Abstract

Multidetector computed tomography (MDCT) has rapidly evolved from 4-detector row systems in 1998 to 256-slice and 320-detector row CT systems. With smaller detector element size and faster gantry rotation speed, spatial and temporal resolution of the 64-detector MDCT scanners have made coronary artery imaging a reliable clinical test. Wide-area coverage MDCT, such as the 256-slice and 320-detector row MDCT scanners, has enabled volumetric imaging of the entire heart free of stair-step artifacts at a single time point within one cardiac cycle. It is hoped that these improvements will be realized with greater diagnostic accuracy of CT coronary angiography. Such scanners hold promise in performing a rapid high quality "triple rule-out" test without high contrast load, improved myocardial perfusion imaging, and even four-dimensional CT subtraction angiography. These emerging technical advances and novel applications will continue to change the way we study coronary artery disease beyond detecting luminal stenosis.

Entities:  

Mesh:

Year:  2010        PMID: 20425186      PMCID: PMC2893879          DOI: 10.1007/s11886-009-0075-z

Source DB:  PubMed          Journal:  Curr Cardiol Rep        ISSN: 1523-3782            Impact factor:   2.931


  55 in total

1.  Variability of repeated coronary artery calcium measurements by electron beam tomography.

Authors:  S Achenbach; D Ropers; S Möhlenkamp; A Schmermund; G Muschiol; J Groth; M Kusus; M Regenfus; W G Daniel; R Erbel; W Moshage
Journal:  Am J Cardiol       Date:  2001-01-15       Impact factor: 2.778

2.  Assessment of myocardial perfusion and viability from routine contrast-enhanced 16-detector-row computed tomography of the heart: preliminary results.

Authors:  Konstantin Nikolaou; Javier Sanz; Michael Poon; Bernd J Wintersperger; Bernd Ohnesorge; Teresa Rius; Zahi A Fayad; Maximilian F Reiser; Christoph R Becker
Journal:  Eur Radiol       Date:  2005-03-18       Impact factor: 5.315

Review 3.  MDCT evaluation of the coronary arteries, 2004: how we do it--data acquisition, postprocessing, display, and interpretation.

Authors:  Leo P Lawler; Harpreet K Pannu; Elliot K Fishman
Journal:  AJR Am J Roentgenol       Date:  2005-05       Impact factor: 3.959

4.  Candidate image processing for real-time volumetric CT subtraction angiography.

Authors:  Shinichiro Mori; Masahiro Endo
Journal:  Eur J Radiol       Date:  2006-11-09       Impact factor: 3.528

5.  High-definition multidetector computed tomography for evaluation of coronary artery stents: comparison to standard-definition 64-detector row computed tomography.

Authors:  James K Min; Rajesh V Swaminathan; Melissa Vass; Scott Gallagher; Jonathan W Weinsaft
Journal:  J Cardiovasc Comput Tomogr       Date:  2009-06-12

Review 6.  New advances in cardiac computed tomography.

Authors:  Prasad Guntur Ramkumar; Dimitrios Mitsouras; Charles L Feldman; Peter H Stone; Frank J Rybicki
Journal:  Curr Opin Cardiol       Date:  2009-11       Impact factor: 2.161

7.  Iterative reconstruction technique for reducing body radiation dose at CT: feasibility study.

Authors:  Amy K Hara; Robert G Paden; Alvin C Silva; Jennifer L Kujak; Holly J Lawder; William Pavlicek
Journal:  AJR Am J Roentgenol       Date:  2009-09       Impact factor: 3.959

8.  Iodinated contrast opacification gradients in normal coronary arteries imaged with prospectively ECG-gated single heart beat 320-detector row computed tomography.

Authors:  Michael L Steigner; Dimitrios Mitsouras; Amanda G Whitmore; Hansel J Otero; Chunliang Wang; Orla Buckley; Noah A Levit; Alia Z Hussain; Tianxi Cai; Richard T Mather; Orjan Smedby; Marcelo F DiCarli; Frank J Rybicki
Journal:  Circ Cardiovasc Imaging       Date:  2009-12-31       Impact factor: 7.792

9.  Steroid-responsive large vessel vasculitis: application of whole-brain 320-detector row dynamic volume CT angiography and perfusion.

Authors:  N Yahyavi-Firouz-Abadi; B L Wynn; F J Rybicki; M L Steigner; A Z Hussain; R Mather; E H Hanson; M Ansarinia; W W Orrison
Journal:  AJNR Am J Neuroradiol       Date:  2009-06-25       Impact factor: 3.825

10.  Detection of myocardial infarction by dual-source coronary computed tomography angiography using quantitated myocardial scintigraphy as the reference standard.

Authors:  R Rubinshtein; T D Miller; E E Williamson; J Kirsch; R J Gibbons; A N Primak; C H McCollough; P A Araoz
Journal:  Heart       Date:  2009-02-05       Impact factor: 5.994

View more
  51 in total

Review 1.  Understanding the genetics of coronary artery disease through the lens of noninvasive imaging.

Authors:  Eunice Yang; Jose D Vargas; David A Bluemke
Journal:  Expert Rev Cardiovasc Ther       Date:  2012-01

2.  Scatter correction for full-fan volumetric CT using a stationary beam blocker in a single full scan.

Authors:  Tianye Niu; Lei Zhu
Journal:  Med Phys       Date:  2011-11       Impact factor: 4.071

3.  Shorter delay time reduces interpatient variability in coronary enhancement in coronary CT angiography using the bolus tracking method with 320-row CT.

Authors:  Nobuo Tomizawa; Takeshi Nojo; Masaaki Akahane; Rumiko Torigoe; Shigeru Kiryu; Kuni Ohtomo
Journal:  Int J Cardiovasc Imaging       Date:  2012-04-22       Impact factor: 2.357

Review 4.  Recent advances in medical imaging: anatomical and clinical applications.

Authors:  Bruno Grignon; Laurence Mainard; Matthieu Delion; Claude Hodez; Guillaume Oldrini
Journal:  Surg Radiol Anat       Date:  2012-05-29       Impact factor: 1.246

Review 5.  Contemporary Role of Computational Analysis in Endovascular Treatment for Thoracic Aortic Disease.

Authors:  Guido H W van Bogerijen; Jip L Tolenaar; Michele Conti; Ferdinando Auricchio; Francesco Secchi; Francesco Sardanelli; Frans L Moll; Joost A van Herwaarden; Vincenzo Rampoldi; Santi Trimarchi
Journal:  Aorta (Stamford)       Date:  2013-08-01

Review 6.  High-resolution CT vascular imaging using blood pool contrast agents.

Authors:  Ananth V Annapragada; Eric Hoffman; Abhay Divekar; Efstathios Karathanasis; Ketan B Ghaghada
Journal:  Methodist Debakey Cardiovasc J       Date:  2012-01

7.  Low-dose coronary-CT angiography using step and shoot at any heart rate: comparison of image quality at systole for high heart rate and diastole for low heart rate with a 128-slice dual-source machine.

Authors:  Jean-François Paul; Aude Amato; Adela Rohnean
Journal:  Int J Cardiovasc Imaging       Date:  2012-08-24       Impact factor: 2.357

8.  Patterns of Opacification in Coronary CT Angiography: Contrast Differences and Gradients.

Authors:  Frank J Rybicki; Yu-Hsiang Juan; Sachin S Saboo; Elizabeth George; Rani Bhivasankar; Dimitrios Mitsouras
Journal:  Curr Cardiovasc Imaging Rep       Date:  2014-10-01

9.  Comparison of radiation dose and image quality: 320-MDCT versus 64-MDCT coronary angiography.

Authors:  Atif Khan; Faisal Khosa; Khurram Nasir; Aya Yassin; Melvin E Clouse
Journal:  AJR Am J Roentgenol       Date:  2011-07       Impact factor: 3.959

Review 10.  Assessment of coronary artery disease using coronary computed tomography angiography and biochemical markers.

Authors:  Gitsios Gitsioudis; Hugo A Katus; Grigorios Korosoglou
Journal:  World J Cardiol       Date:  2014-07-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.