Literature DB >> 11324961

Feasibility of automatic marker detection with an a-Si flat-panel imager.

A J Nederveen1, J J Lagendijk, P Hofman.   

Abstract

Here we study automatic detection of implanted gold markers relative to the field boundary in portal images for on-line position verification. Portal images containing 1-2 MU were taken with an amorphous silicon flat-panel imager. The images were obtained with lateral field at 18 MV. Both the detection success rate and the localization accuracy of markers of 1.0 and 1.2 mm diameter were determined with the help of a marker detection method based on a marker extraction kernel. A method for determining a fiducial reference point related to the field boundary was developed. Detection success rates were 0.99, 0.90 and 0.95 for markers of 1.2 mm diameter and 5 mm length, 1.0 mm diameter and 5 mm length and 1.0 mm diameter and 10 mm length respectively. The localization accuracy appeared to be better than 0.3 mm. The reference point could be reproduced with an accuracy equal to 1 pixel (0.5 mm at isocentre) within one fraction. During the first few seconds of a treatment fraction the field edge was not stable, which appeared to be an effect of the motion of the radiation source. Thanks to the use an a-Si flat-panel imager, on-line position verification using implanted gold markers becomes clinically feasible. We can use a clinically acceptable marker diameter as small as 1.0 mm. These markers can be automatically detected in portal images obtained with 1-2 MU relative to a stable reference point related to the field boundary.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11324961     DOI: 10.1088/0031-9155/46/4/321

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

Review 1.  Radiation therapy dose escalation for prostate cancer: a rationale for IMRT.

Authors:  Alan Pollack; Alex Hanlon; Eric M Horwitz; Steven Feigenberg; Robert G Uzzo; Robert A Price
Journal:  World J Urol       Date:  2003-09-05       Impact factor: 4.226

2.  Fast internal marker tracking algorithm for onboard MV and kV imaging systems.

Authors:  W Mao; R D Wiersma; L Xing
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

3.  A method for robust segmentation of arbitrarily shaped radiopaque structures in cone-beam CT projections.

Authors:  Per Rugaard Poulsen; Walther Fledelius; Paul J Keall; Elisabeth Weiss; Jun Lu; Emily Brackbill; Geoffrey D Hugo
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

4.  A fiducial detection algorithm for real-time image guided IMRT based on simultaneous MV and kV imaging.

Authors:  Weihua Mao; Nadeem Riaz; Louis Lee; Rodney Wiersma; Lei Xing
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.