Literature DB >> 19238390

Body physique and heart rate variability determine the occurrence of stair-step artefacts in 64-slice CT coronary angiography with prospective ECG-triggering.

Lars Husmann1, Bernhard A Herzog, Nina Burkhard, Fuminari Tatsugami, Ines Valenta, Oliver Gaemperli, Christophe A Wyss, Ulf Landmesser, Philipp A Kaufmann.   

Abstract

The purpose of this study was to describe and characterize the frequency and extent of stair-step artefacts in computed tomography coronary angiography (CTCA) with prospective electrocardiogram (ECG)-triggering and to identify their determinants. One hundred and forty three consecutive patients (55 women, mean age 57 +/- 13 years) underwent 64-slice CTCA using prospective ECG-triggering. Occurrence of stair-step artefacts in CTCA of the thoracic wall and the coronary arteries was determined and maximum offset was measured. If stair-step artefacts occurred in both cases, a difference between thoracic wall and coronary artery offset of 0.6 mm or greater was attributed to additional motion of the heart. Mean effective radiation dose was 2.1 +/- 0.7 mSv (range 1.0-3.5 mSv). Eighty-nine patients (62%) had stair-step artefacts in CTCA of the coronary arteries (mean offset of 1.7 +/- 1.1 mm), while only 77 patients had thoracic wall stair-step artefacts (mean offset of 1.0 +/- 0.3 mm; significantly different, P < 0.001). Stair-step artefacts in CTCA of the thoracic wall were determined by BMI and weight (P < 0.01), while artefacts in CTCA of the coronary arteries were associated with heart rate variability (P < 0.05). Stair-step artefacts in CTCA with prospective ECG-triggering are determined by (a) motion of the entire patient during table travel, particularly in large patients and (b) by motion of the heart, particularly when heart rates are variable.

Entities:  

Mesh:

Year:  2009        PMID: 19238390     DOI: 10.1007/s00330-009-1339-0

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  27 in total

Review 1.  Pitfalls, artifacts, and remedies in multi- detector row CT coronary angiography.

Authors:  Hyun Seok Choi; Byoung Wook Choi; Kyu Ok Choe; Donghoon Choi; Kyung-Jong Yoo; Myoung-In Kim; Jinna Kim
Journal:  Radiographics       Date:  2004 May-Jun       Impact factor: 5.333

2.  A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association.

Authors:  W G Austen; J E Edwards; R L Frye; G G Gensini; V L Gott; L S Griffith; D C McGoon; M L Murphy; B B Roe
Journal:  Circulation       Date:  1975-04       Impact factor: 29.690

3.  Step-and-shoot data acquisition and reconstruction for cardiac x-ray computed tomography.

Authors:  Jiang Hsieh; John Londt; Melissa Vass; Jay Li; Xiangyang Tang; Darin Okerlund
Journal:  Med Phys       Date:  2006-11       Impact factor: 4.071

4.  Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: improved image quality and reduced radiation dose.

Authors:  James P Earls; Elise L Berman; Bruce A Urban; Charlene A Curry; Judith L Lane; Robert S Jennings; Colin C McCulloch; Jiang Hsieh; John H Londt
Journal:  Radiology       Date:  2008-01-14       Impact factor: 11.105

5.  Low-dose computed tomography coronary angiography with prospective triggering: a promise for the future.

Authors:  Philipp A Kaufmann
Journal:  J Am Coll Cardiol       Date:  2008-10-28       Impact factor: 24.094

6.  Radiation dose reduction and coronary assessability of prospective electrocardiogram-gated computed tomography coronary angiography: comparison with retrospective electrocardiogram-gated helical scan.

Authors:  Takao Maruyama; Masanori Takada; Toshiaki Hasuike; Atsushi Yoshikawa; Eiji Namimatsu; Tohru Yoshizumi
Journal:  J Am Coll Cardiol       Date:  2008-10-28       Impact factor: 24.094

7.  Dual-source CT in step-and-shoot mode: noninvasive coronary angiography with low radiation dose.

Authors:  Paul Stolzmann; Sebastian Leschka; Hans Scheffel; Tobias Krauss; Lotus Desbiolles; André Plass; Michele Genoni; Thomas G Flohr; Simon Wildermuth; Borut Marincek; Hatem Alkadhi
Journal:  Radiology       Date:  2008-10       Impact factor: 11.105

Review 8.  Radiation dose to patients from cardiac diagnostic imaging.

Authors:  Andrew J Einstein; Kevin W Moser; Randall C Thompson; Manuel D Cerqueira; Milena J Henzlova
Journal:  Circulation       Date:  2007-09-11       Impact factor: 29.690

9.  Initial evaluation of coronary images from 320-detector row computed tomography.

Authors:  Frank J Rybicki; Hansel J Otero; Michael L Steigner; Gabriel Vorobiof; Leelakrishna Nallamshetty; Dimitrios Mitsouras; Hale Ersoy; Richard T Mather; Philip F Judy; Tianxi Cai; Karl Coyner; Kurt Schultz; Amanda G Whitmore; Marcelo F Di Carli
Journal:  Int J Cardiovasc Imaging       Date:  2008-03-27       Impact factor: 2.357

10.  Efficacy of pre-scan beta-blockade and impact of heart rate on image quality in patients undergoing coronary multidetector computed tomography angiography.

Authors:  Michael D Shapiro; Antonio J Pena; John H Nichols; Stewart Worrell; Fabian Bamberg; Nina Dannemann; Suhny Abbara; Ricardo C Cury; Thomas J Brady; Udo Hoffmann
Journal:  Eur J Radiol       Date:  2007-06-22       Impact factor: 3.528

View more
  13 in total

1.  Letter to the Editor: re: Body physique and heart rate variability determine the occurrence of stair-step artefacts in 64-slice CT coronary angiography with prospective ECG-triggering.

Authors:  Felipe S Torres; Andrew M Crean; Narinder Paul
Journal:  Eur Radiol       Date:  2009-12       Impact factor: 5.315

2.  Prospective helical acquisition for coronary CT angiography.

Authors:  Marc Dewey
Journal:  Int J Cardiovasc Imaging       Date:  2009-11-18       Impact factor: 2.357

3.  Image quality and radiation dose comparison of prospectively triggered low-dose CCTA: 128-slice dual-source high-pitch spiral versus 64-slice single-source sequential acquisition.

Authors:  Jelena R Ghadri; Silke M Küest; Robert Goetti; Michael Fiechter; Aju P Pazhenkottil; Rene N Nkoulou; Felix P Kuhn; Carsten Pietsch; Patrick von Schulthess; Oliver Gaemperli; Christian Templin; Philipp A Kaufmann
Journal:  Int J Cardiovasc Imaging       Date:  2011-07-10       Impact factor: 2.357

4.  Low-dose coronary-CT angiography using step and shoot at any heart rate: comparison of image quality at systole for high heart rate and diastole for low heart rate with a 128-slice dual-source machine.

Authors:  Jean-François Paul; Aude Amato; Adela Rohnean
Journal:  Int J Cardiovasc Imaging       Date:  2012-08-24       Impact factor: 2.357

5.  Step and shoot coronary CT angiography using 256-slice CT: effect of heart rate and heart rate variability on image quality.

Authors:  D Muenzel; P B Noel; F Dorn; M Dobritz; E J Rummeny; A Huber
Journal:  Eur Radiol       Date:  2011-06-28       Impact factor: 5.315

6.  Association between coronary artery calcification using low-dose MDCT coronary angiography and bone mineral density in middle-aged men and women.

Authors:  T Lin; J C Liu; L Y Chang; C W Shen
Journal:  Osteoporos Int       Date:  2010-06-16       Impact factor: 4.507

7.  Coronary computed tomography angiography using prospective electrocardiography-gated axial scans with 64-detector computed tomography: evaluation of stair-step artifacts and padding time.

Authors:  Fumiko Kimura; Tatsuo Umezawa; Tomonari Asano; Ruri Chihara; Naoko Nishi; Shigeyoshi Nishimura; Fumikazu Sakai
Journal:  Jpn J Radiol       Date:  2010-07-27       Impact factor: 2.374

8.  Feasibility of contrast material volume reduction in coronary artery imaging using 320-slice volume CT.

Authors:  Patrick A Hein; Juliane May; Patrik Rogalla; Craig Butler; Bernd Hamm; Alexander Lembcke
Journal:  Eur Radiol       Date:  2009-12-17       Impact factor: 5.315

9.  Optimizing contrast medium injection protocol individually with body weight for high-pitch prospective ECG-triggering coronary CT angiography.

Authors:  Jie Liu; Jianbo Gao; Runze Wu; Yonggao Zhang; Lili Hu; Ping Hou
Journal:  Int J Cardiovasc Imaging       Date:  2013-01-04       Impact factor: 2.357

10.  Reduction of cardiac motion artifact in step-and-shoot coronary CT angiography with third-generation as compared with second-generation dual-source CT scanners.

Authors:  Liang Jin; Ji'an Zhou; Yiyi Gao; Wei Zhao; Ming Li; Zhizhong Wang
Journal:  Diagn Interv Radiol       Date:  2021-07       Impact factor: 2.630

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.