Literature DB >> 21158299

Sinogram preprocessing and binary reconstruction for determination of the shape and location of metal objects in computed tomography (CT).

Bowen Meng1, Jing Wang, Lei Xing.   

Abstract

PURPOSE: To develop a binary image reconstruction method for the autolocalization of metallic object(s) in CT with sparse projections.
METHODS: The authors divide the system into two types of contents: Metal(s) and nonmetal(s). The boundaries of metallic objects are obtained by using a penalized weighted least-squares algorithm with the adequate intensity gradient-controlled. A novel mechanism of "amplifying" the difference between metal(s) and nonmetallic substances is introduced by preprocessing the sinogram data, which is shown to be necessary in dealing with a case with sparse projection data. A series of experimental studies are performed to evaluate the proposed approach.
RESULTS: A novel binary CT image reconstruction formalism is established for the autodetermination of the shape and location of metallic objects in the presence of limited number of projections. Experimental studies reveal that the presented algorithm works well even when the embedded metal object(s) has different shape(s). It is also shown that when the projection data are sparse, a differential manipulation of projection data can greatly facilitate the binary reconstruction process and allow the authors to obtain accurate binary CT images that would otherwise be unattainable.
CONCLUSIONS: Binary CT reconstruction provides a viable method for determining the geometric distribution information of the implanted metal objects in CT imaging.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21158299      PMCID: PMC2980545          DOI: 10.1118/1.3505294

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  19 in total

1.  Respiratory correlated cone beam CT.

Authors:  Jan-Jakob Sonke; Lambert Zijp; Peter Remeijer; Marcel van Herk
Journal:  Med Phys       Date:  2005-04       Impact factor: 4.071

2.  Penalized-likelihood sinogram smoothing for low-dose CT.

Authors:  Patrick J La Rivière
Journal:  Med Phys       Date:  2005-06       Impact factor: 4.071

3.  Optimizing 4D cone-beam CT acquisition protocol for external beam radiotherapy.

Authors:  Tianfang Li; Lei Xing
Journal:  Int J Radiat Oncol Biol Phys       Date:  2006-12-29       Impact factor: 7.038

4.  Penalized weighted least-squares approach to sinogram noise reduction and image reconstruction for low-dose X-ray computed tomography.

Authors:  Jing Wang; Tianfang Li; Hongbing Lu; Zhengrong Liang
Journal:  IEEE Trans Med Imaging       Date:  2006-10       Impact factor: 10.048

5.  Penalized weighted least-squares image reconstruction for positron emission tomography.

Authors:  J A Fessler
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

6.  Iterative image reconstruction for CBCT using edge-preserving prior.

Authors:  Jing Wang; Tianfang Li; Lei Xing
Journal:  Med Phys       Date:  2009-01       Impact factor: 4.071

7.  Noise suppression in scatter correction for cone-beam CT.

Authors:  Lei Zhu; Jing Wang; Lei Xing
Journal:  Med Phys       Date:  2009-03       Impact factor: 4.071

8.  Four-dimensional cone beam CT with adaptive gantry rotation and adaptive data sampling.

Authors:  Jun Lu; Thomas M Guerrero; Peter Munro; Andrew Jeung; Pai-Chun M Chi; Peter Balter; X Ronald Zhu; Radhe Mohan; Tinsu Pan
Journal:  Med Phys       Date:  2007-09       Impact factor: 4.071

9.  Total hip prosthesis metal-artifact suppression using iterative deblurring reconstruction.

Authors:  D D Robertson; J Yuan; G Wang; M W Vannier
Journal:  J Comput Assist Tomogr       Date:  1997 Mar-Apr       Impact factor: 1.826

10.  Imaging of patients having metal implant using X-ray Computed Tomography.

Authors:  Julian J Liu; John E Lutkin
Journal:  J Xray Sci Technol       Date:  2009       Impact factor: 1.535

View more
  4 in total

1.  Ultrafast and scalable cone-beam CT reconstruction using MapReduce in a cloud computing environment.

Authors:  Bowen Meng; Guillem Pratx; Lei Xing
Journal:  Med Phys       Date:  2011-12       Impact factor: 4.071

2.  Sequentially reweighted TV minimization for CT metal artifact reduction.

Authors:  Xiaomeng Zhang; Lei Xing
Journal:  Med Phys       Date:  2013-07       Impact factor: 4.071

3.  Metal artifact reduction in x-ray computed tomography (CT) by constrained optimization.

Authors:  Xiaomeng Zhang; Jing Wang; Lei Xing
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

4.  Deep Sinogram Completion With Image Prior for Metal Artifact Reduction in CT Images.

Authors:  Lequan Yu; Zhicheng Zhang; Xiaomeng Li; Lei Xing
Journal:  IEEE Trans Med Imaging       Date:  2020-12-29       Impact factor: 10.048

  4 in total