Imaging of nanoparticles with dual-energy computed tomography.

J L Ducote1, Y Alivov, S Molloi.   

Abstract

A simulation study was performed to determine the feasibility and performance of imaging nanoparticles as contrast agents in dual-energy computed tomography. An analytical simulation model was used to model the relevant signal-to-noise ratio (SNR) in dual-energy imaging for the specific case of a three-material patient phantom consisting of water, calcium hydroxyapatite and contrast agent. Elemental gold and iodine were both considered as contrast agents. Simulations were performed for a range of monoenergetic (20-150 keV) and polyenergetic (20-150 kVp) beam spectra. A reference configuration was defined with beam energies of 80 and 140 kVp to match current clinical practice. The effect of adding a silver filter to the high-energy beam was also studied. A figure of merit (FOM), which normalized the dual-energy SNR to the square root of the patient integral dose, was calculated for all cases. The units of the FOM were keV(-1/2). A simple Rose model of detectability was used to estimate the minimum concentration of either elements needed to be detected (SNR > 5). For monoenergetic beams, the peak FOM of gold was 6.4 × 10(-6) keV(-1/2), while the peak FOM of iodine was 3.1 × 10(-6) keV(-1/2), a factor of approximately 2 greater for gold. For polyenergetic spectra, at the reference energies of 80 and 140 kVp, the FOM for gold and iodine was 1.65 × 10(-6) and 5.0 × 10(-7) keV(-1/2), respectively, a factor of approximately 3.3 greater. Also at these energies, the minimum detectable concentration of gold was estimated to be 58.5 mg mL(-1), while iodine was estimated to be 117.5 mg mL(-1). The results suggest that the imaging of a gold nanoparticle contrast agent is well suited to current conditions used in clinical imaging. The addition of a silver filter of 800 µm further increased the image quality of the gold signal by approximately 50% for the same absorbed dose to the patient.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21386141      PMCID: PMC3153953          DOI: 10.1088/0031-9155/56/7/008

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  30 in total

Review 1.  Vulnerable atherosclerotic plaque: a multifocal disease.

Authors:  Ward Casscells; Morteza Naghavi; James T Willerson
Journal:  Circulation       Date:  2003-04-29       Impact factor: 29.690

Review 2.  Intravascular modalities for detection of vulnerable plaque: current status.

Authors:  Briain D MacNeill; Harry C Lowe; Masamichi Takano; Valentin Fuster; Ik-Kyung Jang
Journal:  Arterioscler Thromb Vasc Biol       Date:  2003-06-12       Impact factor: 8.311

3.  Parametrized x-ray absorption in diagnostic radiology from Monte Carlo calculations: implications for x-ray detector design.

Authors:  J M Boone
Journal:  Med Phys       Date:  1992 Nov-Dec       Impact factor: 4.071

4.  Impact of polychromatic x-ray sources on helical, cone-beam computed tomography and dual-energy methods.

Authors:  Emil Y Sidky; Yu Zou; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2004-06-07       Impact factor: 3.609

5.  Atherosclerotic plaque caps are locally weakened when macrophages density is increased.

Authors:  C L Lendon; M J Davies; G V Born; P D Richardson
Journal:  Atherosclerosis       Date:  1991-03       Impact factor: 5.162

6.  Energy-selective reconstructions in X-ray computerized tomography.

Authors:  R E Alvarez; A Macovski
Journal:  Phys Med Biol       Date:  1976-09       Impact factor: 3.609

7.  [Program for calculating diagnostic x-ray spectra].

Authors:  R Nowotny; A Höfer
Journal:  Rofo       Date:  1985-06

8.  Theoretical optimization of dual-energy x-ray imaging with application to mammography.

Authors:  P C Johns; M J Yaffe
Journal:  Med Phys       Date:  1985 May-Jun       Impact factor: 4.071

9.  AuNP-DG: deoxyglucose-labeled gold nanoparticles as X-ray computed tomography contrast agents for cancer imaging.

Authors:  Bulent Aydogan; Ji Li; Tijana Rajh; Ahmed Chaudhary; Steven J Chmura; Charles Pelizzari; Christian Wietholt; Metin Kurtoglu; Peter Redmond
Journal:  Mol Imaging Biol       Date:  2010-10       Impact factor: 3.488

Review 10.  Clinical imaging of the high-risk or vulnerable atherosclerotic plaque.

Authors:  Z A Fayad; V Fuster
Journal:  Circ Res       Date:  2001-08-17       Impact factor: 17.367

View more
  6 in total

1.  Measurement of breast tissue composition with dual energy cone-beam computed tomography: a postmortem study.

Authors:  Huanjun Ding; Justin L Ducote; Sabee Molloi
Journal:  Med Phys       Date:  2013-06       Impact factor: 4.071

2.  Spectral CT using multiple balanced K-edge filters.

Authors:  Yothin Rakvongthai; William Worstell; Georges El Fakhri; Junguo Bian; Auranuch Lorsakul; Jinsong Ouyang
Journal:  IEEE Trans Med Imaging       Date:  2014-09-19       Impact factor: 10.048

3.  Breast composition measurement with a cadmium-zinc-telluride based spectral computed tomography system.

Authors:  Huanjun Ding; Justin L Ducote; Sabee Molloi
Journal:  Med Phys       Date:  2012-03       Impact factor: 4.071

4.  Optimization of K-edge imaging for vulnerable plaques using gold nanoparticles and energy resolved photon counting detectors: a simulation study.

Authors:  Yahya Alivov; Pavlo Baturin; Huy Q Le; Justin Ducote; Sabee Molloi
Journal:  Phys Med Biol       Date:  2013-12-13       Impact factor: 3.609

5.  Preliminary experimental results from a MARS Micro-CT system.

Authors:  Peng He; Hengyong Yu; Patrick Thayer; Xin Jin; Qiong Xu; James Bennett; Rachael Tappenden; Biao Wei; Aaron Goldstein; Peter Renaud; Anthony Butler; Phillip Butler; Ge Wang
Journal:  J Xray Sci Technol       Date:  2012       Impact factor: 1.535

6.  Quantitative contrast-enhanced spectral mammography based on photon-counting detectors: A feasibility study.

Authors:  Huanjun Ding; Sabee Molloi
Journal:  Med Phys       Date:  2017-06-28       Impact factor: 4.071

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.