Literature DB >> 12906201

Robustness and precision of an automatic marker detection algorithm for online prostate daily targeting using a standard V-EPID.

S Aubin1, L Beaulieu, S Pouliot, J Pouliot, R Roy, L M Girouard, N Martel-Brisson, E Vigneault, J Laverdière.   

Abstract

An algorithm for the daily localization of the prostate using implanted markers and a standard video-based electronic portal imaging device (V-EPID) has been tested. Prior to planning, three gold markers were implanted in the prostate of seven patients. The clinical images were acquired with a BeamViewPlus 2.1 V-EPID for each field during the normal course radiotherapy treatment and are used off-line to determine the ability of the automatic marker detection algorithm to adequately and consistently detect the markers. Clinical images were obtained with various dose levels from ranging 2.5 to 75 MU. The algorithm is based on marker attenuation characterization in the portal image and spatial distribution. A total of 1182 clinical images were taken. The results show an average efficiency of 93% for the markers detected individually and 85% for the group of markers. This algorithm accomplishes the detection and validation in 0.20-0.40 s. When the center of mass of the group of implanted markers is used, then all displacements can be corrected to within 1.0 mm in 84% of the cases and within 1.5 mm in 97% of cases. The standard video-based EPID tested provides excellent marker detection capability even with low dose levels. The V-EPID can be used successfully with radiopaque markers and the automatic detection algorithm to track and correct the daily setup deviations due to organ motions.

Entities:  

Mesh:

Year:  2003        PMID: 12906201     DOI: 10.1118/1.1584041

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Prostate intrafraction motion evaluation using kV fluoroscopy during treatment delivery: a feasibility and accuracy study.

Authors:  Justus Adamson; Qiuwen Wu
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

2.  A method for robust segmentation of arbitrarily shaped radiopaque structures in cone-beam CT projections.

Authors:  Per Rugaard Poulsen; Walther Fledelius; Paul J Keall; Elisabeth Weiss; Jun Lu; Emily Brackbill; Geoffrey D Hugo
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

3.  Automated target tracking in kilovoltage images using dynamic templates of fiducial marker clusters.

Authors:  Warren G Campbell; Moyed Miften; Bernard L Jones
Journal:  Med Phys       Date:  2017-02       Impact factor: 4.071

4.  Computed tomography based evaluation of prostatic fiducial marker migration between the periods of insertion and simulation.

Authors:  Taner Arpacı; Gamze Uğurluer; Emine Burçin İspir; Alper Eken; Tuğana Akbaş; Meltem Serin
Journal:  Turk J Urol       Date:  2017-12-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.