Spectral CT using multiple balanced K-edge filters.

Yothin Rakvongthai, William Worstell, Georges El Fakhri, Junguo Bian, Auranuch Lorsakul, Jinsong Ouyang.   

Abstract

Our goal is to validate a spectral computed tomography (CT) system design that uses a conventional X-ray source with multiple balanced K-edge filters. By performing a simultaneously synthetic reconstruction in multiple energy bins, we obtained a good agreement between measurements and model expectations for a reasonably complex phantom. We performed simulation and data acquisition on a phantom containing multiple rods of different materials using a NeuroLogica CT scanner. Five balanced K-edge filters including Molybdenum, Cerium, Dysprosium, Erbium, and Tungsten were used separately proximal to the X-ray tube. For each sinogram bin, measured filtered vector can be defined as a product of a transmission matrix, which is determined by the filters and is independent of the imaging object, and energy-binned intensity vector. The energy-binned sinograms were then obtained by inverting the transmission matrix followed by a multiplication of the filter measurement vector. For each energy bin defined by two consecutive K-edges, a synthesized energy-binned attenuation image was obtained using filtered back-projection reconstruction. The reconstructed attenuation coefficients for each rod obtained from the experiment was in good agreement with the corresponding simulated results. Furthermore, the reconstructed attenuation coefficients for a given energy bin, agreed with National Institute of Standards and Technology reference values when beam hardening within the energy bin is small. The proposed cost-effective system design using multiple balanced K-edge filters can be used to perform spectral CT imaging at clinically relevant flux rates using conventional detectors and integrating electronics.

Entities:  

Mesh:

Year:  2014        PMID: 25252276      PMCID: PMC4349342          DOI: 10.1109/TMI.2014.2358561

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  18 in total

Review 1.  Tunable monochromatic X rays: a new paradigm in medicine.

Authors:  Frank E Carroll
Journal:  AJR Am J Roentgenol       Date:  2002-09       Impact factor: 3.959

2.  The upper limits of the SNR in radiography and CT with polyenergetic x-rays.

Authors:  Polad M Shikhaliev
Journal:  Phys Med Biol       Date:  2010-08-24       Impact factor: 3.609

3.  Spektr: a computational tool for x-ray spectral analysis and imaging system optimization.

Authors:  J H Siewerdsen; A M Waese; D J Moseley; S Richard; D A Jaffray
Journal:  Med Phys       Date:  2004-11       Impact factor: 4.071

4.  Quasimonochromatic x-ray computed tomography by the balanced filter method using a conventional x-ray source.

Authors:  Masatoshi Saito
Journal:  Med Phys       Date:  2004-12       Impact factor: 4.071

5.  A hybrid approach to reducing computed tomography metal artifacts in intracavitary brachytherapy.

Authors:  Dan Xia; John C Roeske; Lifeng Yu; Charles A Pelizzari; Arno J Mundt; Xiaochuan Pan
Journal:  Brachytherapy       Date:  2005       Impact factor: 2.362

6.  Experimental spectral measurements of heavy K-edge filtered beams for x-ray computed mammotomography.

Authors:  D J Crotty; R L McKinley; M P Tornai
Journal:  Phys Med Biol       Date:  2007-01-10       Impact factor: 3.609

7.  Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomography.

Authors:  J P Schlomka; E Roessl; R Dorscheid; S Dill; G Martens; T Istel; C Bäumer; C Herrmann; R Steadman; G Zeitler; A Livne; R Proksa
Journal:  Phys Med Biol       Date:  2008-07-08       Impact factor: 3.609

8.  Photon counting spectral CT versus conventional CT: comparative evaluation for breast imaging application.

Authors:  Polad M Shikhaliev; Shannon G Fritz
Journal:  Phys Med Biol       Date:  2011-03-02       Impact factor: 3.609

9.  Modeling the performance of a photon counting x-ray detector for CT: energy response and pulse pileup effects.

Authors:  Katsuyuki Taguchi; Mengxi Zhang; Eric C Frey; Xiaolan Wang; Jan S Iwanczyk; Einar Nygard; Neal E Hartsough; Benjamin M W Tsui; William C Barber
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

10.  Imaging of nanoparticles with dual-energy computed tomography.

Authors:  J L Ducote; Y Alivov; S Molloi
Journal:  Phys Med Biol       Date:  2011-03-08       Impact factor: 3.609

View more
  4 in total

1.  Numerical observer for atherosclerotic plaque classification in spectral computed tomography.

Authors:  Auranuch Lorsakul; Georges El Fakhri; William Worstell; Jinsong Ouyang; Yothin Rakvongthai; Andrew F Laine; Quanzheng Li
Journal:  J Med Imaging (Bellingham)       Date:  2016-07-12

2.  Narrow-Energy-Width CT Based on Multivoltage X-Ray Image Decomposition.

Authors:  Jiaotong Wei; Yan Han; Ping Chen
Journal:  Int J Biomed Imaging       Date:  2017-11-07

3.  K-edge subtraction imaging for coronary angiography with a compact synchrotron X-ray source.

Authors:  Stephanie Kulpe; Martin Dierolf; Eva Braig; Benedikt Günther; Klaus Achterhold; Bernhard Gleich; Julia Herzen; Ernst Rummeny; Franz Pfeiffer; Daniela Pfeiffer
Journal:  PLoS One       Date:  2018-12-10       Impact factor: 3.240

4.  CAMPO Precision128 Max ENERGY Spectrum CT Combined with Multiple Parameters to Evaluate the Benign and Malignant Pleural Effusion.

Authors:  Tianyu Zhang; Cuicui Wu; Zhongtao Li; Yan Ding; Lijuan Wen; Li Wang
Journal:  J Healthc Eng       Date:  2021-02-26       Impact factor: 2.682

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.