Abstract

PURPOSE: The streak artifacts caused by metal implants have long been recognized as a problem that limits various applications of CT imaging. In this work, the authors propose an iterative metal artifact reduction algorithm based on constrained optimization.
METHODS: After the shape and location of metal objects in the image domain is determined automatically by the binary metal identification algorithm and the segmentation of "metal shadows" in projection domain is done, constrained optimization is used for image reconstruction. It minimizes a predefined function that reflects a priori knowledge of the image, subject to the constraint that the estimated projection data are within a specified tolerance of the available metal-shadow-excluded projection data, with image non-negativity enforced. The minimization problem is solved through the alternation of projection-onto-convex-sets and the steepest gradient descent of the objective function. The constrained optimization algorithm is evaluated with a penalized smoothness objective.
RESULTS: The study shows that the proposed method is capable of significantly reducing metal artifacts, suppressing noise, and improving soft-tissue visibility. It outperforms the FBP-type methods and ART and EM methods and yields artifacts-free images.
CONCLUSIONS: Constrained optimization is an effective way to deal with CT reconstruction with embedded metal objects. Although the method is presented in the context of metal artifacts, it is applicable to general "missing data" image reconstruction problems.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21452707      PMCID: PMC3033877          DOI: 10.1118/1.3533711

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  20 in total

1.  Iterative X-ray Cone-Beam Tomography for Metal Artifact Reduction and Local Region Reconstruction.

Authors: 
Journal:  Microsc Microanal       Date:  1999-01       Impact factor: 4.127

2.  Penalized-likelihood sinogram restoration for computed tomography.

Authors:  Patrick J La Rivière; Junguo Bian; Phillip A Vargas
Journal:  IEEE Trans Med Imaging       Date:  2006-08       Impact factor: 10.048

3.  Iterative deblurring for CT metal artifact reduction.

Authors:  G Wang; D L Snyder; J A O'Sullivan; M W Vannier
Journal:  IEEE Trans Med Imaging       Date:  1996       Impact factor: 10.048

4.  Penalized weighted least-squares image reconstruction for positron emission tomography.

Authors:  J A Fessler
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

5.  An experimental study on the noise properties of x-ray CT sinogram data in Radon space.

Authors:  Jing Wang; Hongbing Lu; Zhengrong Liang; Daria Eremina; Guangxiang Zhang; Su Wang; John Chen; James Manzione
Journal:  Phys Med Biol       Date:  2008-06-03       Impact factor: 3.609

6.  Iterative reconstruction for helical CT: a simulation study.

Authors:  J Nuyts; B De Man; P Dupont; M Defrise; P Suetens; L Mortelmans
Journal:  Phys Med Biol       Date:  1998-04       Impact factor: 3.609

7.  Total hip prosthesis metal-artifact suppression using iterative deblurring reconstruction.

Authors:  D D Robertson; J Yuan; G Wang; M W Vannier
Journal:  J Comput Assist Tomogr       Date:  1997 Mar-Apr       Impact factor: 1.826

8.  Prospects for quantitative computed tomography imaging in the presence of foreign metal bodies using statistical image reconstruction.

Authors:  Jeffrey F Williamson; Bruce R Whiting; Jasenka Benac; Ryan J Murphy; G James Blaine; Joseph A O'Sullivan; David G Politte; Donald L Snyder
Journal:  Med Phys       Date:  2002-10       Impact factor: 4.071

9.  Sinogram preprocessing and binary reconstruction for determination of the shape and location of metal objects in computed tomography (CT).

Authors:  Bowen Meng; Jing Wang; Lei Xing
Journal:  Med Phys       Date:  2010-11       Impact factor: 4.071

10.  Comparing computed tomography localization with daily ultrasound during image-guided radiation therapy for the treatment of prostate cancer: a prospective evaluation.

Authors:  Steven J Feigenberg; Kamen Paskalev; Shawn McNeeley; Eric M Horwitz; Andre Konski; Lu Wang; Charlie Ma; Alan Pollack
Journal:  J Appl Clin Med Phys       Date:  2007-07-23       Impact factor: 2.102

View more
  28 in total

1.  Improved Image Quality in Head and Neck CT Using a 3D Iterative Approach to Reduce Metal Artifact.

Authors:  W Wuest; M S May; M Brand; N Bayerl; A Krauss; M Uder; M Lell
Journal:  AJNR Am J Neuroradiol       Date:  2015-08-13       Impact factor: 3.825

2.  Sequentially reweighted TV minimization for CT metal artifact reduction.

Authors:  Xiaomeng Zhang; Lei Xing
Journal:  Med Phys       Date:  2013-07       Impact factor: 4.071

3.  U-net based metal segmentation on projection domain for metal artifact reduction in dental CT.

Authors:  Mohamed A A Hegazy; Myung Hye Cho; Min Hyoung Cho; Soo Yeol Lee
Journal:  Biomed Eng Lett       Date:  2019-04-29

4.  Frequency split metal artefact reduction in pelvic computed tomography.

Authors:  M M Lell; E Meyer; M Schmid; R Raupach; M S May; M Uder; M Kachelriess
Journal:  Eur Radiol       Date:  2013-03-22       Impact factor: 5.315

5.  High-kVp Assisted Metal Artifact Reduction for X-ray Computed Tomography.

Authors:  Yan Xi; Yannan Jin; Bruno De Man; Ge Wang
Journal:  IEEE Access       Date:  2016-09-16       Impact factor: 3.367

6.  Clinical evaluation of a commercial orthopedic metal artifact reduction tool for CT simulations in radiation therapy.

Authors:  Hua Li; Camille Noel; Haijian Chen; H Harold Li; Daniel Low; Kevin Moore; Paul Klahr; Jeff Michalski; Hiram A Gay; Wade Thorstad; Sasa Mutic
Journal:  Med Phys       Date:  2012-12       Impact factor: 4.071

7.  Convolutional Neural Network Based Metal Artifact Reduction in X-Ray Computed Tomography.

Authors:  Yanbo Zhang; Hengyong Yu
Journal:  IEEE Trans Med Imaging       Date:  2018-06       Impact factor: 10.048

8.  The effects of the orthopedic metal artifact reduction (O-MAR) algorithm on contouring and dosimetry of head and neck radiotherapy patients.

Authors:  Jussi Sillanpaa; Michael Lovelock; Boris Mueller
Journal:  Med Dosim       Date:  2019-07-30       Impact factor: 1.482

9.  Clinical evaluation of the normalized metal artefact reduction algorithm caused by dental fillings in CT.

Authors:  X-Y Gong; E Meyer; X-J Yu; J-H Sun; L-P Sheng; K-H Huang; R-Z Wu
Journal:  Dentomaxillofac Radiol       Date:  2013-02-18       Impact factor: 2.419

10.  Evaluation of a prototype correction algorithm to reduce metal artefacts in flat detector computed tomography of scaphoid fixation screws.

Authors:  Lukas Filli; Magda Marcon; Bernhard Scholz; Maurizio Calcagni; Tim Finkenstädt; Gustav Andreisek; Roman Guggenberger
Journal:  Skeletal Radiol       Date:  2014-08-28       Impact factor: 2.199

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.