Literature DB >> 23143385

The feasibility of halfcycle reconstruction in high heart rates in coronary CT angiography using 320-row CT.

Nobuo Tomizawa1, Kodai Yamamoto, Masaaki Akahane, Rumiko Torigoe, Shigeru Kiryu, Kuni Ohtomo.   

Abstract

Our aim was to investigate when halfcycle reconstruction (HCR) was feasible in patients who were predicted to have a heart rate over 65 bpm in coronary CT angiography (CTA) using 320-row CT. Seventy-four patients who underwent multiple heart beat scanning were included. The time to reach 230 HU at the ascending aorta during the bolus tracking scan was recorded (T230). HCR image and multicycle reconstruction (MCR) image were reconstructed for each patient. Image quality for each coronary segment was rated on a 3-point scale (3: good, 1: poor). For each patient, we determined that a single beat acquisition was feasible for diagnosis (HCR group) when the number of segments graded score 1 in the HCR image was the same or less than that in the MCR image. Otherwise, we included the patients in the MCR group. HCR group and MCR group included 38 and 36 patients, respectively. Regression analysis showed that body height >1.66 m (odds ratio (OR), 5.74; CI 1.59-25.6; p < 0.007), T230 >16 s (OR 3.11; CI 1.07-9.58; p = 0.04), and heart rate ≤72 bpm (OR 3.18; CI 1.11-9.49; p = 0.03) were related with the HCR group. When all three criteria were fulfilled, the calculated probability that MCR would improve image quality was only 7 %. When the heart rate is ≤72 bpm, single heart beat acquisition is feasible for patients with body height >1.66 m and T230 > 16 s in coronary CTA using 320-row CT.

Entities:  

Mesh:

Year:  2012        PMID: 23143385     DOI: 10.1007/s10554-012-0151-0

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  16 in total

1.  Comparative study with a moving heart phantom of the impact of temporal resolution on image quality with two multidetector electrocardiography-gated computed tomography units.

Authors:  Stephan Wicky; Michael Rosol; Udo Hoffmann; Michael Graziano; Kent E Yucel; Thomas J Brady
Journal:  J Comput Assist Tomogr       Date:  2003 May-Jun       Impact factor: 1.826

Review 2.  Intravenous contrast medium administration and scan timing at CT: considerations and approaches.

Authors:  Kyongtae T Bae
Journal:  Radiology       Date:  2010-07       Impact factor: 11.105

3.  Relationship between beat to beat coronary artery motion and image quality in prospectively ECG-gated two heart beat 320-detector row coronary CT angiography.

Authors:  Nobuo Tomizawa; Shuhei Komatsu; Masaaki Akahane; Rumiko Torigoe; Shigeru Kiryu; Kuni Ohtomo
Journal:  Int J Cardiovasc Imaging       Date:  2010-11-30       Impact factor: 2.357

4.  A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association.

Authors:  W G Austen; J E Edwards; R L Frye; G G Gensini; V L Gott; L S Griffith; D C McGoon; M L Murphy; B B Roe
Journal:  Circulation       Date:  1975-04       Impact factor: 29.690

5.  Dual-source CT coronary angiography: image quality, mean heart rate, and heart rate variability.

Authors:  David Matt; Hans Scheffel; Sebastian Leschka; Thomas G Flohr; Borut Marincek; Philipp A Kaufmann; Hatem Alkadhi
Journal:  AJR Am J Roentgenol       Date:  2007-09       Impact factor: 3.959

6.  Simplified calculation of body-surface area.

Authors:  R D Mosteller
Journal:  N Engl J Med       Date:  1987-10-22       Impact factor: 91.245

7.  Coronary image quality of 320-MDCT in patients with heart rates above 65 beats per minute: preliminary experience.

Authors:  Allan B Lee; Dee Nandurkar; Michal E Schneider-Kolsky; Marcus Crossett; Sujith K Seneviratne; James D Cameron; John M Troupis
Journal:  AJR Am J Roentgenol       Date:  2011-06       Impact factor: 3.959

8.  Step and shoot coronary CT angiography using 256-slice CT: effect of heart rate and heart rate variability on image quality.

Authors:  D Muenzel; P B Noel; F Dorn; M Dobritz; E J Rummeny; A Huber
Journal:  Eur Radiol       Date:  2011-06-28       Impact factor: 5.315

9.  Diagnostic accuracy of high-pitch dual-source CT for the assessment of coronary stenoses: first experience.

Authors:  Sebastian Leschka; Paul Stolzmann; Lotus Desbiolles; Stephan Baumueller; Robert Goetti; Thomas Schertler; Hans Scheffel; Andre Plass; Volkmar Falk; Gudrun Feuchtner; Borut Marincek; Hatem Alkadhi
Journal:  Eur Radiol       Date:  2009-09-16       Impact factor: 5.315

10.  Diagnostic accuracy of 320-row multidetector computed tomography coronary angiography in the non-invasive evaluation of significant coronary artery disease.

Authors:  Fleur R de Graaf; Joanne D Schuijf; Joëlla E van Velzen; Lucia J Kroft; Albert de Roos; Johannes H C Reiber; Eric Boersma; Martin J Schalij; Fabrizio Spanó; J Wouter Jukema; Ernst E van der Wall; Jeroen J Bax
Journal:  Eur Heart J       Date:  2010-01-04       Impact factor: 29.983

View more
  4 in total

1.  Coronary CT angiography using the second-generation 320-detector row CT: assessment of image quality and radiation dose in various heart rates compared with the first-generation scanner.

Authors:  Nobuo Tomizawa; Eriko Maeda; Masaaki Akahane; Rumiko Torigoe; Shigeru Kiryu; Kuni Ohtomo
Journal:  Int J Cardiovasc Imaging       Date:  2013-05-17       Impact factor: 2.357

2.  Effect of 320-row CT reconstruction technology on fractional flow reserve derived from coronary CT angiography based on machine learning: single- versus multiple-cardiac periodic images.

Authors:  Ke Shi; Feng-Feng Yang; Nuo Si; Chen-Tao Zhu; Na Li; Xiao-Lin Dong; Yan Guo; Tong Zhang
Journal:  Quant Imaging Med Surg       Date:  2022-06

3.  Locating the Human Cardiac Conduction System Using a 3D Model of Its Nutritious Arteries.

Authors:  Yu Xu; Yukun Peng; Rongmei Qu; Guorong Zheng; Feiyan Feng; Yan Feng; Linying He; Shanli He; Zeyu Li; Chang Liu; Zhaoming Xiao; Jun Ouyang; Jingxing Dai
Journal:  Sci Rep       Date:  2017-03-23       Impact factor: 4.379

4.  Optimized heart rate for 320-row cardiac CT can be feasibly predicted from prescan parameters.

Authors:  Eriko Maeda; Nobuo Tomizawa; Kodai Yamamoto; Shigeaki Kanno; Masaaki Akahane; Kenji Ino; Masae Uehara; Aiko Sakamoto; Toshiaki Semboku; Rumiko Torigoe; Kuni Ohtomo
Journal:  Springerplus       Date:  2015-11-12
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.