Literature DB >> 21242985

Anterior chamber angle imaging with optical coherence tomography.

C K-S Leung1, R N Weinreb.   

Abstract

The technology of optical coherence tomography (OCT) has evolved rapidly from time-domain to spectral-domain and swept-source OCT over the recent years. OCT has become an important tool for assessment of the anterior chamber angle and detection of angle closure. Improvement in image resolution and scan speed of OCT has facilitated a more detailed and comprehensive analysis of the anterior chamber angle. It is now possible to examine Schwalbe's line and Schlemm's canal along with the scleral spur. High-speed imaging allows evaluation of the angle in 360°. With three-dimensional reconstruction, visualization of the iris profiles and the angle configurations is enhanced. This article summarizes the development and application of OCT for anterior chamber angle measurement, detection of angle closure, and investigation of the pathophysiology of primary angle closure.

Mesh:

Year:  2011        PMID: 21242985      PMCID: PMC3178313          DOI: 10.1038/eye.2010.201

Source DB:  PubMed          Journal:  Eye (Lond)        ISSN: 0950-222X            Impact factor:   3.775


  39 in total

1.  Comparisons of anterior segment biometry between Chinese and Caucasians using anterior segment optical coherence tomography.

Authors:  C K Leung; P-M Palmiero; R N Weinreb; H Li; Z Sbeity; S Dorairaj; D Leung; S Liu; J M Liebmann; N Congdon; D S Lam; R Ritch
Journal:  Br J Ophthalmol       Date:  2010-07-07       Impact factor: 4.638

2.  Reproducibility of anterior chamber angle measurements with anterior segment optical coherence tomography.

Authors:  Annelie N Tan; Loes D C Sauren; John de Brabander; Tos T J M Berendschot; Valéria Lima Passos; Carroll A B Webers; Rudy M M A Nuijts; Henny J M Beckers
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-04-04       Impact factor: 4.799

3.  Ultrasound biomicroscopy of anterior segment structures in normal and glaucomatous eyes.

Authors:  C J Pavlin; K Harasiewicz; F S Foster
Journal:  Am J Ophthalmol       Date:  1992-04-15       Impact factor: 5.258

4.  Novel approach for anterior chamber angle analysis: anterior chamber angle detection with edge measurement and identification algorithm (ACADEMIA).

Authors:  Christopher Kai-shun Leung; Wing-ho Yung; Cedric Ka-fai Yiu; Sze-wing Lam; Dexter Yu-lung Leung; Raymond Kwok-kay Tse; Clement Chi-yung Tham; Wai-man Chan; Dennis Shun-chiu Lam
Journal:  Arch Ophthalmol       Date:  2006-10

5.  Comparison of gonioscopy and anterior segment ocular coherence tomography in detecting angle closure in different quadrants of the anterior chamber angle.

Authors:  Lisandro M Sakata; Raghavan Lavanya; David S Friedman; Han T Aung; Hong Gao; Rajesh S Kumar; Paul J Foster; Tin Aung
Journal:  Ophthalmology       Date:  2007-10-04       Impact factor: 12.079

6.  Three-dimensional and high-speed swept-source optical coherence tomography for in vivo investigation of human anterior eye segments.

Authors:  Yoshiaki Yasuno; Violeta Dimitrova Madjarova; Shuichi Makita; Masahiro Akiba; Atsushi Morosawa; Changho Chong; Toru Sakai; Kin-Pui Chan; Masahide Itoh; Toyohiko Yatagai
Journal:  Opt Express       Date:  2005-12-26       Impact factor: 3.894

7.  Anterior chamber angle measurement with anterior segment optical coherence tomography: a comparison between slit lamp OCT and Visante OCT.

Authors:  Christopher Kai-shun Leung; Haitao Li; Robert Neal Weinreb; Jing Liu; Carol Yim Lui Cheung; Ricky Yiu Kwong Lai; Chi Pui Pang; Dennis Shun Chiu Lam
Journal:  Invest Ophthalmol Vis Sci       Date:  2008-04-11       Impact factor: 4.799

8.  Anterior segment optical coherence tomography measurement of anterior chamber depth and angle changes after phacoemulsification and intraocular lens implantation.

Authors:  Raciha Beril Kucumen; Nursal Melda Yenerel; Ebru Gorgun; Destan Nil Kulacoglu; Umut Asli Dinc; Murat Levent Alimgil
Journal:  J Cataract Refract Surg       Date:  2008-10       Impact factor: 3.351

9.  Angle changes before and after cataract surgery assessed by Fourier-domain anterior segment optical coherence tomography.

Authors:  Ming-Cheng Tai; Ke-Hung Chien; Da-Wen Lu; Jiann-Torng Chen
Journal:  J Cataract Refract Surg       Date:  2010-08-09       Impact factor: 3.351

10.  Ultrahigh speed 1050nm swept source/Fourier domain OCT retinal and anterior segment imaging at 100,000 to 400,000 axial scans per second.

Authors:  Benjamin Potsaid; Bernhard Baumann; David Huang; Scott Barry; Alex E Cable; Joel S Schuman; Jay S Duker; James G Fujimoto
Journal:  Opt Express       Date:  2010-09-13       Impact factor: 3.894

View more
  34 in total

1.  Agreement of angle closure assessments between gonioscopy, anterior segment optical coherence tomography and spectral domain optical coherence tomography.

Authors:  Elton Lik Tong Tay; Vernon Khet Yau Yong; Boon Ang Lim; Stelson Sia; Elizabeth Poh Ying Wong; Leonard Wei Leon Yip
Journal:  Int J Ophthalmol       Date:  2015-04-18       Impact factor: 1.779

2.  Optimal number of angle images for calculating anterior angle volume and iris volume measurements.

Authors:  Lauren S Blieden; Alice Z Chuang; Laura A Baker; Nicholas P Bell; Timothy S Fuller; Kimberly A Mankiewicz; Robert M Feldman
Journal:  Invest Ophthalmol Vis Sci       Date:  2015-05       Impact factor: 4.799

3.  Assessment of trabecular meshwork width using swept source optical coherence tomography.

Authors:  Tin A Tun; Mani Baskaran; Ce Zheng; Lisandro M Sakata; Shamira A Perera; Anita S Chan; David S Friedman; Carol Y Cheung; Tin Aung
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-02-23       Impact factor: 3.117

4.  Effect of Angle Narrowing on Sectoral Variation of Anterior Chamber Angle Width: The Chinese American Eye Study.

Authors:  Benjamin Y Xu; Anmol A Pardeshi; Jing Shan; Charles DeBoer; Sasan Moghimi; Grace Richter; Roberta McKean-Cowdin; Rohit Varma
Journal:  Ophthalmol Glaucoma       Date:  2019-12-27

5.  Sectoral variations of iridocorneal angle width and iris volume in Chinese Singaporeans: a swept-source optical coherence tomography study.

Authors:  Tin A Tun; Mani Baskaran; Shamira A Perera; Anita S Chan; Ching-Yu Cheng; Hla M Htoon; Lisandro M Sakata; Carol Y Cheung; Tin Aung
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-04-30       Impact factor: 3.117

6.  Factors influencing the pupillary light reflex in healthy individuals.

Authors:  Sourabh Sharma; Mani Baskaran; Annadata V Rukmini; Monisha E Nongpiur; HlaMyint Htoon; Ching-Yu Cheng; Shamira A Perera; Joshua J Gooley; Tin Aung; Dan Milea
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2016-03-12       Impact factor: 3.117

7.  Two-photon imaging of the mouse eye.

Authors:  Andrew W Johnson; David A Ammar; Malik Y Kahook
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-06-09       Impact factor: 4.799

8.  Repeatability and agreement of two anterior segment OCT in myopic patients before implantable collamer lenses implantation.

Authors:  Xi-Fang Zhang; Meng Li; Yan Shi; Xiu-Hua Wan; Huai-Zhou Wang
Journal:  Int J Ophthalmol       Date:  2020-04-18       Impact factor: 1.779

9.  Reproducibility and Agreement of Anterior Segment Parameter Measurements Obtained Using the CASIA2 and Spectralis OCT2 Optical Coherence Tomography Devices.

Authors:  Benjamin Y Xu; Derek D Mai; Rafaella C Penteado; Luke Saunders; Robert N Weinreb
Journal:  J Glaucoma       Date:  2017-11       Impact factor: 2.503

10.  Ocular Biometric Determinants of Anterior Chamber Angle Width in Chinese Americans: The Chinese American Eye Study.

Authors:  Benjamin Y Xu; Jacob Lifton; Bruce Burkemper; Xuejuan Jiang; Anmol A Pardeshi; Sasan Moghimi; Grace M Richter; Roberta McKean-Cowdin; Rohit Varma
Journal:  Am J Ophthalmol       Date:  2020-07-28       Impact factor: 5.258

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.