Literature DB >> 22635175

Preliminary experimental results from a MARS Micro-CT system.

Peng He1, Hengyong Yu, Patrick Thayer, Xin Jin, Qiong Xu, James Bennett, Rachael Tappenden, Biao Wei, Aaron Goldstein, Peter Renaud, Anthony Butler, Phillip Butler, Ge Wang.   

Abstract

The Medipix All Resolution System (MARS) system is a commercial spectral/multi-energy micro-CT scanner designed and assembled by the MARS Bioimaging, Ltd. in New Zealand. This system utilizes the state-of-the-art Medipix photon-counting, energy-discriminating detector technology developed by a collaboration at European Organization for Nuclear Research (CERN). In this paper, we report our preliminary experimental results using this system, including geometrical alignment, photon energy characterization, protocol optimization, and spectral image reconstruction. We produced our scan datasets with a multi-material phantom, and then applied ordered subset-simultaneous algebraic reconstruction technique (OS-SART) to reconstruct images in different energy ranges and principal component analysis (PCA) to evaluate spectral deviation among the energy ranges.

Entities:  

Mesh:

Year:  2012        PMID: 22635175      PMCID: PMC3789250          DOI: 10.3233/XST-2012-0329

Source DB:  PubMed          Journal:  J Xray Sci Technol        ISSN: 0895-3996            Impact factor:   1.535


  9 in total

1.  Convergence studies on iterative algorithms for image reconstruction.

Authors:  Ming Jiang; Ge Wang
Journal:  IEEE Trans Med Imaging       Date:  2003-05       Impact factor: 10.048

2.  Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomography.

Authors:  J P Schlomka; E Roessl; R Dorscheid; S Dill; G Martens; T Istel; C Bäumer; C Herrmann; R Steadman; G Zeitler; A Livne; R Proksa
Journal:  Phys Med Biol       Date:  2008-07-08       Impact factor: 3.609

Review 3.  Dual energy CT: preliminary observations and potential clinical applications in the abdomen.

Authors:  Anno Graser; Thorsten R C Johnson; Hersh Chandarana; Michael Macari
Journal:  Eur Radiol       Date:  2008-08-02       Impact factor: 5.315

4.  Energy-selective reconstructions in X-ray computerized tomography.

Authors:  R E Alvarez; A Macovski
Journal:  Phys Med Biol       Date:  1976-09       Impact factor: 3.609

5.  A soft-threshold filtering approach for reconstruction from a limited number of projections.

Authors:  Hengyong Yu; Ge Wang
Journal:  Phys Med Biol       Date:  2010-07-07       Impact factor: 3.609

6.  Simultaneous algebraic reconstruction technique (SART): a superior implementation of the art algorithm.

Authors:  A H Andersen; A C Kak
Journal:  Ultrason Imaging       Date:  1984-01       Impact factor: 1.578

7.  MicroCT with energy-resolved photon-counting detectors.

Authors:  X Wang; D Meier; S Mikkelsen; G E Maehlum; D J Wagenaar; B M W Tsui; B E Patt; E C Frey
Journal:  Phys Med Biol       Date:  2011-04-05       Impact factor: 3.609

8.  Imaging of nanoparticles with dual-energy computed tomography.

Authors:  J L Ducote; Y Alivov; S Molloi
Journal:  Phys Med Biol       Date:  2011-03-08       Impact factor: 3.609

9.  Synchrotron-based intra-venous K-edge digital subtraction angiography in a pig model: a feasibility study.

Authors:  Elisabeth Schültke; Stefan Fiedler; Christian Nemoz; Lissa Ogieglo; Michael E Kelly; Paul Crawford; Francois Esteve; Thierry Brochard; Michel Renier; Herwig Requardt; Geraldine Le Duc; Bernhard Juurlink; Kotoo Meguro
Journal:  Eur J Radiol       Date:  2009-02-23       Impact factor: 3.528

  9 in total
  7 in total

Review 1.  New Applications of Cardiac Computed Tomography: Dual-Energy, Spectral, and Molecular CT Imaging.

Authors:  Ibrahim Danad; Zahi A Fayad; Martin J Willemink; James K Min
Journal:  JACC Cardiovasc Imaging       Date:  2015-06

2.  Optimization of K-edge imaging with spectral CT.

Authors:  Peng He; Biao Wei; Wenxiang Cong; Ge Wang
Journal:  Med Phys       Date:  2012-11       Impact factor: 4.071

Review 3.  Cardiac CT Imaging of Plaque Vulnerability: Hype or Hope?

Authors:  Martin J Willemink; Tim Leiner; Pál Maurovich-Horvat
Journal:  Curr Cardiol Rep       Date:  2016-04       Impact factor: 2.931

4.  Energy-discriminative performance of a spectral micro-CT system.

Authors:  Peng He; Hengyong Yu; James Bennett; Paul Ronaldson; Rafidah Zainon; Anthony Butler; Phil Butler; Biao Wei; Ge Wang
Journal:  J Xray Sci Technol       Date:  2013       Impact factor: 1.535

5.  Improving dose calculation accuracy in preclinical radiation experiments using multi-energy element resolved cone-beam CT.

Authors:  Yanqi Huang; Xiaoyu Hu; Yuncheng Zhong; Youfang Lai; Chenyang Shen; Xun Jia
Journal:  Phys Med Biol       Date:  2021-12-06       Impact factor: 3.609

6.  Medipix-based Spectral Micro-CT.

Authors:  Hengyong Yu; Qiong Xu; Peng He; James Bennett; Raja Amir; Bruce Dobbs; Xuanqin Mou; Biao Wei; Anthony Butler; Phillip Butler; Ge Wang
Journal:  CT Li Lun Yu Ying Yong Yan Jiu       Date:  2012-12

7.  Material discrimination based on K-edge characteristics.

Authors:  Peng He; Biao Wei; Peng Feng; Mianyi Chen; Deling Mi
Journal:  Comput Math Methods Med       Date:  2013-11-12       Impact factor: 2.238

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.