Literature DB >> 27891293

High-kVp Assisted Metal Artifact Reduction for X-ray Computed Tomography.

Yan Xi1, Yannan Jin2, Bruno De Man2, Ge Wang1.   

Abstract

In X-ray computed tomography (CT), the presence of metallic parts in patients causes serious artifacts and degrades image quality. Many algorithms were published for metal artifact reduction (MAR) over the past decades with various degrees of success but without a perfect solution. Some MAR algorithms are based on the assumption that metal artifacts are due only to strong beam hardening and may fail in the case of serious photon starvation. Iterative methods handle photon starvation by discarding or underweighting corrupted data, but the results are not always stable and they come with high computational cost. In this paper, we propose a high-kVp-assisted CT scan mode combining a standard CT scan with a few projection views at a high-kVp value to obtain critical projection information near the metal parts. This method only requires minor hardware modifications on a modern CT scanner. Two MAR algorithms are proposed: dual-energy normalized MAR (DNMAR) and high-energy embedded MAR (HEMAR), aiming at situations without and with photon starvation respectively. Simulation results obtained with the CT simulator CatSim demonstrate that the proposed DNMAR and HEMAR methods can eliminate metal artifacts effectively.

Entities:  

Keywords:  Computed tomography; iterative reconstruction; kVp switching; metal artifact reduction

Year:  2016        PMID: 27891293      PMCID: PMC5119548          DOI: 10.1109/ACCESS.2016.2602854

Source DB:  PubMed          Journal:  IEEE Access        ISSN: 2169-3536            Impact factor:   3.367


  29 in total

Review 1.  X-ray computed tomography.

Authors:  Willi A Kalender
Journal:  Phys Med Biol       Date:  2006-06-20       Impact factor: 3.609

Review 2.  Dual energy CT: preliminary observations and potential clinical applications in the abdomen.

Authors:  Anno Graser; Thorsten R C Johnson; Hersh Chandarana; Michael Macari
Journal:  Eur Radiol       Date:  2008-08-02       Impact factor: 5.315

3.  Objective characterization of GE discovery CT750 HD scanner: gemstone spectral imaging mode.

Authors:  Da Zhang; Xinhua Li; Bob Liu
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

4.  Clinical evaluation of normalized metal artifact reduction in kVCT using MVCT prior images (MVCT-NMAR) for radiation therapy treatment planning.

Authors:  Moti Raj Paudel; Marc Mackenzie; B Gino Fallone; Satyapal Rathee
Journal:  Int J Radiat Oncol Biol Phys       Date:  2014-04-18       Impact factor: 7.038

5.  United iterative reconstruction for spectral computed tomography.

Authors:  Yan Xi; Yi Chen; Rongbiao Tang; Jianqi Sun; Jun Zhao
Journal:  IEEE Trans Med Imaging       Date:  2014-07-16       Impact factor: 10.048

6.  Energy Window Optimization for X-Ray K-Edge Tomographic Imaging.

Authors:  Bo Meng; Wenxiang Cong; Yan Xi; Bruno De Man; Ge Wang
Journal:  IEEE Trans Biomed Eng       Date:  2015-03-18       Impact factor: 4.538

7.  Artifacts in CT: recognition and avoidance.

Authors:  Julia F Barrett; Nicholas Keat
Journal:  Radiographics       Date:  2004 Nov-Dec       Impact factor: 5.333

8.  Metal artifact reduction by dual-energy computed tomography using energetic extrapolation: a systematically optimized protocol.

Authors:  Felix G Meinel; Bernhard Bischoff; Qiaowei Zhang; Fabian Bamberg; Maximilian F Reiser; Thorsten R C Johnson
Journal:  Invest Radiol       Date:  2012-07       Impact factor: 6.016

9.  Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation.

Authors:  Fabian Bamberg; Alexander Dierks; Konstantin Nikolaou; Maximilian F Reiser; Christoph R Becker; Thorsten R C Johnson
Journal:  Eur Radiol       Date:  2011-01-20       Impact factor: 5.315

10.  Monoenergetic imaging of dual-energy CT reduces artifacts from implanted metal orthopedic devices in patients with factures.

Authors:  Changsheng Zhou; Yan E Zhao; Song Luo; Hongyuan Shi; Lin Li; Ling Zheng; Long Jiang Zhang; Guangming Lu
Journal:  Acad Radiol       Date:  2011-10       Impact factor: 3.173

View more
  4 in total

1.  Bismuth Nanoparticle and Polyhydroxybutyrate Coatings Enhance the Radiopacity of Absorbable Inferior Vena Cava Filters for Fluoroscopy-Guided Placement and Longitudinal Computed Tomography Monitoring in Pigs.

Authors:  Jossana A Damasco; Steven Y Huang; Joy Vanessa D Perez; John Andrew T Manongdo; Katherine A Dixon; Malea L Williams; Megan C Jacobsen; Roland Barbosa; Gino Martin Canlas; Gouthami Chintalapani; Adam D Melancon; Rick R Layman; Natalie W Fowlkes; Elizabeth M Whitley; Marites P Melancon
Journal:  ACS Biomater Sci Eng       Date:  2022-03-28

Review 2.  A Survey of Dental Caries Segmentation and Detection Techniques.

Authors:  Vincent Majanga; Serestina Viriri
Journal:  ScientificWorldJournal       Date:  2022-04-11

3.  Artefacts at different distances from titanium and zirconia implants in cone-beam computed tomography: effect of tube current and metal artefact reduction.

Authors:  Arthur Xavier Maseti Mancini; Matheus Urias Cruz Santos; Hugo Gaêta-Araujo; Camila Tirapelli; Ruben Pauwels; Christiano Oliveira-Santos
Journal:  Clin Oral Investig       Date:  2021-02-05       Impact factor: 3.573

4.  Estimation of the radiation dose for dental spectral cone-beam CT.

Authors:  Kaan Orhan; Ruben Pauwels; Yi Chen; Dandan Song; Reinhilde Jacobs
Journal:  Dentomaxillofac Radiol       Date:  2021-04-29       Impact factor: 3.525

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.