Literature DB >> 19255875

Recent developments in wide-detector cardiac computed tomography.

Sang Il Choi1, Richard T George, Karl H Schuleri, Eun Ju Chun, Joao A C Lima, Albert C Lardo.   

Abstract

Multidetector computed tomography (MDCT) using 64 detectors is widely used for cardiac imaging in the clinical setting. Despite promising results, 64-slice MDCT has important limitations for cardiac applications related to detector coverage, which leads to longer scan times, image artifacts, increased radiation and the need for higher contrast doses. The advent of wide or full cardiac coverage with 256- or 320-slice MDCT provides important advantages that can potentially improve the status of these limitations and expand the utility of cardiac MDCT imaging beyond coronary imaging. Additionally, the combination of wide-detectors and multi-energy acquisitions offer interesting possibilities of improved coverage and temporal resolution that may improve plaque characterization as well as viability and perfusion imaging. In this review we will discuss the current status of wide-detector MDCT scanners and their advantages for clinical coronary and ventricular imaging. We will also review examples of wide detector coronary angiography imaging and discuss emerging complementary non-coronary applications that have been enabled by wide-detector MDCT imaging.

Mesh:

Substances:

Year:  2009        PMID: 19255875     DOI: 10.1007/s10554-009-9443-4

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  29 in total

1.  Dual-source CT cardiac imaging: initial experience.

Authors:  Thorsten R C Johnson; Konstantin Nikolaou; Bernd J Wintersperger; Alexander W Leber; Franz von Ziegler; Carsten Rist; Sonja Buhmann; Andreas Knez; Maximilian F Reiser; Christoph R Becker
Journal:  Eur Radiol       Date:  2006-05-13       Impact factor: 5.315

2.  Contrast-enhanced multidetector computed tomography viability imaging after myocardial infarction: characterization of myocyte death, microvascular obstruction, and chronic scar.

Authors:  Albert C Lardo; Marco A S Cordeiro; Caterina Silva; Luciano C Amado; Richard T George; Anastasios P Saliaris; Karl H Schuleri; Veronica R Fernandes; Menekhem Zviman; Saman Nazarian; Henry R Halperin; Katherine C Wu; Joshua M Hare; Joao A C Lima
Journal:  Circulation       Date:  2006-01-24       Impact factor: 29.690

3.  Cardiac imaging at the emergency department is a must! The role of cardiac computed tomography and magnetic resonance imaging in the evaluation of acute chest pain in the emergency department.

Authors:  L H B Baur
Journal:  Int J Cardiovasc Imaging       Date:  2007-11-17       Impact factor: 2.357

4.  Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: improved image quality and reduced radiation dose.

Authors:  James P Earls; Elise L Berman; Bruce A Urban; Charlene A Curry; Judith L Lane; Robert S Jennings; Colin C McCulloch; Jiang Hsieh; John H Londt
Journal:  Radiology       Date:  2008-01-14       Impact factor: 11.105

5.  Dual-source CT coronary angiography: image quality, mean heart rate, and heart rate variability.

Authors:  David Matt; Hans Scheffel; Sebastian Leschka; Thomas G Flohr; Borut Marincek; Philipp A Kaufmann; Hatem Alkadhi
Journal:  AJR Am J Roentgenol       Date:  2007-09       Impact factor: 3.959

Review 6.  Current status and future directions in technical developments of cardiac computed tomography.

Authors:  Mannudeep K Kalra; Thomas J Brady
Journal:  J Cardiovasc Comput Tomogr       Date:  2008-02-20

7.  Multidetector computed tomography myocardial perfusion imaging during adenosine stress.

Authors:  Richard T George; Caterina Silva; Marco A S Cordeiro; Anthony DiPaula; Douglas R Thompson; William F McCarthy; Takashi Ichihara; Joao A C Lima; Albert C Lardo
Journal:  J Am Coll Cardiol       Date:  2006-06-21       Impact factor: 24.094

8.  Narrowing the phase window width in prospectively ECG-gated single heart beat 320-detector row coronary CT angiography.

Authors:  Michael L Steigner; Hansel J Otero; Tianxi Cai; Dimitrios Mitsouras; Leelakrishna Nallamshetty; Amanda G Whitmore; Hale Ersoy; Noah A Levit; Marcelo F Di Carli; Frank J Rybicki
Journal:  Int J Cardiovasc Imaging       Date:  2008-07-29       Impact factor: 2.357

9.  Initial evaluation of coronary images from 320-detector row computed tomography.

Authors:  Frank J Rybicki; Hansel J Otero; Michael L Steigner; Gabriel Vorobiof; Leelakrishna Nallamshetty; Dimitrios Mitsouras; Hale Ersoy; Richard T Mather; Philip F Judy; Tianxi Cai; Karl Coyner; Kurt Schultz; Amanda G Whitmore; Marcelo F Di Carli
Journal:  Int J Cardiovasc Imaging       Date:  2008-03-27       Impact factor: 2.357

10.  Reperfused myocardial infarction: contrast-enhanced 64-Section CT in comparison to MR imaging.

Authors:  Koen Nieman; Michael D Shapiro; Maros Ferencik; Cesar H Nomura; Suhny Abbara; Udo Hoffmann; Herman K Gold; Ik-Kyung Jang; Thomas J Brady; Ricardo C Cury
Journal:  Radiology       Date:  2008-04       Impact factor: 11.105

View more
  18 in total

Review 1.  Coronary CT angiography with low radiation dose.

Authors:  Lei Xu; Zhaoqi Zhang
Journal:  Int J Cardiovasc Imaging       Date:  2010-02       Impact factor: 2.357

Review 2.  CT-based myocardial perfusion imaging-practical considerations: acquisition, image analysis, interpretation, and challenges.

Authors:  Vishal C Mehra; Marietta Ambrose; Carolina Valdiviezo-Schlomp; Karl H Schuleri; Albert C Lardo; Joao A C Lima; Richard T George
Journal:  J Cardiovasc Transl Res       Date:  2011-06-14       Impact factor: 4.132

Review 3.  Advances in myocardial CT perfusion imaging technology.

Authors:  Yan Yi; Zheng-Yu Jin; Yi-Ning Wang
Journal:  Am J Transl Res       Date:  2016-11-15       Impact factor: 4.060

4.  Comparison of radiation dose estimates, image noise, and scan duration in pediatric body imaging for volumetric and helical modes on 320-detector CT and helical mode on 64-detector CT.

Authors:  Jennifer H Johnston; Daniel J Podberesky; Terry T Yoshizumi; Erin Angel; Greta Toncheva; David B Larson; John C Egelhoff; Colin Anderson-Evans; Giao B Nguyen; Alessandra Barelli; Christopher Alsip; Shelia R Salisbury; Donald P Frush
Journal:  Pediatr Radiol       Date:  2013-05-01

5.  320-detector row CT coronary angiography: effects of heart rate and heart rate variability on image quality, diagnostic accuracy and radiation exposure.

Authors:  G Sun; M Li; X-S Jiang; L Li; Z-H Peng; G-Y Li; L Xu
Journal:  Br J Radiol       Date:  2012-02-28       Impact factor: 3.039

6.  Regional dynamics of fractal dimension of the left ventricular endocardium from cine computed tomography images.

Authors:  Ashish Manohar; Lorenzo Rossini; Gabrielle Colvert; Davis M Vigneault; Francisco Contijoch; Marcus Y Chen; Juan C Del Alamo; Elliot R McVeigh
Journal:  J Med Imaging (Bellingham)       Date:  2019-11-08

7.  Why do commercial CT scanners still employ traditional, filtered back-projection for image reconstruction?

Authors:  Xiaochuan Pan; Emil Y Sidky; Michael Vannier
Journal:  Inverse Probl       Date:  2009-01-01       Impact factor: 2.407

8.  Step and shoot coronary CT angiography using 256-slice CT: effect of heart rate and heart rate variability on image quality.

Authors:  D Muenzel; P B Noel; F Dorn; M Dobritz; E J Rummeny; A Huber
Journal:  Eur Radiol       Date:  2011-06-28       Impact factor: 5.315

9.  Prospective gating with 320-MDCT angiography: effect of volume scan length on radiation dose.

Authors:  Atif Khan; Khurram Nasir; Faisal Khosa; Amina Saghir; Sheryar Sarwar; Melvin E Clouse
Journal:  AJR Am J Roentgenol       Date:  2011-02       Impact factor: 3.959

Review 10.  Imaging myocardial angiogenesis.

Authors:  Joanna J Wykrzykowska; Timothy D Henry; John R Lesser; Robert S Schwartz
Journal:  Nat Rev Cardiol       Date:  2009-09-08       Impact factor: 32.419

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.