Literature DB >> 21842580

Subharmonic contrast microbubble signals for noninvasive pressure estimation under static and dynamic flow conditions.

Valgerdur G Halldorsdottir1, Jaydev K Dave, Lauren M Leodore, John R Eisenbrey, Suhyun Park, Anne L Hall, Kai Thomenius, Flemming Forsberg.   

Abstract

Our group has proposed the concept of subharmonic aided pressure estimation (SHAPE) utilizing microbubble-based ultrasound contrast agent signals for the noninvasive estimation of hydrostatic blood pressures. An experimental system for in vitro SHAPE was constructed based on two single-element transducers assembled confocally at a 60 degree angle to each other. Changes in the first, second and subharmonic amplitudes of five different ultrasound contrast agents were measured in vitro at static hydrostatic pressures from 0-186 mmHg, acoustic pressures from 0.35-0.60 MPa peak-to-peak and frequencies of 2.5-6.6 MHz. The most sensitive agent and optimal parameters for SHAPE were determined using linear regression analysis and implemented on a Logiq 9 scanner (GE Healthcare, Milwaukee, WI). This implementation of SHAPE was then tested under dynamic-flow conditions and compared to pressure-catheter measurements. Over the pressure range studied, the first and second harmonic amplitudes reduced approximately 2 dB for all contrast agents. Over the same pressure range, the subharmonic amplitudes decreased by 9-14 dB and excellent linear regressions were achieved with the hydrostatic pressure variations (r = 0.98, p < 0.001). Optimal sensitivity was achieved at a transmit frequency of 2.5 MHz and acoustic pressure of 0.35 MPa using Sonazoid (GE Healthcare, Oslo, Norway). A Logiq 9 scanner was modified to implement SHAPE on a convex transducer with a frequency range from 1.5-4.5 MHz and acoustic pressures from 0-3.34 MPa. Results matched the pressure catheter (r2 = 0.87). In conclusion, subharmonic contrast signals are a good indicator of hydrostatic pressure. Out of the five ultrasound contrast agents tested, Sonazoid was the most sensitive for subharmonic pressure estimation. Real-time SHAPE has been implemented on a commercial scanner and offers the possibility of allowing pressures in the heart and elsewhere to be obtained noninvasively.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21842580      PMCID: PMC7158747          DOI: 10.1177/016173461103300301

Source DB:  PubMed          Journal:  Ultrason Imaging        ISSN: 0161-7346            Impact factor:   1.578


  24 in total

1.  Subharmonic imaging of contrast agents.

Authors:  F Forsberg; W T Shi; B B Goldberg
Journal:  Ultrasonics       Date:  2000-03       Impact factor: 2.890

2.  Noninvasive measurement of the hydrostatic pressure in a fluid-filled cavity based on the disappearance time of micrometer-sized free gas bubbles.

Authors:  A Bouakaz; P J Frinking; N de Jong; N Bom
Journal:  Ultrasound Med Biol       Date:  1999-11       Impact factor: 2.998

3.  Noninvasive blood pressure measurement in mice using pulsed Doppler ultrasound.

Authors:  Anilkumar K Reddy; George E Taffet; Sridhar Madala; Lloyd H Michael; Mark L Entman; Craig J Hartley
Journal:  Ultrasound Med Biol       Date:  2003-03       Impact factor: 2.998

4.  Subharmonic scattering of phospholipid-shell microbubbles at low acoustic pressure amplitudes.

Authors:  Peter J A Frinking; Jean Brochot; Marcel Arditi
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2010-08       Impact factor: 2.725

5.  On the relationship between encapsulated ultrasound contrast agent and pressure.

Authors:  Dan Adam; Michal Sapunar; Elina Burla
Journal:  Ultrasound Med Biol       Date:  2005-05       Impact factor: 2.998

6.  Breast lesions: imaging with contrast-enhanced subharmonic US--initial experience.

Authors:  Flemming Forsberg; Catherine W Piccoli; Daniel A Merton; Juan J Palazzo; Anne L Hall
Journal:  Radiology       Date:  2007-08-09       Impact factor: 11.105

7.  Modeling subharmonic response from contrast microbubbles as a function of ambient static pressure.

Authors:  Amit Katiyar; Kausik Sarkar; Flemming Forsberg
Journal:  J Acoust Soc Am       Date:  2011-04       Impact factor: 1.840

8.  Advantages of subharmonic over second harmonic backscatter for contrast-to-tissue echo enhancement.

Authors:  P M Shankar; P Dala Krishna; V L Newhouse
Journal:  Ultrasound Med Biol       Date:  1998-03       Impact factor: 2.998

9.  Noninvasive assessment of pressure gradients across iliac artery stenoses: duplex and catheter correlative study.

Authors:  A L Strauss; F J Roth; H Rieger
Journal:  J Ultrasound Med       Date:  1993-01       Impact factor: 2.153

10.  Simultaneous grayscale and subharmonic ultrasound imaging on a modified commercial scanner.

Authors:  J R Eisenbrey; J K Dave; V G Halldorsdottir; D A Merton; P Machado; J B Liu; C Miller; J M Gonzalez; S Park; S Dianis; C L Chalek; K E Thomenius; D B Brown; V Navarro; F Forsberg
Journal:  Ultrasonics       Date:  2011-05-10       Impact factor: 2.890

View more
  20 in total

1.  Subharmonic microbubble emissions for noninvasively tracking right ventricular pressures.

Authors:  Jaydev K Dave; Valgerdur G Halldorsdottir; John R Eisenbrey; Joel S Raichlen; Ji-Bin Liu; Maureen E McDonald; Kris Dickie; Shumin Wang; Corina Leung; Flemming Forsberg
Journal:  Am J Physiol Heart Circ Physiol       Date:  2012-05-04       Impact factor: 4.733

2.  Subharmonic aided pressure estimation for monitoring interstitial fluid pressure in tumours--in vitro and in vivo proof of concept.

Authors:  V G Halldorsdottir; J K Dave; J R Eisenbrey; P Machado; H Zhao; J B Liu; D A Merton; F Forsberg
Journal:  Ultrasonics       Date:  2014-05-06       Impact factor: 2.890

3.  Three-Dimensional Subharmonic Aided Pressure Estimation for Assessing Arterial Plaques in a Rabbit Model.

Authors:  Kibo Nam; Ji-Bin Liu; John R Eisenbrey; Maria Stanczak; Priscilla Machado; Jingzhi Li; Zhaojun Li; Ying Wei; Flemming Forsberg
Journal:  J Ultrasound Med       Date:  2018-12-17       Impact factor: 2.153

4.  Non-Invasive Intra-cardiac Pressure Measurements Using Subharmonic-Aided Pressure Estimation: Proof of Concept in Humans.

Authors:  Jaydev K Dave; Sushmita V Kulkarni; Purva P Pangaonkar; Maria Stanczak; Maureen E McDonald; Ira S Cohen; Praveen Mehrotra; Michael P Savage; Paul Walinsky; Nicholas J Ruggiero; David L Fischman; David Ogilby; Carolyn VanWhy; Matthew Lombardi; Flemming Forsberg
Journal:  Ultrasound Med Biol       Date:  2017-08-12       Impact factor: 2.998

5.  A Noninvasive Ultrasound Based Technique to Identify Treatment Responders in Patients with Portal Hypertension.

Authors:  Ipshita Gupta; Jonathan M Fenkel; John R Eisenbrey; Priscilla Machado; Maria Stanczak; Corinne E Wessner; Colette M Shaw; Cynthia Miller; Michael C Soulen; Kirk Wallace; Flemming Forsberg
Journal:  Acad Radiol       Date:  2020-12-16       Impact factor: 3.173

6.  The delayed onset of subharmonic and ultraharmonic emissions from a phospholipid-shelled microbubble contrast agent.

Authors:  Himanshu Shekhar; Ivy Awuor; Keri Thomas; Joshua J Rychak; Marvin M Doyley
Journal:  Ultrasound Med Biol       Date:  2014-04       Impact factor: 2.998

7.  Subharmonic-Aided Pressure Estimation for Monitoring Interstitial Fluid Pressure in Tumors: Calibration and Treatment with Paclitaxel in Breast Cancer Xenografts.

Authors:  Valgerdur G Halldorsdottir; Jaydev K Dave; Andrew Marshall; Anya I Forsberg; Traci B Fox; John R Eisenbrey; Priscilla Machado; Ji-Bin Liu; Daniel A Merton; Flemming Forsberg
Journal:  Ultrasound Med Biol       Date:  2017-04-19       Impact factor: 2.998

8.  Effect of Pulse Shaping on Subharmonic Aided Pressure Estimation In Vitro and In Vivo.

Authors:  Ipshita Gupta; John Eisenbrey; Maria Stanczak; Anush Sridharan; Jaydev K Dave; Ji-Bin Liu; Christopher Hazard; Xinghua Wang; Ping Wang; Huiwen Li; Kirk Wallace; Flemming Forsberg
Journal:  J Ultrasound Med       Date:  2016-12-10       Impact factor: 2.153

9.  Chronic liver disease: noninvasive subharmonic aided pressure estimation of hepatic venous pressure gradient.

Authors:  John R Eisenbrey; Jaydev K Dave; Valgerdur G Halldorsdottir; Daniel A Merton; Cynthia Miller; José M Gonzalez; Priscilla Machado; Suhyun Park; Scott Dianis; Carl L Chalek; Christopher E Kim; Jeffrey P Baliff; Kai E Thomenius; Daniel B Brown; Victor Navarro; Flemming Forsberg
Journal:  Radiology       Date:  2013-03-22       Impact factor: 11.105

10.  On the implementation of an automated acoustic output optimization algorithm for subharmonic aided pressure estimation.

Authors:  J K Dave; V G Halldorsdottir; J R Eisenbrey; D A Merton; J B Liu; P Machado; H Zhao; S Park; S Dianis; C L Chalek; K E Thomenius; D B Brown; F Forsberg
Journal:  Ultrasonics       Date:  2013-01-02       Impact factor: 2.890

View more