Literature DB >> 9071303

Total hip prosthesis metal-artifact suppression using iterative deblurring reconstruction.

D D Robertson1, J Yuan, G Wang, M W Vannier.   

Abstract

PURPOSE: CT of total joint prostheses is limited by metal artifact produced mainly by missing projection data. Iterative deblurring reconstruction is less sensitive to missing projection data than filtered backprojection. A software CT simulator was used to compare total hip prosthesis images reconstructed using standard filtered backprojection, filtered backprojection after linear interpolation of missing data, and iterative deblurring.
METHOD: Unilateral and bilateral total hip replacements with metal-backed or all-polyethylene acetabular prostheses were simulated using bone, metal, and polyethylene annuli and circles of metal and water (soft tissue). Material attenuation properties were taken from the literature. The simulation assumed that no X-rays penetrated the metal. Simulated projection data were reconstructed using filtered backprojection, filtered backprojection after linear interpolation of missing data, and iterative deblurring. Visual observations and objective region-of-interest analyses were made.
RESULTS: Even with no X-rays penetrating the metal, iterative deblurring produced almost no visible artifact within the bone or soft tissues. Bone edge detection and sizing were more easily and accurately done from the iterative deblurring images. All reconstruction techniques underestimated bone and water CT attenuation values. Metal artifact was worse for the bilateral or metal-backed prostheses.
CONCLUSION: Iterative deblurring generated nearly metal-artifact-free images in this simulation. Filtered backprojection, even after linear interpolation, produced typical clinical metal-artifact images.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9071303     DOI: 10.1097/00004728-199703000-00024

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  20 in total

1.  Clinical potential of digital linear tomosynthesis imaging of total joint arthroplasty.

Authors:  Tsutomu Gomi; Hiroshi Hirano
Journal:  J Digit Imaging       Date:  2008-09       Impact factor: 4.056

2.  Sequentially reweighted TV minimization for CT metal artifact reduction.

Authors:  Xiaomeng Zhang; Lei Xing
Journal:  Med Phys       Date:  2013-07       Impact factor: 4.071

Review 3.  Iterative reconstruction for coronary CT angiography: finding its way.

Authors:  Jonathon Leipsic; Brett G Heilbron; Cameron Hague
Journal:  Int J Cardiovasc Imaging       Date:  2011-02-27       Impact factor: 2.357

4.  Artifact level produced by different femoral head prostheses in CT imaging: diamond coated silicon nitride as total hip replacement material.

Authors:  Simone P Rodrigues; José M Paiva; Silvia De Francesco; Margarida I Amaral; Filipe J Oliveira; Rui F Silva
Journal:  J Mater Sci Mater Med       Date:  2012-10-07       Impact factor: 3.896

5.  Model-based tomographic reconstruction of objects containing known components.

Authors:  J Webster Stayman; Yoshito Otake; Jerry L Prince; A Jay Khanna; Jeffrey H Siewerdsen
Journal:  IEEE Trans Med Imaging       Date:  2012-05-16       Impact factor: 10.048

6.  Reduction of artefacts caused by hip implants in CT-based attenuation-corrected PET images using 2-D interpolation of a virtual sinogram on an irregular grid.

Authors:  Mehrsima Abdoli; Johan R de Jong; Jan Pruim; Rudi A J O Dierckx; Habib Zaidi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-08-18       Impact factor: 9.236

7.  Metal artifact reduction in x-ray computed tomography (CT) by constrained optimization.

Authors:  Xiaomeng Zhang; Jing Wang; Lei Xing
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

8.  Metal artifact reduction image reconstruction algorithm for CT of implanted metal orthopedic devices: a work in progress.

Authors:  Patrick T Liu; William P Pavlicek; Mary B Peter; Mark J Spangehl; Catherine C Roberts; Robert G Paden
Journal:  Skeletal Radiol       Date:  2009-01-14       Impact factor: 2.199

9.  Clinical evaluation of the normalized metal artefact reduction algorithm caused by dental fillings in CT.

Authors:  X-Y Gong; E Meyer; X-J Yu; J-H Sun; L-P Sheng; K-H Huang; R-Z Wu
Journal:  Dentomaxillofac Radiol       Date:  2013-02-18       Impact factor: 2.419

10.  3D imaging with an isocentric mobile C-arm comparison of image quality with spiral CT.

Authors:  Dorothea Kotsianos; Stefan Wirth; Tanja Fischer; Ekkehard Euler; Clemens Rock; Ulrich Linsenmaier; Klaus Jürgen Pfeifer; Maximilian Reiser
Journal:  Eur Radiol       Date:  2004-04-01       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.