Noninvasive blood pressure measurement in mice using pulsed Doppler ultrasound.

Anilkumar K Reddy1, George E Taffet, Sridhar Madala, Lloyd H Michael, Mark L Entman, Craig J Hartley.   

Abstract

Existing tail-cuff pressure devices for mice use tail flow sensors that measure only systolic and mean pressure. We developed a method to obtain systolic and diastolic pressure in mice using a pulsed Doppler flow velocity sensor and a tail-cuff and validated the method against pressure signals obtained simultaneously from a fluid-filled catheter. The tail-cuff was pressurized to suprasystolic levels to completely occlude the tail artery and then released gradually. The pressure at which the tail flow reappeared was recorded as systolic and the pressure at which the tail flow became continuous was recorded as diastolic. Regression analysis of tail-cuff pressures over catheter pressures obtained from healthy mice (n = 16) showed a high degree of association (r(sys) = 0.95, r(dia) = 0.94, both at p < 0.001). Bland-Altman analysis showed good agreement between the two methods, with a mean difference of -13 ( +/- 12 SD) mmHg and 3 ( +/- 10 SD) mmHg in the systolic (58 to 250 mmHg) and diastolic (48 to 178 mmHg) pressure measurements, respectively. Bland-Altman plots of tail-cuff blood pressures of a second group of mice (n = 20) showed good agreement between repeated measurements obtained on the same day, but had higher variability between measurements made on different days.

Entities:  

Mesh:

Year:  2003        PMID: 12706189     DOI: 10.1016/s0301-5629(02)00746-9

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  9 in total

1.  Modeling subharmonic response from contrast microbubbles as a function of ambient static pressure.

Authors:  Amit Katiyar; Kausik Sarkar; Flemming Forsberg
Journal:  J Acoust Soc Am       Date:  2011-04       Impact factor: 1.840

2.  Instrument for fluorescence sensing of circulating cells with diffuse light in mice in vivo.

Authors:  Eric Zettergren; Dwayne Vickers; Judith Runnels; Shashi K Murthy; Charles P Lin; Mark Niedre
Journal:  J Biomed Opt       Date:  2012-03       Impact factor: 3.170

3.  Regulatable atrial natriuretic peptide gene therapy for hypertension.

Authors:  Kurt J Schillinger; Sophia Y Tsai; George E Taffet; Anilkumar K Reddy; Ali J Marian; Mark L Entman; Kazuhiro Oka; Lawrence Chan; Bert W O'Malley
Journal:  Proc Natl Acad Sci U S A       Date:  2005-09-14       Impact factor: 11.205

4.  Subharmonic contrast microbubble signals for noninvasive pressure estimation under static and dynamic flow conditions.

Authors:  Valgerdur G Halldorsdottir; Jaydev K Dave; Lauren M Leodore; John R Eisenbrey; Suhyun Park; Anne L Hall; Kai Thomenius; Flemming Forsberg
Journal:  Ultrason Imaging       Date:  2011-07       Impact factor: 1.578

5.  Multichannel pulsed Doppler signal processing for vascular measurements in mice.

Authors:  Anilkumar K Reddy; Sridhar Madala; Alan D Jones; Walter A Caro; John F Eberth; T Thuy Pham; George E Taffet; Craig J Hartley
Journal:  Ultrasound Med Biol       Date:  2009-10-24       Impact factor: 2.998

6.  Importance of pulsatility in hypertensive carotid artery growth and remodeling.

Authors:  John F Eberth; Vincent C Gresham; Anilkumar K Reddy; Natasa Popovic; Emily Wilson; Jay D Humphrey
Journal:  J Hypertens       Date:  2009-10       Impact factor: 4.844

7.  Evaluation of cerebrovascular impedance and wave reflection in mouse by ultrasound.

Authors:  Christopher K Macgowan; Sarah Joy Stoops; Yu-Qing Zhou; Lindsay S Cahill; John G Sled
Journal:  J Cereb Blood Flow Metab       Date:  2014-12-17       Impact factor: 6.200

8.  Sensory and Motor Conduction Velocity in Spontaneously Hypertensive Rats: Sex and Aging Investigation.

Authors:  Lucas B Fontanesi; Frederico S Fazan; Fernando J Dias; Maria Cristina L Schiavoni; Wilson Marques; Valéria Paula Sassoli Fazan
Journal:  Front Syst Neurosci       Date:  2019-11-01

9.  Bio-Impedance Sensor for Real-Time Artery Diameter Waveform Assessment.

Authors:  Mugeb Al-Harosh; Marat Yangirov; Dmitry Kolesnikov; Sergey Shchukin
Journal:  Sensors (Basel)       Date:  2021-12-17       Impact factor: 3.576

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.