Literature DB >> 24334301

Optimization of K-edge imaging for vulnerable plaques using gold nanoparticles and energy resolved photon counting detectors: a simulation study.

Yahya Alivov, Pavlo Baturin, Huy Q Le, Justin Ducote, Sabee Molloi.   

Abstract

We investigated the effect of different imaging parameters, such as dose, beam energy, energy resolution and the number of energy bins, on the image quality of K-edge spectral computed tomography (CT) of gold nanoparticles (GNP) accumulated in an atherosclerotic plaque. A maximum likelihood technique was employed to estimate the concentration of GNP, which served as a targeted intravenous contrast material intended to detect the degree of the plaque's inflammation. The simulation studies used a single-slice parallel beam CT geometry with an x-ray beam energy ranging between 50 and 140 kVp. The synthetic phantoms included small (3 cm in diameter) cylinder and chest (33 × 24 cm(2)) phantoms, where both phantoms contained tissue, calcium and gold. In the simulation studies, GNP quantification and background (calcium and tissue) suppression tasks were pursued. The x-ray detection sensor was represented by an energy resolved photon counting detector (e.g., CdZnTe) with adjustable energy bins. Both ideal and more realistic (12% full width at half maximum (FWHM) energy resolution) implementations of the photon counting detector were simulated. The simulations were performed for the CdZnTe detector with a pixel pitch of 0.5-1 mm, which corresponds to a performance without significant charge sharing and cross-talk effects. The Rose model was employed to estimate the minimum detectable concentration of GNPs. A figure of merit (FOM) was used to optimize the x-ray beam energy (kVp) to achieve the highest signal-to-noise ratio with respect to the patient dose. As a result, the successful identification of gold and background suppression was demonstrated. The highest FOM was observed at the 125 kVp x-ray beam energy. The minimum detectable GNP concentration was determined to be approximately 1.06 µmol mL(-1) (0.21 mg mL(-1)) for an ideal detector and about 2.5 µmol mL(-1) (0.49 mg mL(-1)) for a more realistic (12% FWHM) detector. The studies show the optimal imaging parameters at the lowest patient dose using an energy resolved photon counting detector to image GNP in an atherosclerotic plaque.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24334301      PMCID: PMC3962835          DOI: 10.1088/0031-9155/59/1/135

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  39 in total

Review 1.  Vulnerable atherosclerotic plaque: a multifocal disease.

Authors:  Ward Casscells; Morteza Naghavi; James T Willerson
Journal:  Circulation       Date:  2003-04-29       Impact factor: 29.690

2.  Determining the size and shape dependence of gold nanoparticle uptake into mammalian cells.

Authors:  B Devika Chithrani; Arezou A Ghazani; Warren C W Chan
Journal:  Nano Lett       Date:  2006-04       Impact factor: 11.189

3.  Experimental evaluation of an online gamma-camera imaging of permanent seed implantation (OGIPSI) prototype for partial breast irradiation.

Authors:  Ananth Ravi; Curtis B Caldwell; Jean-Philippe Pignol
Journal:  Med Phys       Date:  2008-06       Impact factor: 4.071

4.  Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomography.

Authors:  J P Schlomka; E Roessl; R Dorscheid; S Dill; G Martens; T Istel; C Bäumer; C Herrmann; R Steadman; G Zeitler; A Livne; R Proksa
Journal:  Phys Med Biol       Date:  2008-07-08       Impact factor: 3.609

5.  Noninvasive in vivo human coronary artery lumen and wall imaging using black-blood magnetic resonance imaging.

Authors:  Z A Fayad; V Fuster; J T Fallon; T Jayasundera; S G Worthley; G Helft; J G Aguinaldo; J J Badimon; S K Sharma
Journal:  Circulation       Date:  2000-08-01       Impact factor: 29.690

6.  Imaging of nanoparticles with dual-energy computed tomography.

Authors:  J L Ducote; Y Alivov; S Molloi
Journal:  Phys Med Biol       Date:  2011-03-08       Impact factor: 3.609

7.  Atherosclerotic plaque composition: analysis with multicolor CT and targeted gold nanoparticles.

Authors:  David P Cormode; Ewald Roessl; Axel Thran; Torjus Skajaa; Ronald E Gordon; Jens-Peter Schlomka; Valentin Fuster; Edward A Fisher; Willem J M Mulder; Roland Proksa; Zahi A Fayad
Journal:  Radiology       Date:  2010-07-28       Impact factor: 11.105

8.  Intracoronary morphology of culprit lesions after reperfusion in acute myocardial infarction: serial angioscopic observations.

Authors:  Y Ueda; M Asakura; A Hirayama; K Komamura; M Hori; K Komada
Journal:  J Am Coll Cardiol       Date:  1996-03-01       Impact factor: 24.094

9.  Size of IgG-opsonized particles determines macrophage response during internalization.

Authors:  M Koval; K Preiter; C Adles; P D Stahl; T H Steinberg
Journal:  Exp Cell Res       Date:  1998-07-10       Impact factor: 3.905

10.  Imaging properties of small-pixel spectroscopic x-ray detectors based on cadmium telluride sensors.

Authors:  Thomas Koenig; Julia Schulze; Marcus Zuber; Kristian Rink; Jochen Butzer; Elias Hamann; Angelica Cecilia; Andreas Zwerger; Alex Fauler; Michael Fiederle; Uwe Oelfke
Journal:  Phys Med Biol       Date:  2012-10-03       Impact factor: 3.609

View more
  5 in total

1.  Cascaded systems analysis of photon counting detectors.

Authors:  J Xu; W Zbijewski; G Gang; J W Stayman; K Taguchi; M Lundqvist; E Fredenberg; J A Carrino; J H Siewerdsen
Journal:  Med Phys       Date:  2014-10       Impact factor: 4.071

2.  Numerical observer for atherosclerotic plaque classification in spectral computed tomography.

Authors:  Auranuch Lorsakul; Georges El Fakhri; William Worstell; Jinsong Ouyang; Yothin Rakvongthai; Andrew F Laine; Quanzheng Li
Journal:  J Med Imaging (Bellingham)       Date:  2016-07-12

3.  Targeted Imaging of Renal Fibrosis Using Antibody-Conjugated Gold Nanoparticles in Renal Artery Stenosis.

Authors:  Xiang-Yang Zhu; Xiangyu Zou; Rahul Mukherjee; Zhicong Yu; Christopher M Ferguson; Wei Zhou; Cynthia H McCollough; Lilach O Lerman
Journal:  Invest Radiol       Date:  2018-10       Impact factor: 6.016

4.  Volumetric CT with sparse detector arrays (and application to Si-strip photon counters).

Authors:  A Sisniega; W Zbijewski; J W Stayman; J Xu; K Taguchi; E Fredenberg; Mats Lundqvist; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2015-11-27       Impact factor: 3.609

5.  Dual-Energy CT Imaging of Tumor Liposome Delivery After Gold Nanoparticle-Augmented Radiation Therapy.

Authors:  Jeffrey R Ashton; Katherine D Castle; Yi Qi; David G Kirsch; Jennifer L West; Cristian T Badea
Journal:  Theranostics       Date:  2018-02-12       Impact factor: 11.600

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.