Step and shoot coronary CT angiography using 256-slice CT: effect of heart rate and heart rate variability on image quality.

D Muenzel1, P B Noel, F Dorn, M Dobritz, E J Rummeny, A Huber.   

Abstract

OBJECTIVE: To evaluate the effect of heart rate variability (HRV) and heart rate (HR) on intra-image "motion" and inter-image "stairstep" artefacts in step-and-shoot coronary CT angiography (CCTA) using a wide detector CT scanner.
METHODS: 66 patients underwent step-and-shoot CCTA using 256-slice CT. Patients were divided into two groups (Group 1: HR <65 bpm, Group 2 ≥65bpm). Motion artefacts were quantified using a 5-point-scale. Stairstep artefacts were defined by measurements of misalignment. Image noise, contrast-to-noise-ratio (CNR), signal-to-noise-ratio (SNR), and radiation dose were assessed.
RESULTS: Mean HR was 66 ± 16.7 bpm (range: 45-125 bpm) and mean HRV was 10.7 ± 17.5 bpm. A significant correlation between HR and stairstep artefacts (r = 0.46, p < 0.001) and motion artefacts (r = 0.63, p < 0.001) was found. Group 2 showed significantly increased step artefacts with a mean misalignment of 1.4 mm compared to 0.4 mm in Group 1 (p < 0.001). There was no significant effect of HRV on stairstep artefacts (r = 0.15, p = 0.416) and motion artefacts (r = 0.13, p = 0.311). No significant differences in image noise, CNR, SNR, and radiation dose were seen.
CONCLUSIONS: Unlike CCTA using narrow CT detectors, HRV has no significant effect on motion and stairstep artefacts using a wide CT detector with high z-coverage. However, a higher HR still increases stairstep and motion artefacts.

Entities:  

Mesh:

Year:  2011        PMID: 21710267     DOI: 10.1007/s00330-011-2185-4

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  26 in total

1.  Image quality, motion artifacts, and reconstruction timing of 64-slice coronary computed tomography angiography with 0.33-second rotation speed.

Authors:  Bernd J Wintersperger; Konstantin Nikolaou; Franz von Ziegler; Thorsten Johnson; Carsten Rist; Alexander Leber; Thomas Flohr; Andreas Knez; Maximilian F Reiser; Christoph R Becker
Journal:  Invest Radiol       Date:  2006-05       Impact factor: 6.016

2.  A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association.

Authors:  W G Austen; J E Edwards; R L Frye; G G Gensini; V L Gott; L S Griffith; D C McGoon; M L Murphy; B B Roe
Journal:  Circulation       Date:  1975-04       Impact factor: 29.690

3.  Image quality and reconstruction intervals of dual-source CT coronary angiography: recommendations for ECG-pulsing windowing.

Authors:  Sebastian Leschka; Hans Scheffel; Lotus Desbiolles; Andre Plass; Oliver Gaemperli; Ines Valenta; Lars Husmann; Thomas G Flohr; Michele Genoni; Borut Marincek; Philipp A Kaufmann; Hatem Alkadhi
Journal:  Invest Radiol       Date:  2007-08       Impact factor: 6.016

4.  Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: improved image quality and reduced radiation dose.

Authors:  James P Earls; Elise L Berman; Bruce A Urban; Charlene A Curry; Judith L Lane; Robert S Jennings; Colin C McCulloch; Jiang Hsieh; John H Londt
Journal:  Radiology       Date:  2008-01-14       Impact factor: 11.105

5.  Low-dose CT coronary angiography using prospective ECG-triggering: impact of mean heart rate and heart rate variability on image quality.

Authors:  Bernhard A Herzog; Lars Husmann; Nina Burkhard; Ines Valenta; Oliver Gaemperli; Fuminari Tatsugami; Christophe A Wyss; Uif Landmesser; Philipp A Kaufmann
Journal:  Acad Radiol       Date:  2009-01       Impact factor: 3.173

Review 6.  Recent developments in wide-detector cardiac computed tomography.

Authors:  Sang Il Choi; Richard T George; Karl H Schuleri; Eun Ju Chun; Joao A C Lima; Albert C Lardo
Journal:  Int J Cardiovasc Imaging       Date:  2009-03-03       Impact factor: 2.357

7.  Robustness of end-systolic reconstructions in coronary dual-source CT angiography for high heart rate patients.

Authors:  Ghazal Adler; Laurent Meille; Adela Rohnean; Anne Sigal-Cinqualbre; André Capderou; Jean-François Paul
Journal:  Eur Radiol       Date:  2009-11-05       Impact factor: 5.315

Review 8.  CT coronary angiography: 256-slice and 320-detector row scanners.

Authors:  Edward M Hsiao; Frank J Rybicki; Michael Steigner
Journal:  Curr Cardiol Rep       Date:  2010-01       Impact factor: 2.931

9.  Body physique and heart rate variability determine the occurrence of stair-step artefacts in 64-slice CT coronary angiography with prospective ECG-triggering.

Authors:  Lars Husmann; Bernhard A Herzog; Nina Burkhard; Fuminari Tatsugami; Ines Valenta; Oliver Gaemperli; Christophe A Wyss; Ulf Landmesser; Philipp A Kaufmann
Journal:  Eur Radiol       Date:  2009-02-24       Impact factor: 5.315

10.  Diagnostic accuracy of 320-row multidetector computed tomography coronary angiography in the non-invasive evaluation of significant coronary artery disease.

Authors:  Fleur R de Graaf; Joanne D Schuijf; Joëlla E van Velzen; Lucia J Kroft; Albert de Roos; Johannes H C Reiber; Eric Boersma; Martin J Schalij; Fabrizio Spanó; J Wouter Jukema; Ernst E van der Wall; Jeroen J Bax
Journal:  Eur Heart J       Date:  2010-01-04       Impact factor: 29.983

View more
  17 in total

Review 1.  Image quality in coronary CT angiography: challenges and technical solutions.

Authors:  Olivier Ghekiere; Rodrigo Salgado; Nico Buls; Tim Leiner; Isabelle Mancini; Piet Vanhoenacker; Paul Dendale; Alain Nchimi
Journal:  Br J Radiol       Date:  2017-03-07       Impact factor: 3.039

2.  Radiation dose considerations by intra-individual Monte Carlo simulations in dual source spiral coronary computed tomography angiography with electrocardiogram-triggered tube current modulation and adaptive pitch.

Authors:  Matthias S May; Paul Deak; Axel Kuettner; Michael M Lell; Wolfgang Wuest; Michael Scharf; Andrea K Keller; Lothar Häberle; Stephan Achenbach; Martin Seltmann; Michael Uder; Willi A Kalender
Journal:  Eur Radiol       Date:  2011-10-09       Impact factor: 5.315

3.  Correlation between low tube voltage in dual source CT coronary artery imaging with image quality and radiation dose.

Authors:  Zi-Qiao Lei; Ping Han; Hai-Bo Xu; Jian-Ming Yu; Hong-Li Liu
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2014-08-19

4.  Image Quality of 256-Slice Computed Tomography for Coronary Angiography.

Authors:  Shu-Ping Chao; Jyh-Gang Leu; Wai-Yip Law; Chu-Jen Kuo; Kou-Gi Shyu
Journal:  Acta Cardiol Sin       Date:  2013-09       Impact factor: 2.672

5.  Effect of heart rate on the diagnostic accuracy of 256-slice computed tomography angiography in the detection of coronary artery stenosis: ROC curve analysis.

Authors:  Gang Wang; Yifen Wu; Zhentao Zhang; Xiaolin Zheng; Yulan Zhang; Manqiu Liang; Huanchu Yuan; Haiping Shen; Dewei Li
Journal:  Exp Ther Med       Date:  2016-03-11       Impact factor: 2.447

6.  The feasibility of halfcycle reconstruction in high heart rates in coronary CT angiography using 320-row CT.

Authors:  Nobuo Tomizawa; Kodai Yamamoto; Masaaki Akahane; Rumiko Torigoe; Shigeru Kiryu; Kuni Ohtomo
Journal:  Int J Cardiovasc Imaging       Date:  2012-11-10       Impact factor: 2.357

7.  Age-related differences in image quality of prospectively ECG-triggered axial and helical scans for coronary CT angiography.

Authors:  Makoto Takase; Shinichiro Fujimoto; Kazuhisa Takamura; Haruyo Yamashita; Kenji Uno; Shigeki Aoki
Journal:  Radiol Phys Technol       Date:  2016-03-16

8.  Second-generation motion correction algorithm improves diagnostic accuracy of single-beat coronary CT angiography in patients with increased heart rate.

Authors:  Junfu Liang; Ying Sun; Ziqing Ye; Yanchun Sun; Lei Xu; Zhen Zhou; Brian Thomsen; Jianying Li; Zhonghua Sun; Zhanming Fan
Journal:  Eur Radiol       Date:  2019-01-07       Impact factor: 5.315

9.  Influence of the motion correction algorithm on the quality and interpretability of images of single-source 64-detector coronary CT angiography among patients grouped by heart rate.

Authors:  Haruhiko Machida; Xiao-Zhu Lin; Rika Fukui; Yun Shen; Shigeru Suzuki; Isao Tanaka; Takuya Ishikawa; Etsuko Tate; Eiko Ueno
Journal:  Jpn J Radiol       Date:  2014-12-12       Impact factor: 2.374

10.  Reduction of cardiac motion artifact in step-and-shoot coronary CT angiography with third-generation as compared with second-generation dual-source CT scanners.

Authors:  Liang Jin; Ji'an Zhou; Yiyi Gao; Wei Zhao; Ming Li; Zhizhong Wang
Journal:  Diagn Interv Radiol       Date:  2021-07       Impact factor: 2.630