entities:  

Keywords:  NiTi alloy; cyclic fatigue test; resistance of endodontic instruments; rotary instruments

Year:  2012        PMID: 23386933      PMCID: PMC3555470     

Source DB:  PubMed          Journal:  Ann Stomatol (Roma)        ISSN: 1824-0852


  20 in total

1.  A comparison of stainless steel and nickel-titanium H-type instruments of identical design: torsional and bending tests.

Authors:  R B Kazemi; E Stenman; L S Spångberg
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2000-10

2.  Cyclic fatigue of nickel-titanium rotary instruments after clinical use with low- and high-torque endodontic motors.

Authors:  G Gambarini
Journal:  J Endod       Date:  2001-12       Impact factor: 4.171

3.  Cyclic fatigue of ProFile rotary instruments after prolonged clinical use.

Authors:  G Gambarini
Journal:  Int Endod J       Date:  2001-07       Impact factor: 5.264

Review 4.  Rotary NiTi instrument fracture and its consequences.

Authors:  Peter Parashos; Harold H Messer
Journal:  J Endod       Date:  2006-11       Impact factor: 4.171

5.  A retrospective clinical study of incidence of root canal instrument separation in an endodontics graduate program: a PennEndo database study.

Authors:  Mian K Iqbal; Meetu R Kohli; Jessica S Kim
Journal:  J Endod       Date:  2006-09-25       Impact factor: 4.171

6.  Comparative study of torsional and bending properties for six models of nickel-titanium root canal instruments with different cross-sections.

Authors:  Xuejun Xu; M Eng; Yufeng Zheng; D Eng
Journal:  J Endod       Date:  2006-02-07       Impact factor: 4.171

7.  Measurement of the trajectory of different NiTi rotary instruments in an artificial canal specifically designed for cyclic fatigue tests.

Authors:  Gianluca Plotino; Nicola M Grande; Massimo Cordaro; Luca Testarelli; Gianluca Gambarini
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2009-09

8.  Mechanical properties of a new and improved nickel-titanium alloy for endodontic use: an evaluation of file flexibility.

Authors:  Gianluca Gambarini; Roberto Gerosa; Massimo De Luca; Manish Garala; Luca Testarelli
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2008-04-16

9.  An initial investigation of the bending and torsional properties of Nitinol root canal files.

Authors:  H M Walia; W A Brantley; H Gerstein
Journal:  J Endod       Date:  1988-07       Impact factor: 4.171

10.  Quantitative and qualitative elemental analysis of different nickel-titanium rotary instruments by using scanning electron microscopy and energy dispersive spectroscopy.

Authors:  Hani F Ounsi; Thakib Al-Shalan; Ziad Salameh; Simone Grandini; Marco Ferrari
Journal:  J Endod       Date:  2008-01       Impact factor: 4.171

View more
  11 in total

1.  [Construction and mechanical analysis of finite element model for bending property of controlled memory wire nickel-titanium rotary file].

Authors:  H Y Fu; F F Wang; X M Hou
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2019-02-18

2.  Comparison of the cyclic fatigue resistance of One Curve, F6 Skytaper, Protaper Next, and Hyflex CM endodontic files.

Authors:  Charlotte Gouédard; Laurent Pino; Reza Arbab-Chirani; Shabnam Arbab-Chirani; Valérie Chevalier
Journal:  Restor Dent Endod       Date:  2022-03-04

3.  Microstructure of cryogenically treated martensitic shape memory nickel-titanium alloy.

Authors:  Thilla Sekar Vinothkumar; Deivanayagam Kandaswamy; Gopalakrishnan Prabhakaran; Arunachalam Rajadurai
Journal:  J Conserv Dent       Date:  2015 Jul-Aug

4.  Influence of motion pattern on apical transportation and centering ability of WaveOne single-file technique in curved root canals.

Authors:  Mandana Naseri; Payam Paymanpour; Ali Kangarloo; Sahar Haddadpur; Omid Dianat; Mohammad Ali Ketabi
Journal:  Dent Res J (Isfahan)       Date:  2016 Jan-Feb

5.  Shaping ability of reciprocating motion of WaveOne and HyFlex in moderate to severe curved canals: A comparative study with cone beam computed tomography.

Authors:  Gurram Samuel Simpsy; Girija S Sajjan; Padmaja Mudunuri; Jyothi Chittem; Nalam N V D Prasanthi; Pankaj Balaga
Journal:  J Conserv Dent       Date:  2016 Nov-Dec

6.  In vitro comparison of the cyclic fatigue resistance of HyFlex EDM, One G, and ProGlider nickel titanium glide path instruments in single and double curvature canals.

Authors:  Koray Yılmaz; Gülşah Uslu; Taha Özyürek
Journal:  Restor Dent Endod       Date:  2017-10-30

7.  Effects of Reciproc, ProTaper Next and WaveOne Gold on Root Canal Walls: A Stereomicroscope Analysis.

Authors:  Marcely Cassimiro; Kaline Romeiro; Luciana Gominho; Andressa de Almeida; Lívia Silva; Diana Albuquerque
Journal:  Iran Endod J       Date:  2018

8.  Role of the Flat-Designed Surface in Improving the Cyclic Fatigue Resistance of Endodontic NiTi Rotary Instruments.

Authors:  Gianluca Gambarini; Gabriele Miccoli; Marco Seracchiani; Tatyana Khrenova; Orlando Donfrancesco; Maurilio D'Angelo; Massimo Galli; Dario Di Nardo; Luca Testarelli
Journal:  Materials (Basel)       Date:  2019-08-08       Impact factor: 3.623

9.  Comparison of canal transportation and centering ability of Twisted Files, HyFlex controlled memory, and Wave One using computed tomography scan: An in vitro study.

Authors:  Abhinav Kishore; Anuraag Gurtu; Rashmi Bansal; Anurag Singhal; Sumit Mohan; Anmol Mehrotra
Journal:  J Conserv Dent       Date:  2017 May-Jun

10.  Effect of Deep Cryogenic Treatment on Cyclic Fatigue of Endodontic Rotary Nickel Titanium Instruments.

Authors:  Mohammad Yazdizadeh; Masoumeh Skini; Seyyed Mohsen Hoseini Goosheh; Mansour Jafarzadeh; Milad Shamohammadi; Vahid Rakhshan
Journal:  Iran Endod J       Date:  2017
View more