Literature DB >> 21626948

A method for robust segmentation of arbitrarily shaped radiopaque structures in cone-beam CT projections.

Per Rugaard Poulsen1, Walther Fledelius, Paul J Keall, Elisabeth Weiss, Jun Lu, Emily Brackbill, Geoffrey D Hugo.   

Abstract

PURPOSE: Implanted markers are commonly used in radiotherapy for x-ray based target localization. The projected marker position in a series of cone-beam CT (CBCT) projections can be used to estimate the three dimensional (3D) target trajectory during the CBCT acquisition. This has important applications in tumor motion management such as motion inclusive, gating, and tumor tracking strategies. However, for irregularly shaped markers, reliable segmentation is challenged by large variations in the marker shape with projection angle. The purpose of this study was to develop a semiautomated method for robust and reliable segmentation of arbitrarily shaped radiopaque markers in CBCT projections.
METHODS: The segmentation method involved the following three steps: (1) Threshold based segmentation of the marker in three to six selected projections with large angular separation, good marker contrast, and uniform background; (2) construction of a 3D marker model by coalignment and backprojection of the threshold-based segmentations; and (3) construction of marker templates at all imaging angles by projection of the 3D model and use of these templates for template-based segmentation. The versatility of the segmentation method was demonstrated by segmentation of the following structures in the projections from two clinical CBCT scans: (1) Three linear fiducial markers (Visicoil) implanted in or near a lung tumor and (2) an artificial cardiac valve in a lung cancer patient.
RESULTS: Automatic marker segmentation was obtained in more than 99.9% of the cases. The segmentation failed in a few cases where the marker was either close to a structure of similar appearance or hidden behind a dense structure (data cable).
CONCLUSIONS: A robust template-based method for segmentation of arbitrarily shaped radiopaque markers in CBCT projections was developed.

Entities:  

Mesh:

Year:  2011        PMID: 21626948      PMCID: PMC3078162          DOI: 10.1118/1.3555295

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  11 in total

1.  Robustness and precision of an automatic marker detection algorithm for online prostate daily targeting using a standard V-EPID.

Authors:  S Aubin; L Beaulieu; S Pouliot; J Pouliot; R Roy; L M Girouard; N Martel-Brisson; E Vigneault; J Laverdière
Journal:  Med Phys       Date:  2003-07       Impact factor: 4.071

2.  Potential and limitations of the automatic detection of fiducial markers using an amorphous silicon flat-panel imager.

Authors:  D Buck; M Alber; F Nüsslin
Journal:  Phys Med Biol       Date:  2003-03-21       Impact factor: 3.609

3.  Feasibility of automatic marker detection with an a-Si flat-panel imager.

Authors:  A J Nederveen; J J Lagendijk; P Hofman
Journal:  Phys Med Biol       Date:  2001-04       Impact factor: 3.609

4.  Real-time prostate trajectory estimation with a single imager in arc radiotherapy: a simulation study.

Authors:  Per Rugaard Poulsen; Byungchul Cho; Paul J Keall
Journal:  Phys Med Biol       Date:  2009-06-05       Impact factor: 3.609

5.  A method to estimate mean position, motion magnitude, motion correlation, and trajectory of a tumor from cone-beam CT projections for image-guided radiotherapy.

Authors:  Per Rugaard Poulsen; Byungchul Cho; Paul J Keall
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008-12-01       Impact factor: 7.038

6.  Feasibility study using a Ni-Ti stent and electronic portal imaging to localize the prostate during radiotherapy.

Authors:  Jesper Carl; Bente Lund; Erik Hoejkjaer Larsen; Jane Nielsen
Journal:  Radiother Oncol       Date:  2006-01-18       Impact factor: 6.280

7.  Implementation of a new method for dynamic multileaf collimator tracking of prostate motion in arc radiotherapy using a single kV imager.

Authors:  Per Rugaard Poulsen; Byungchul Cho; Amit Sawant; Paul J Keall
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-11-10       Impact factor: 7.038

8.  Four-dimensional cone beam CT with adaptive gantry rotation and adaptive data sampling.

Authors:  Jun Lu; Thomas M Guerrero; Peter Munro; Andrew Jeung; Pai-Chun M Chi; Peter Balter; X Ronald Zhu; Radhe Mohan; Tinsu Pan
Journal:  Med Phys       Date:  2007-09       Impact factor: 4.071

9.  Fast, accurate, and robust automatic marker detection for motion correction based on oblique kV or MV projection image pairs.

Authors:  Pieter Slagmolen; Jeroen Hermans; Frederik Maes; Tom Budiharto; Karin Haustermans; Frank van den Heuvel
Journal:  Med Phys       Date:  2010-04       Impact factor: 4.071

10.  Automatic marker detection and 3D position reconstruction using cine EPID images for SBRT verification.

Authors:  Sang-June Park; Dan Ionascu; Fred Hacker; Harvey Mamon; Ross Berbeco
Journal:  Med Phys       Date:  2009-10       Impact factor: 4.071

View more
  9 in total

1.  Image quality in thoracic 4D cone-beam CT: a sensitivity analysis of respiratory signal, binning method, reconstruction algorithm, and projection angular spacing.

Authors:  Chun-Chien Shieh; John Kipritidis; Ricky T O'Brien; Zdenka Kuncic; Paul J Keall
Journal:  Med Phys       Date:  2014-04       Impact factor: 4.071

2.  A framework for automatic creation of gold-standard rigid 3D-2D registration datasets.

Authors:  Hennadii Madan; Franjo Pernuš; Boštjan Likar; Žiga Špiclin
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-09-21       Impact factor: 2.924

3.  Automatic tracking of arbitrarily shaped implanted markers in kilovoltage projection images: a feasibility study.

Authors:  Rajesh Regmi; D Michael Lovelock; Margie Hunt; Pengpeng Zhang; Hai Pham; Jianping Xiong; Ellen D Yorke; Karyn A Goodman; Andreas Rimner; Hassan Mostafavi; Gig S Mageras
Journal:  Med Phys       Date:  2014-07       Impact factor: 4.071

4.  A Bayesian approach for three-dimensional markerless tumor tracking using kV imaging during lung radiotherapy.

Authors:  Chun-Chien Shieh; Vincent Caillet; Michelle Dunbar; Paul J Keall; Jeremy T Booth; Nicholas Hardcastle; Carol Haddad; Thomas Eade; Ilana Feain
Journal:  Phys Med Biol       Date:  2017-03-21       Impact factor: 3.609

5.  Automated target tracking in kilovoltage images using dynamic templates of fiducial marker clusters.

Authors:  Warren G Campbell; Moyed Miften; Bernard L Jones
Journal:  Med Phys       Date:  2017-02       Impact factor: 4.071

6.  Markerless tumor tracking using short kilovoltage imaging arcs for lung image-guided radiotherapy.

Authors:  Chun-Chien Shieh; Paul J Keall; Zdenka Kuncic; Chen-Yu Huang; Ilana Feain
Journal:  Phys Med Biol       Date:  2015-11-19       Impact factor: 3.609

7.  A longitudinal four-dimensional computed tomography and cone beam computed tomography dataset for image-guided radiation therapy research in lung cancer.

Authors:  Geoffrey D Hugo; Elisabeth Weiss; William C Sleeman; Salim Balik; Paul J Keall; Jun Lu; Jeffrey F Williamson
Journal:  Med Phys       Date:  2017-02-02       Impact factor: 4.071

8.  Robust methods for automatic image-to-world registration in cone-beam CT interventional guidance.

Authors:  H Dang; Y Otake; S Schafer; J W Stayman; G Kleinszig; J H Siewerdsen
Journal:  Med Phys       Date:  2012-10       Impact factor: 4.506

9.  Estimating intrafraction tumor motion during fiducial-based liver stereotactic radiotherapy via an iterative closest point (ICP) algorithm.

Authors:  Wu-Zhou Li; Zhi-Wen Liang; Yi Cao; Ting-Ting Cao; Hong Quan; Zhi-Yong Yang; Qin Li; Zhi-Tao Dai
Journal:  Radiat Oncol       Date:  2019-10-29       Impact factor: 3.481

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.