Literature DB >> 31891973

In Vivo Evaluation of Operative Torque Generated by Two Nickel-Titanium Rotary Instruments during Root Canal Preparation.

Gianluca Gambarini1, Massimo Galli1, Marco Seracchiani1, Dario Di Nardo1, Marco A Versiani2, Lucila Piasecki3, Luca Testarelli1.   

Abstract

OBJECTIVES: This in vivo study evaluated the operative torque and preparation time of ProTaper NEXT (Dentsply Maillefer; Ballaigues, Switzerland) and EdgeFile X7 (EdgeEndo; Albuquerque, New Mexico, United States) rotary systems during root canal preparation of maxillary premolars.
MATERIALS AND METHODS: Ten double-rooted maxillary premolars with independent canals were selected. Each canal in each tooth was prepared with one of the rotary systems (n = 10), ProTaper NEXT or EdgeFile X7. The instruments were rotated at 300 rpm with maximum torque set at 2 N.cm using an electric motor (KaVo; Biberach, Germany) that automatically recorded torque values at every 1/10th of a second (ds). STATISTICAL ANALYSIS: Operative torque (N.cm) and preparation time (s) of the first shaping instrument (size 17/.04) of both rotary systems were recorded and statistically compared using the Mann-Whiney U test with a significance level set at 5%.
RESULTS: No instrument exhibited flute deformation or underwent intracanal failure. No differences were found between the instruments regarding the maximum (peak) torque values (p > 0.05). EdgeFile X7 17/.04 required significantly less preparation time (3.75 seconds interquartile range [IQR]: 3.2-9.0) than ProTaper NEXT X1 (15.45 seconds IQR: 8.35-21.1) (p < 0.05). The median operative torque values of ProTaper NEXT X1 (0.26 N.cm; IQR: 0.18-0.49) were significantly higher compared with EdgeFile X7 17/.04 (0.09 N.cm; IQR: 0.05-0.17) (p < 0.05).
CONCLUSIONS: Although no difference was found between the median peak torque values of ProTaper NEXT X1 and EdgeFile X7 17/.04 instruments, the operative torque and instrumentation time results were impacted by their different designs and alloys during clinical preparation of root canals. Dental Investigation Society.

Entities:  

Year:  2019        PMID: 31891973      PMCID: PMC6938430          DOI: 10.1055/s-0039-1698369

Source DB:  PubMed          Journal:  Eur J Dent


  33 in total

1.  Cyclic fatigue of ProFile rotary instruments after clinical use.

Authors:  G M Yared; F E Bou Dagher; P Machtou
Journal:  Int Endod J       Date:  2000-05       Impact factor: 5.264

2.  The effect of brushing motion on the cyclic fatigue of rotary nickel titanium instruments.

Authors:  Gianluca Gambarini; Eugenio Tucci; Rossella Bedini; Raffaella Pecci; Massimo Galli; Valerio Milana; Massimo De Luca; Luca Testarelli
Journal:  Ann Ist Super Sanita       Date:  2010       Impact factor: 1.663

3.  An initial investigation on torsional properties of nickel-titanium instruments produced with a new manufacturing method.

Authors:  Gianluca Gambarini; Giorgio Pompa; Stefano Di Carlo; Massimo De Luca; Luca Testarelli
Journal:  Aust Endod J       Date:  2009-08       Impact factor: 1.659

4.  Bending properties of a new nickel-titanium alloy with a lower percent by weight of nickel.

Authors:  Luca Testarelli; Gianluca Plotino; Dina Al-Sudani; Valentina Vincenzi; Alessio Giansiracusa; Nicola M Grande; Gianluca Gambarini
Journal:  J Endod       Date:  2011-07-16       Impact factor: 4.171

5.  Instrument separation analysis of multi-used ProTaper Universal rotary system during root canal therapy.

Authors:  Jintao Wu; Gang Lei; Ming Yan; Yan Yu; Jinhua Yu; Guangdong Zhang
Journal:  J Endod       Date:  2011-04-02       Impact factor: 4.171

6.  Influence of Temperature on Cyclic Fatigue Resistance of ProTaper Gold and ProTaper Universal Rotary Files.

Authors:  Gianluca Plotino; Nicola M Grande; Montse Mercadé Bellido; Luca Testarelli; Gianluca Gambarini
Journal:  J Endod       Date:  2016-12-15       Impact factor: 4.171

7.  A comparison of canal preparations in straight and curved root canals.

Authors:  S W Schneider
Journal:  Oral Surg Oral Med Oral Pathol       Date:  1971-08

8.  Effect of the Glide Path Establishment on the Torque Generation to the Files during Instrumentation: An In Vitro Measurement.

Authors:  Sang Won Kwak; Jung-Hong Ha; Gary Shun-Pan Cheung; Hyeon-Cheol Kim; Sung Kyo Kim
Journal:  J Endod       Date:  2017-12-02       Impact factor: 4.171

9.  Root surface strain during canal shaping and its influence on apical microcrack development: a preliminary investigation.

Authors:  A Jamleh; T Komabayashi; A Ebihara; M Nassar; S Watanabe; T Yoshioka; K Miyara; H Suda
Journal:  Int Endod J       Date:  2014-12-08       Impact factor: 5.264

10.  Location of contact areas on rotary Profile instruments in relationship to the forces developed during mechanical preparation on extracted teeth.

Authors:  J Y Blum; P Machtou; J P Micallef
Journal:  Int Endod J       Date:  1999-03       Impact factor: 5.264

View more
  1 in total

1.  Comparative Evaluation of Fracture Resistance of Endodontically Treated Bicuspids Instrumented With Hand Files, TruNatomy, ProTaper Next, ProTaper Gold, and WaveOne - An In vitro Study.

Authors:  Sulfia Nassar; Harish Kumar Shetty; Prathap M S Nair; Sree Gowri; K Jayaprakash
Journal:  J Pharm Bioallied Sci       Date:  2022-07-13
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.