Literature DB >> 31456897

U-net based metal segmentation on projection domain for metal artifact reduction in dental CT.

Mohamed A A Hegazy1, Myung Hye Cho1, Min Hyoung Cho1, Soo Yeol Lee1.   

Abstract

Unlike medical computed tomography (CT), dental CT often suffers from severe metal artifacts stemming from high-density materials employed for dental prostheses. Despite the many metal artifact reduction (MAR) methods available for medical CT, those methods do not sufficiently reduce metal artifacts in dental CT images because MAR performance is often compromised by the enamel layer of teeth, whose X-ray attenuation coefficient is not so different from that of prosthetic materials. We propose a deep learning-based metal segmentation method on the projection domain to improve MAR performance in dental CT. We adopted a simplified U-net for metal segmentation on the projection domain without using any information from the metal-artifacts-corrupted CT images. After training the network with the projection data of five patients, we segmented the metal objects on the projection data of other patients using the trained network parameters. With the segmentation results, we corrected the projection data by applying region filling inside the segmented region. We fused two CT images, one from the corrected projection data and the other from the original raw projection data, and then we forward-projected the fused CT image to get the fused projection data. To get the final corrected projection data, we replaced the metal regions in the original projection data with the ones in the fused projection data. To evaluate the efficacy of the proposed segmentation method on MAR, we compared the MAR performance of the proposed segmentation method with a conventional MAR method based on metal segmentation on the CT image domain. For the MAR performance evaluation, we considered the three primary MAR performance metrics: the relative error (REL), the sum of square difference (SSD), and the normalized absolute difference (NAD). The proposed segmentation method improved MAR performances by around 5.7% for REL, 6.8% for SSD, and 8.2% for NAD. The proposed metal segmentation method on the projection domain showed better MAR performance than the conventional segmentation on the CT image domain. We expect that the proposed segmentation method can improve the performance of the existing MAR methods that are based on metal segmentation on the CT image domain.

Entities:  

Keywords:  Deep learning; Dental CT; Metal artifact reduction; Metal segmentation; U-net

Year:  2019        PMID: 31456897      PMCID: PMC6694350          DOI: 10.1007/s13534-019-00110-2

Source DB:  PubMed          Journal:  Biomed Eng Lett        ISSN: 2093-9868


  20 in total

1.  X-ray CT high-density artefact suppression in cryosurgery.

Authors:  Jikun Wei; George A Sandison; Laigao Chen; Yun Liang; Lisa X Xu
Journal:  Phys Med Biol       Date:  2002-12-21       Impact factor: 3.609

Review 2.  A review of factors that affect artifact from metallic hardware on multi-row detector computed tomography.

Authors:  Milliam L Kataoka; Mary G Hochman; Edward K Rodriguez; Pei-Jan Paul Lin; Shigeto Kubo; Vassilios D Raptopolous
Journal:  Curr Probl Diagn Radiol       Date:  2010 Jul-Aug

3.  An adaptive approach to metal artifact reduction in helical computed tomography for radiation therapy treatment planning: experimental and clinical studies.

Authors:  Mehran Yazdi; Mehran Yazdia; Luc Gingras; Luc Beaulieu
Journal:  Int J Radiat Oncol Biol Phys       Date:  2005-07-15       Impact factor: 7.038

4.  Iterative deblurring for CT metal artifact reduction.

Authors:  G Wang; D L Snyder; J A O'Sullivan; M W Vannier
Journal:  IEEE Trans Med Imaging       Date:  1996       Impact factor: 10.048

5.  Metal artifact reduction for clipping and coiling in interventional C-arm CT.

Authors:  D Prell; Y Kyriakou; T Struffert; A Dörfler; W A Kalender
Journal:  AJNR Am J Neuroradiol       Date:  2009-11-26       Impact factor: 3.825

6.  A novel forward projection-based metal artifact reduction method for flat-detector computed tomography.

Authors:  Daniel Prell; Yiannis Kyriakou; Marcel Beister; Willi A Kalender
Journal:  Phys Med Biol       Date:  2009-10-14       Impact factor: 3.609

7.  Dental CT metal artefact reduction based on sequential substitution.

Authors:  S Tohnak; A J H Mehnert; M Mahoney; S Crozier
Journal:  Dentomaxillofac Radiol       Date:  2011-03       Impact factor: 2.419

8.  Prospects for quantitative computed tomography imaging in the presence of foreign metal bodies using statistical image reconstruction.

Authors:  Jeffrey F Williamson; Bruce R Whiting; Jasenka Benac; Ryan J Murphy; G James Blaine; Joseph A O'Sullivan; David G Politte; Donald L Snyder
Journal:  Med Phys       Date:  2002-10       Impact factor: 4.071

9.  Metal artifact reduction in CT using tissue-class modeling and adaptive prefiltering.

Authors:  Matthieu Bal; Lothar Spies
Journal:  Med Phys       Date:  2006-08       Impact factor: 4.071

10.  Metal artifact reduction in x-ray computed tomography (CT) by constrained optimization.

Authors:  Xiaomeng Zhang; Jing Wang; Lei Xing
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

View more
  11 in total

Review 1.  Practical review on photoacoustic computed tomography using curved ultrasound array transducer.

Authors:  Jinge Yang; Seongwook Choi; Chulhong Kim
Journal:  Biomed Eng Lett       Date:  2021-12-19

2.  Comparison of deep learning-based emission-only attenuation correction methods for positron emission tomography.

Authors:  Donghwi Hwang; Seung Kwan Kang; Kyeong Yun Kim; Hongyoon Choi; Jae Sung Lee
Journal:  Eur J Nucl Med Mol Imaging       Date:  2021-12-09       Impact factor: 10.057

Review 3.  Photoacoustic imaging aided with deep learning: a review.

Authors:  Praveenbalaji Rajendran; Arunima Sharma; Manojit Pramanik
Journal:  Biomed Eng Lett       Date:  2021-11-23

Review 4.  Preclinical Voxel-Based Dosimetry in Theranostics: a Review.

Authors:  Arun Gupta; Min Sun Lee; Joong Hyun Kim; Dong Soo Lee; Jae Sung Lee
Journal:  Nucl Med Mol Imaging       Date:  2020-04-19

Review 5.  Pitfalls on PET/CT Due to Artifacts and Instrumentation.

Authors:  Yu-Jung Tsai; Chi Liu
Journal:  Semin Nucl Med       Date:  2021-07-07       Impact factor: 4.446

6.  Current applications and development of artificial intelligence for digital dental radiography.

Authors:  Ramadhan Hardani Putra; Chiaki Doi; Nobuhiro Yoda; Eha Renwi Astuti; Keiichi Sasaki
Journal:  Dentomaxillofac Radiol       Date:  2021-07-08       Impact factor: 2.419

7.  Self-supervised PET Denoising.

Authors:  Si Young Yie; Seung Kwan Kang; Donghwi Hwang; Jae Sung Lee
Journal:  Nucl Med Mol Imaging       Date:  2020-10-20

8.  Synthetic CT generation from weakly paired MR images using cycle-consistent GAN for MR-guided radiotherapy.

Authors:  Seung Kwan Kang; Hyun Joon An; Hyeongmin Jin; Jung-In Kim; Eui Kyu Chie; Jong Min Park; Jae Sung Lee
Journal:  Biomed Eng Lett       Date:  2021-06-19

9.  Automated White Blood Cell Counting in Nailfold Capillary Using Deep Learning Segmentation and Video Stabilization.

Authors:  Byeonghwi Kim; Yuli-Sun Hariyani; Young-Ho Cho; Cheolsoo Park
Journal:  Sensors (Basel)       Date:  2020-12-11       Impact factor: 3.576

10.  Single-pass metal artifact reduction using a dual-layer flat panel detector.

Authors:  Linxi Shi; N Robert Bennett; Amy Shiroma; Mingshan Sun; Jin Zhang; Richard Colbeth; Josh Star-Lack; Minghui Lu; Adam S Wang
Journal:  Med Phys       Date:  2021-08-10       Impact factor: 4.506

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.