Second-generation motion correction algorithm improves diagnostic accuracy of single-beat coronary CT angiography in patients with increased heart rate.

Junfu Liang1,2, Ying Sun2, Ziqing Ye2, Yanchun Sun2, Lei Xu3, Zhen Zhou1, Brian Thomsen4, Jianying Li5, Zhonghua Sun6, Zhanming Fan1.   

Abstract

OBJECTIVE: To assess the effect of a second-generation motion correction algorithm on the diagnostic accuracy of coronary computed tomography angiography (CCTA) using a 256-detector row CT in patients with increased heart rates.
METHODS: Eighty-one consecutive symptomatic cardiac patients with increased heart rates (≥ 75 beats per min) were enrolled. All patients underwent CCTA and invasive coronary angiography (ICA). CCTA was performed with a 256-detector row CT using prospectively ECG-triggered single-beat protocol. Images were reconstructed using standard (STD) algorithm, first-generation intra-cycle motion correction (MC1) algorithm, and second-generation intra-cycle motion correction (MC2) algorithm. The image quality of coronary artery segments was assessed by two experienced radiologists using a 4-point scale (1: non-diagnostic and 4: excellent), according to the 18-segment model. Diagnostic performance for segments with significant lumen stenosis (≥ 50%) was compared between STD, MC1, and MC2 by using ICA as the reference standard.
RESULTS: The mean effective dose of CCTA was 1.0 mSv. On per-segment level, the overall image quality score and interpretability were improved to 3.56 ± 0.63 and 99.2% due to the use of MC2, as compared to 2.81 ± 0.85 and 92.5% with STD and 3.21 ± 0.79 and 97.2% with MC1. On per-segment level, compared to STD and MC1, MC2 improved the sensitivity (92.2% vs. 79.2%, 80.7%), specificity (97.8% vs. 82.1%, 90.8%), positive predictive value (89.9% vs. 48.4%, 65.1%), negative predictive value (98.3% vs. 94.9%, 95.7%), and diagnostic accuracy (96.8% vs. 81.5%, 89.0%).
CONCLUSION: A second-generation intra-cycle motion correction algorithm for single-beat CCTA significantly improves image quality and diagnostic accuracy in patients with increased heart rate. KEY POINTS: • A second-generation motion correction (MC2) algorithm can further improve the image quality of all coronary arteries than a first-generation motion correction (MC1). • MC2 algorithm can significantly reduce the number of false positive segments compared to standard and MC1 algorithm.

Entities:  

Keywords:  Coronary angiography; Coronary vessels; Heart rate; Motion; Tomography, X-ray computed

Mesh:

Year:  2019        PMID: 30617487     DOI: 10.1007/s00330-018-5929-6

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  33 in total

1.  Dual-source CT coronary angiography: image quality, mean heart rate, and heart rate variability.

Authors:  David Matt; Hans Scheffel; Sebastian Leschka; Thomas G Flohr; Borut Marincek; Philipp A Kaufmann; Hatem Alkadhi
Journal:  AJR Am J Roentgenol       Date:  2007-09       Impact factor: 3.959

2.  Impact of a new motion-correction algorithm on image quality of low-dose coronary CT angiography in patients with insufficient heart rate control.

Authors:  Tobias A Fuchs; Julia Stehli; Svetlana Dougoud; Michael Fiechter; Bert-Ram Sah; Ronny R Buechel; Sacha Bull; Oliver Gaemperli; Philipp A Kaufmann
Journal:  Acad Radiol       Date:  2013-12-12       Impact factor: 3.173

3.  Step and shoot coronary CT angiography using 256-slice CT: effect of heart rate and heart rate variability on image quality.

Authors:  D Muenzel; P B Noel; F Dorn; M Dobritz; E J Rummeny; A Huber
Journal:  Eur Radiol       Date:  2011-06-28       Impact factor: 5.315

4.  Effect of a novel vendor-specific motion-correction algorithm on image quality and diagnostic accuracy in persons undergoing coronary CT angiography without rate-control medications.

Authors:  Jonathon Leipsic; Troy M Labounty; Cameron J Hague; G B John Mancini; Julie M O'Brien; David A Wood; Carolyn M Taylor; Ricardo C Cury; James P Earls; Brett G Heilbron; Amr M Ajlan; Gudrun Feuchtner; James K Min
Journal:  J Cardiovasc Comput Tomogr       Date:  2012-04-06

5.  Diagnostic accuracy of dual-source CT coronary angiography: The effect of average heart rate, heart rate variability, and calcium score in a clinical perspective.

Authors:  Long-Jiang Zhang; Sheng-Yong Wu; Jing Wang; Ying Lu; Zhuo-Li Zhang; Shi-Sen Jiang; Chang-Sheng Zhou; Guang-Ming Lu
Journal:  Acta Radiol       Date:  2010-09       Impact factor: 1.990

6.  Multisection CT protocols: sex- and age-specific conversion factors used to determine effective dose from dose-length product.

Authors:  Paul D Deak; Yulia Smal; Willi A Kalender
Journal:  Radiology       Date:  2010-10       Impact factor: 11.105

7.  64-MDCT angiography of the coronary arteries: nationwide survey of patient preparation practice.

Authors:  Pamela T Johnson; John Eng; Harpreet K Pannu; Elliot K Fishman
Journal:  AJR Am J Roentgenol       Date:  2008-03       Impact factor: 3.959

8.  Survey regarding the clinical practice of cardiac CT in Germany: indications, scanning technique and reporting.

Authors:  M H Maurer; B Hamm; M Dewey
Journal:  Rofo       Date:  2009-08-20

9.  Effect of decrease in heart rate variability on the diagnostic accuracy of 64-MDCT coronary angiography.

Authors:  Sebastian Leschka; Hans Scheffel; Lars Husmann; Oliver Gämperli; Borut Marincek; Philipp A Kaufmann; Hatem Alkadhi
Journal:  AJR Am J Roentgenol       Date:  2008-06       Impact factor: 3.959

10.  Dual-source CT: effect of heart rate, heart rate variability, and calcification on image quality and diagnostic accuracy.

Authors:  Harald Brodoefel; Christof Burgstahler; Ilias Tsiflikas; Anja Reimann; Stephen Schroeder; Claus D Claussen; Martin Heuschmid; Andreas F Kopp
Journal:  Radiology       Date:  2008-03-27       Impact factor: 11.105

View more
  3 in total

1.  Performance evaluation of using shorter contrast injection and 70 kVp with deep learning image reconstruction for reduced contrast medium dose and radiation dose in coronary CT angiography for children: a pilot study.

Authors:  Jihang Sun; Haoyan Li; Jianying Li; Yongli Cao; Zuofu Zhou; Michelle Li; Yun Peng
Journal:  Quant Imaging Med Surg       Date:  2021-09

2.  Effect of 320-row CT reconstruction technology on fractional flow reserve derived from coronary CT angiography based on machine learning: single- versus multiple-cardiac periodic images.

Authors:  Ke Shi; Feng-Feng Yang; Nuo Si; Chen-Tao Zhu; Na Li; Xiao-Lin Dong; Yan Guo; Tong Zhang
Journal:  Quant Imaging Med Surg       Date:  2022-06

Review 3.  Diagnostic accuracy of prospectively gated, 128-slice or greater CTCA at high heart rates: a systematic review and meta-analysis.

Authors:  Gordon T W Mander; Karen Dobeli; Caitlin Steffensen; Zachary Munn
Journal:  J Med Radiat Sci       Date:  2021-07-07
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.