Literature DB >> 20704062

Subharmonic scattering of phospholipid-shell microbubbles at low acoustic pressure amplitudes.

Peter J A Frinking1, Jean Brochot, Marcel Arditi.   

Abstract

Subharmonic scattering of phospholipid-shell microbubbles excited at relatively low acoustic pressure amplitudes (<30 kPa) has been associated with echo responses from compression-only bubbles having initial surface tension values close to zero. In this work, the relation between sbharmonics and compression-only behavior of phospholipid-shell microbubbles was investigated, experimentally and by simulation, as a function of the initial surface tension by applying ambient overpressures of 0 and 180 mmHg. The microbubbles were excited using a 64-cycle transmit burst with a center frequency of 4 MHz and peak-negative pressure amplitudes ranging from 20 of 150 kPa. In these conditions, an increase in subharmonic response of 28.9 dB (P < 0.05) was measured at 50 kPa after applying an overpressure of 180 mmHg. Simulations using the Marmottant model, taking into account the effect of ambient overpressure on bubble size and initial surface tension, confirmed the relation between subharmonics observed in the pressure-time curves and compression-only behavior observed in the radius-time curves. The trend of an increase in subharmonic response as a function of ambient overpressure, i.e., as a function of the initial surface tension, was predicted by the model. Subharmonics present in the echo responses of phospholipid-shell microbubbles excited at low acoustic pressure amplitudes are indeed related to the echo responses from compression-only bubbles. The increase in subharmonics as a function of ambient overpressure may be exploited for improving methods for noninvasive pressure measurement in heart cavities or big vessels in the human body.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20704062     DOI: 10.1109/tuffc.2010.1614

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  17 in total

1.  Excitation threshold for subharmonic generation from contrast microbubbles.

Authors:  Amit Katiyar; Kausik Sarkar
Journal:  J Acoust Soc Am       Date:  2011-11       Impact factor: 1.840

2.  Subharmonic microbubble emissions for noninvasively tracking right ventricular pressures.

Authors:  Jaydev K Dave; Valgerdur G Halldorsdottir; John R Eisenbrey; Joel S Raichlen; Ji-Bin Liu; Maureen E McDonald; Kris Dickie; Shumin Wang; Corina Leung; Flemming Forsberg
Journal:  Am J Physiol Heart Circ Physiol       Date:  2012-05-04       Impact factor: 4.733

3.  Subharmonic aided pressure estimation for monitoring interstitial fluid pressure in tumours--in vitro and in vivo proof of concept.

Authors:  V G Halldorsdottir; J K Dave; J R Eisenbrey; P Machado; H Zhao; J B Liu; D A Merton; F Forsberg
Journal:  Ultrasonics       Date:  2014-05-06       Impact factor: 2.890

4.  Modeling subharmonic response from contrast microbubbles as a function of ambient static pressure.

Authors:  Amit Katiyar; Kausik Sarkar; Flemming Forsberg
Journal:  J Acoust Soc Am       Date:  2011-04       Impact factor: 1.840

5.  Effects of encapsulation damping on the excitation threshold for subharmonic generation from contrast microbubbles.

Authors:  Amit Katiyar; Kausik Sarkar
Journal:  J Acoust Soc Am       Date:  2012-11       Impact factor: 1.840

6.  The response of phospholipid-encapsulated microbubbles to chirp-coded excitation: implications for high-frequency nonlinear imaging.

Authors:  Himanshu Shekhar; Marvin M Doyley
Journal:  J Acoust Soc Am       Date:  2013-05       Impact factor: 1.840

7.  The delayed onset of subharmonic and ultraharmonic emissions from a phospholipid-shelled microbubble contrast agent.

Authors:  Himanshu Shekhar; Ivy Awuor; Keri Thomas; Joshua J Rychak; Marvin M Doyley
Journal:  Ultrasound Med Biol       Date:  2014-04       Impact factor: 2.998

8.  Chronic liver disease: noninvasive subharmonic aided pressure estimation of hepatic venous pressure gradient.

Authors:  John R Eisenbrey; Jaydev K Dave; Valgerdur G Halldorsdottir; Daniel A Merton; Cynthia Miller; José M Gonzalez; Priscilla Machado; Suhyun Park; Scott Dianis; Carl L Chalek; Christopher E Kim; Jeffrey P Baliff; Kai E Thomenius; Daniel B Brown; Victor Navarro; Flemming Forsberg
Journal:  Radiology       Date:  2013-03-22       Impact factor: 11.105

9.  On the implementation of an automated acoustic output optimization algorithm for subharmonic aided pressure estimation.

Authors:  J K Dave; V G Halldorsdottir; J R Eisenbrey; D A Merton; J B Liu; P Machado; H Zhao; S Park; S Dianis; C L Chalek; K E Thomenius; D B Brown; F Forsberg
Journal:  Ultrasonics       Date:  2013-01-02       Impact factor: 2.890

10.  Stability of echogenic liposomes as a blood pool ultrasound contrast agent in a physiologic flow phantom.

Authors:  Kirthi Radhakrishnan; Kevin J Haworth; Shao-Ling Huang; Melvin E Klegerman; David D McPherson; Christy K Holland
Journal:  Ultrasound Med Biol       Date:  2012-08-25       Impact factor: 2.998

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.